In this study, a skin gas detection system based on quartz enhanced photoacoustic spectroscopy (QEPAS) with a constant temperature collection chamber and an automatic frequency adjustment function was used to collect and monitor carbon dioxide (CO2) emissions from human skin. The detection element of the system is an on-beam structure assembled by a 30.72 kHz quartz tuning fork (QTF). A laser with a wavelength of 4991.26 cm−1 is emitted (with a wavelength adjustment range of 10 cm−1) to excite the QTF. When the integration time is 365 s, the system can achieve a minimum detection limit (MDL) of 2.6 ppmv. The sensitivity of the system is 636.9 ppmv/V. The gas detection system is used to monitor the concentration of CO2 emissions from different parts of the skin and the same part covered by different cosmetics. The CO2 emission rate is defined as the ratio of the skin gas monitoring time of 25 min to the CO2 concentration variable in the gas chamber (volume of 8 mL). The results were collected from three healthy volunteers. Among the six different parts, the cheeks emitted the fastest rate (the average rate was 365.5 ppmv/min) of CO2, and the thighs emitted the slowest rate (the average rate was 56.4 ppmv/min) of CO2. Comparing the experimental results of the six sites at different times, the order of the CO2 emission rate is identical for all six sites. In the experiments with the three cosmetic products (experimental site: forearm), comparing the CO2 emission rate from clean skin with the CO2 emission rate from cosmetic-covered skin shows that sunscreen is the most breathable, followed by barrier cream, and foundation is the least breathable.
It is important to monitor and assess the growth of micro-organisms under various conditions. Yet, thus far there has been no technique to do this with the required speed and accuracy. This work demonstrates swift and accurate assessment of the concentration of carbon dioxide that is produced by use of a wavelength-modulated tunable diode-laser based absorption spectroscopy (WM-TDLAS). It is shown by experiments on two types of bacteria, Staphylococcus aureus and Candida albicans, that the technique can produce high signal-to-noise-ratio data from bacteria grown in confined spaces and exposed to limited amounts of nutrients that can be used for extraction of growth parameters by fitting of the Gompertz model. By applying the technique to S. aureus bacteria at various temperatures (in the 25°C to 42°C range), it is specifically shown that both the maximum growth rate and the so-called lag time have a strong temperature dependence (under the specific conditions with a maximum of the former at 37°C) that matches conventional models well for bacterial growth. Hence, it is demonstrated that WM-TDLAS monitoring is a user-friendly, non-intrusive, and label-free technique that swiftly, and with high signal-to-noise-ratio, can be used for rapid (on the Hz scale) and accurate assessment of bacterial growth.
10 December 2023 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Highly sensitive and integrated optical multi-band CO2 sensors are significant at the shortwave infrared (SWIR) region and still lack research. A compact CO2 sensor composed of a Au-disk/TiO2-cylinder/Au-film metasurface coated by polyhexamethylene biguanide (PHMB) film, functioning at multi-band resonances as well as having high sensitivity to gas concentrations, is presented. It can be employed as a dual-band narrowband absorber, producing two strongly resonant modes at the SWIR region under a reflection-type framework of linearly polarized incidence. Moreover, the metasurface sensor possesses high refractive index sensitivity of 109.25 pm/ppm at around 1040 nm and 42.57 pm/ppm at around 1330 nm in the range of 200–600 ppm, which is suitable for detecting atmospheric CO2. Furthermore, the numerical results show that the sensitivity increases with a thicker PHMB film and optimizes at a thickness above 600 nm. The physical mechanism reveals that the higher order mode exhibits more extended near-field energy than the lower order mode, resulting in more sensitivity towards the surroundings. The design and results of our investigation show high-quality CO2 sensing performance which functions at dual spectrum bands in the SWIR region and is promising for integrated photonic applications.
This paper presents a method for real-time measurement of in vivo leaves photosynthetic rates using quartz-enhanced photoacoustic spectroscopy (QEPAS) with first-harmonic frequency- locking (1f-locking). A compact gas sensor structure was constructed by integrating an in-plane acoustic micro-resonator (AmR) with a commercial 30.720 kHz quartz tuning fork (QTF). The DFB laser’s output wavelength was locked to the CO2 absorption line at 4991.26 cm−1 via 1f-locking, enabling real-time monitoring of CO2 uptake during leaf photosynthesis. Compared to the scanning mode, the standard deviation (STD) in 1f-locking mode is significantly reduced, with detection sensitivity increased by nearly threefold. The system achieved a 1 s measurement cycle, with detection linearity R2 = 0.999. When the integration time is 127 s, the minimum detection limit (MDL) is 2.44 ppmv. The normalized noise equivalent absorption coefficient (NNEA) is 4.78 × 10−9 cm−1·W·Hz−1/2. Results obtained align with reported photosynthetic rate ranges, validating the system’s feasibility. This system provides a portable, highly sensitive, rapid, and reliable method for leaves photosynthetic rate determination.
A sample-grating distributed Bragg reflector (SG-DBR) laser with 18 preprogrammed channels operating at 1540–1580 nm is characterized and compared for use as a source of tunable diode laser gas absorption spectroscopy. Two gases, CO and , were targeted in this study by direct absorption spectroscopy and wavelength modulation spectroscopy with second-harmonic detection. In addition, the detectability of sample optical thickness is reported. Potential extensions of this research in the future are assessed using the SG-DBR diode laser as a source for tunable diode laser gas absorption spectroscopy.