Kylie de Jager

Dr. Kylie de Jager

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2015 in Scientometrics
Verified
Journal Article
Closed access
PDF file
CCChipo Chimhundu
Chipo Chimhundu
KJKylie de Jager
Kylie de Jager
TDTania Douglas
Tania Douglas

26 October 2021 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Open access
JMJohnny McNulty
Johnny McNulty
KJKylie de Jager
Kylie de Jager
HLHenry T Lancashire
Henry T Lancashire
JGJames Graveston
James Graveston
MBMartin Birchall
Martin Birchall
AVAnne Vanhoestenberghe
Anne Vanhoestenberghe
Total laryngectomy (TL) affects critical functions such as swallowing, coughing and speaking. An artificial, bioengineered larynx (ABL), operated via myoelectric signals, may improve quality of life for TL patients. To evaluate the efficacy of using surface electromyography (sEMG) as a control signal to predict instances of swallowing, coughing and speaking, sEMG was recorded from submental, intercostal and diaphragm muscles. The cohort included TL and control participants. Swallowing, coughing, speaking and movement actions were recorded, and a range of classifiers were investigated for prediction of these actions. Our algorithm achieved F1-scores of 76.0 ± 4.4% (swallows), 93.8 ± 2.8% (coughs) and 70.5 ± 5.4% (speech) for controls, and 67.7 ± 4.4% (swallows), 71.0 ± 9.1% (coughs) and 78.0 ± 3.8% (speech) for TLs, using a random forest (RF) classifier. 75.1 ± 6.9% of swallows were detected within 500 ms of onset in the controls, and 63.1 ± 6.1% in TLs. sEMG can be used to predict critical larynx movements, although a viable ABL requires improvements. Results are particularly encouraging as they encompass a TL cohort. An ABL could alleviate many challenges faced by laryngectomees. This study represents a promising step toward realising such a device.

30 May 2017 in South African Journal of Science
Verified
Journal Article
Open access
PDF file
KJKylie de Jager
Kylie de Jager
CCChipo Chimhundu
Chipo Chimhundu
TSTrust Saidi
Trust Saidi
TDTania S. Douglas
Tania S. Douglas
A characterisation of the medical device development landscape in South Africa would be beneficial for future policy developments that encourage locally developed devices to address local healthcare needs. The landscape was explored through a bibliometric analysis (2000–2013) of relevant scientific papers using co-authorship as an indicator of collaboration. Collaborating institutions thus found were divided into four sectors: academia (A); healthcare (H); industry (I); and science and support (S). A collaboration network was drawn to show the links between the institutions and analysed using network analysis metrics. Centrality measures identified seven dominant local institutions from three sectors. Group densities were used to quantify the extent of collaboration: the A sector collaborated the most extensively both within and between sectors; local collaborations were more prevalent than international collaborations. Translational collaborations (AHI, HIS or AHIS) are considered to be pivotal in fostering medical device innovation that is both relevant and likely to be commercialised. Few such collaborations were found, suggesting room for increased collaboration of these types in South Africa.

23 February 2019 in Scientometrics
Verified
Journal Article
Closed access
PDF file
FSFaatiema Salie
Faatiema Salie
KJKylie de Jager
Kylie de Jager
CDCarsten Dreher
Carsten Dreher
TDTania S. Douglas
Tania S. Douglas

27 July 2023 in Electronics
Verified
Journal Article
Open access
PDF file
PRPRAVEEN Kalarickel Ramakrishnan
PRAVEEN Kalarickel Ramakrishnan
TWTimothy Westwood
Timothy Westwood
TGTomé Magalhães Gouveia
Tomé Magalhães Gouveia
MTMahdi Taani
Mahdi Taani
KJKylie de Jager
Kylie de Jager
NWNatalia Wojtowicz
Natalia Wojtowicz
In this paper, a new approach for capacitance measurement for electrical capacitance tomography (ECT) sensors is proposed. The method is based on the digital processing of the time-domain voltage measurements at the sensor electrodes. Furthermore, a robust capacitance estimation algorithm is developed to convert the measured voltage time-series to inter-electrode capacitances. The proposed measurement technique simplifies the electronic design of the ECT sensor and is suitable for use in applications requiring a compact device with a fast scan time. The accuracy and sensitivity of the method are investigated numerically and experimentally using a prototype sensor. In particular, the sensitivity of the estimated capacitance to measurement noise levels is analyzed in detail. Additionally, an analysis of the parameters that affect the accuracy of estimated capacitances is carried out from which we are able to demonstrate that the method is immune to effects such as stray capacitances between the electrodes and the ground. A prototype sensor with an open curved geometry on a millimeter scale is used to test the method empirically. Experimental results obtained for measurements with mineral oil and water are shown and compared against capacitances obtained using a physics-based forward model of the sensor. The inter-electrode capacitances in the range of tens of femtofarads to a few picofarads are estimated and a close match with the forward model results is obtained.

1 August 2019 in South African Journal of Industrial Engineering
Verified
Journal Article
Open access
PDF file
KJKylie de Jager
Kylie de Jager
CCChipo Chimhundu
Chipo Chimhundu
TSTrust Saidi
Trust Saidi
TDTania S. Douglas
Tania S. Douglas
MEDICAL DEVICE INNOVATION IN SOUTH AFRICA: EVOLUTION OF COLLABORATION NETWORKS (2001-2013)