Shanna Bolcen

Mrs. Shanna Bolcen

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2023 in Vaccine
Verified
Journal Article
Open access
ZZZhao-Hua Zhou
Zhao-Hua Zhou
MCMargaret M. Cortese
Margaret M. Cortese
JFJia-Long Fang
Jia-Long Fang
RWRobert Wood
Robert Wood
DHDonna S. Hummell
Donna S. Hummell
SKSteven Kozlowski
Steven Kozlowski
The mechanism for anaphylaxis following mRNA COVID-19 vaccination has been widely debated; understanding this serious adverse event is important for future vaccines of similar design. A mechanism proposed is type I hypersensitivity (i.e., IgE-mediated mast cell degranulation) to polyethylene glycol (PEG). Using an assay that, uniquely, had been previously assessed in patients with anaphylaxis to PEG, our objective was to compare anti-PEG IgE in serum from mRNA COVID-19 vaccine anaphylaxis case-patients and persons vaccinated without allergic reactions. Secondarily, we compared anti-PEG IgG and IgM to assess alternative mechanisms. Selected anaphylaxis case-patients reported to U.S. Vaccine Adverse Event Reporting System December 14, 2020–March 25, 2021 were invited to provide a serum sample. mRNA COVID-19 vaccine study participants with residual serum and no allergic reaction post-vaccination (“controls”) were frequency matched to cases 3:1 on vaccine and dose number, sex and 10-year age category. Anti-PEG IgE was measured using a dual cytometric bead assay (DCBA). Anti-PEG IgG and IgM were measured using two different assays: DCBA and a PEGylated-polystyrene bead assay. Laboratorians were blinded to case/control status. All 20 case-patients were women; 17 had anaphylaxis after dose 1, 3 after dose 2. Thirteen (65 %) were hospitalized and 7 (35 %) were intubated. Time from vaccination to serum collection was longer for case-patients vs controls (post-dose 1: median 105 vs 21 days). Among Moderna recipients, anti-PEG IgE was detected in 1 of 10 (10 %) case-patients vs 8 of 30 (27 %) controls (p = 0.40); among Pfizer-BioNTech recipients, it was detected in 0 of 10 case-patients (0 %) vs 1 of 30 (3 %) controls (p >n 0.99). Anti-PEG IgE quantitative signals followed this same pattern. Neither anti-PEG IgG nor IgM was associated with case status with both assay formats. Our results support that anti-PEG IgE is not a predominant mechanism for anaphylaxis post-mRNA COVID-19 vaccination.

23 October 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
JRJulia C. Rhodes
Julia C. Rhodes
RKRebecca Kahn
Rebecca Kahn
SBShanna Bolcen
Shanna Bolcen
NSNong Shang
Nong Shang
YCYunmi Chung
Yunmi Chung
SSStephanie J. Schrag
Stephanie J. Schrag
Maternal vaccines to prevent infant Group B Streptococcus (GBS) disease have progressed through phase II development and may be licensed based on immunologic endpoints, which have yet to be approved by regulatory authorities. Here we present a multistate case control study to characterize the relationship between serotype-specific anti-capsular polysaccharide (CPS) immunoglobulin G concentrations near birth and infant GBS disease risk reduction. Antibody concentration distributions are significantly lower for cases (n = 643) than controls (n = 2801) and serologic thresholds varied by serotype and age at onset, with 80% serotype-specific protective thresholds ranging from 0.52 to 2.49 mcg/mL for early-onset disease (EOD; <7 days old) and 0.02 to 0.14 mcg/mL for late-onset disease (LOD; 7-89 days old). Our study provides the most robust data to date that protection thresholds vary by serotype and are notably lower for LOD than EOD, thereby informing potential serological endpoints for phase III trials evaluating CPS-based maternal GBS vaccine candidates.

9 November 2023 in Vaccines
Verified
Journal Article
Open access
PDF file
SLStephanie Leung
Stephanie Leung
CCClare Collett
Clare Collett
LALauren Allen
Lauren Allen
SLSuzanna Lim
Suzanna Lim
PMPete Maniatis
Pete Maniatis
AGAndrew GORRINGE
Andrew GORRINGE
The placental transfer of antibodies that mediate bacterial clearance via phagocytes is likely important for protection against invasive group B Streptococcus (GBS) disease. A robust functional assay is essential to determine the immune correlates of protection and assist vaccine development. Using standard reagents, we developed and optimized an opsonophagocytic killing assay (OPKA) where dilutions of test sera were incubated with bacteria, baby rabbit complement (BRC) and differentiated HL60 cells (dHL60) for 30 min. Following overnight incubation, the surviving bacteria were enumerated and the % bacterial survival was calculated relative to serum-negative controls. A reciprocal 50% killing titer was then assigned. The minimal concentrations of anti-capsular polysaccharide (CPS) IgG required for 50% killing were 1.65–3.70 ng/mL (depending on serotype). Inhibition of killing was observed using sera absorbed with homologous CPS but not heterologous CPS, indicating specificity for anti-CPS IgG. The assay performance was examined in an interlaboratory study using residual sera from CPS-conjugate vaccine trials with international partners in the Group B Streptococcus Assay STandardisatiON (GASTON) Consortium. Strong correlations of reported titers between laboratories were observed: ST-Ia r = 0.88, ST-Ib r = 0.91, ST-II r = 0.91, ST-III r = 0.90 and ST-V r = 0.94. The OPKA is an easily transferable assay with accessible standard reagents and will be a valuable tool to assess GBS-specific antibodies in natural immunity and vaccine studies.

14 August 2025 in Human Vaccines & Immunotherapeutics
Verified
Journal Article
Open access
SBShanna Bolcen
Shanna Bolcen
BABailey Alston
Bailey Alston
PPPalak Y. Patel
Palak Y. Patel
YLYikun Li
Yikun Li
PMPanagiotis Maniatis
Panagiotis Maniatis
SVSundaram Ajay Vishwanathan
Sundaram Ajay Vishwanathan
A standardized multiplex immunoassay (MIA) to quantify group B Streptococcus (GBS) anti-capsular polysaccharide (CPS) IgG serum concentrations was adopted by the Group B Streptococcal Assay Standardization (GASTON) consortium as a standardized serological assay with the most immediate applications for facilitating the licensure of GBS vaccines. However, dried blood spot (DBS) samples offer advantages for immunological studies, including cost-effectiveness, ease of transport, and storage. To determine suitability of DBS as an alternative sample matrix to serum in MIA, a contrived GBS seropositive panel, including matched DBS and serum samples, was prepared using established methods. The calculated geometric mean titers of GBS anti-CPS IgG values by individual serotype were compared using a paired t-test to establish serum equivalency. Geometric mean values for the matched panel were assessed via Deming regression for precision, accuracy, and concordance correlation coefficient (CCC). The initial acceptance criterion was set at 0.95 for CCC. Two additional criteria based on confidence intervals of CCC, slope, and intercept were used to determine the necessity of a serotype-specific conversion factor. The paired t-test p-values were >.05 for serum equivalency. For sample matrix concordance, CCC values were >0.95 and met correlation criteria for all serotypes. Conversion factors were applied to four serotypes (II, III, IV, and V) that did not meet the criteria for slope, intercept, or both. This demonstration of equivalency between DBS and serum supports the hypothesis that DBS is a suitable testing matrix from which to elucidate anti-CPS IgG concentrations in seroepidemiological and vaccine evaluation studies.