志方 唐

Mr. 志方 唐


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
BQBaochuang Qi
Baochuang Qi
CLChuan Li
Chuan Li
XCXingbo Cai
Xingbo Cai
LPLuqiao Pu
Luqiao Pu
MGMinzheng Guo
Minzheng Guo
YXYongqing Xu
Yongqing Xu
Osteonecrosis of the femoral head (ONFH) is a common disabling disease. Copper has positive effects on cells that regulate bone metabolism. However, the relationship between copper metabolism (CM) and steroid-induced ONFH (SONFH) remains unclear. The GSE123568 dataset was downloaded from the Gene Expression Omnibus. The differentially expressed CM-related SONFH genes (DE-CMR-SONFHGs) were identified via differential analysis and weighted gene coexpression network analysis (WGCNA). Receiver operating characteristic (ROC) analysis was performed for the predictive accuracy of key genes. Targeting drugs and the copper death-related genes (CDRGs) relevant to key genes were investigated. The bioinformatics results were confirmed via quantitative real-time polymerase chain reaction (qRT–PCR) and Western blot (WB) analysis. Two out of 106 DE-CMR-SONFHGs were identified as key genes (PNP and SLC2A1), which had diagnostic value in distinguishing SONFH from control samples and were related to various immune cell infiltrations. Eleven PMP-targeting drugs and five SLC2A1-targeting drugs were identified. The qRT–PCR, as well as WB, results confirmed the downregulation PNP and SLC2A1 and high expression of the CDRGs DLD, PDHB, and MTF1, which are closely related to these two key genes. In conclusion, PNP and SLC2A1 were identified as key genes related to SONFH and may provide insights for SONFH treatment.



2 September 2023 in Molecular and Cellular Biochemistry
Verified
Journal Article
Closed access
PDF file
志唐志方 唐
志方 唐
HFHanzhen Feng
Hanzhen Feng
XCXusheng Chen
Xusheng Chen
SSShuiyan Shao
Shuiyan Shao
LCLI CHUAN
LI CHUAN

7 June 2024 in Medicine
Verified
Journal Article
Open access
JLJingyuan Mm Li
Jingyuan Mm Li
志唐志方 唐
志方 唐
FFFanzhe Mm Feng
Fanzhe Mm Feng
JLJinlong Mm Liang
Jinlong Mm Liang
NSNengqi Shao
Nengqi Shao
YCYi Cui
Yi Cui
Background: To elucidate the differences in mechanical performance between a novel axially controlled compression spinal rod (ACCSR) for lumbar spondylolysis (LS) and the common spinal rod (CSR). Methods: A total of 36 ACCSRs and 36 CSRs from the same batch were used in this study, each with a diameter of 6.0 mm. Biomechanical tests were carried out on spinal rods for the ACCSR group and on pedicle screw-rod internal fixation systems for the CSR group. The spinal rod tests were conducted following the guidelines outlined in the American Society for Testing and Materials (ASTM) F 2193, while the pedicle screw-rod internal fixation system tests adhered to ASTM F 1798-97 standards. Results: The stiffness of ACCSR and CSR was 1559.15 ± 50.15 and 3788.86 ± 156.45 N/mm (P < .001). ACCSR’s yield load was 1345.73 (1297.90–1359.97) N, whereas CSR’s was 4046.83 (3805.8–4072.53) N (P = .002). ACCSR’s load in the 2.5 millionth cycle of the fatigue four-point bending test was 320 N. The axial gripping capacity of ACCSR and CSR was 1632.53 ± 165.64 and 1273.62 ± 205.63 N (P = .004). ACCSR’s torsional gripping capacity was 3.45 (3.23–3.47) Nm, while CSR’s was 3.27 (3.07–3.59) Nm (P = .654). The stiffness of the pedicle screws of the ACCSR and CSR group was 783.83 (775.67–798.94) and 773.14 (758.70–783.62) N/mm (P = .085). The yield loads on the pedicle screws of the ACCSR and CSR group was 1345.73 (1297.90–1359.97) and 4046.83 (3805.8–4072.53) N (P = .099). Conclusion: Although ACCSR exhibited lower yield load, stiffness, and fatigue resistance compared to CSR, it demonstrated significantly higher axial gripping capacity and met the stress requirement of the human isthmus. Consequently, ACCSR presents a promising alternative to CSR for LS remediation.