Optimal results in biomaterial testing and tissue engineering under in vitro conditions can only be expected when the tissue generated resembles the original tissue as closely as possible. However, most of the presently used stagnant cell culture models do not produce the necessary degree of cellular differentiation, since important morphological, physiological, and biochemical characteristics disappear, while atypical features arise. To reach a high degree of cellular differentiation and to optimize the cellular environment, an advanced culture technology allowing the regulation of differentiation on different cellular levels was developed. By the use of tissue carriers, a variety of biomaterials or individually selected scaffolds could be tested for optimal tissue development. The tissue carriers are to be placed in perfusion culture containers, which are constantly supplied with fresh medium to avoid an accumulation of harmful metabolic products. The perfusion of medium creates a constant microenvironment with serum-containing or serum-free media. By this technique, tissues could be used for biomaterial or scaffold testing either in a proliferative or in a postmitotic phase, as is observed during natural development. The present paper summarizes technical developments, physiological parameters, cell biological reactions, and theoretical considerations for an optimal tissue development in the field of perfusion culture.
28 October 1999 in Nephron Experimental Nephrology
An in vitro model was used to investigate the terminal differentiation mechanisms leading from embryonic to adult renal tissue. For these experiments the capsula fibrosa with adherent embryonic tissue was isolated from neonatal rabbit kidneys. These explants were mounted onto special tissue carriers and cultured in medium containing serum for 24 h. During that time collecting duct (CD) cells grew out and formed a monolayered epithelium covering the whole surface of the explant. The carriers were then transferred to perfusion culture containers to obtain an optimal degree of differentiation. A special type of container allowed us to continuously superfuse the epithelia with individual media on the luminal and basal sides. Using this method it became possible to culture embryonic CD epithelia in a fluid gradient for weeks. The epithelia were superfused with standard Iscove’s modified Dulbecco’s medium (IMDM) on the basal side, while IMDM containing additional NaCl was used on the luminal side. In controls IMDM was superfused on both the luminal and basal sides. It was found that the degree of differentiation in the CD epithelia is dependent on the influence of fluid gradient exposure. Perfusion culture under isotonic conditions revealed that less than 5% of cells were immunopositive for principal and intercalated cell features, while epithelia cultured in a luminal-basal gradient showed more than 80% positive cells. Immunoreactivity for characteristic markers started to develop after an unexpectedly long latent period of 3–6 days, then increased continuously during the following 5 days and reached a maximum on day 14. After switching back from the gradient to isotonic culture conditions the immunoreactivity for some markers decreased within 5 days, while other characteristic features remained stable. Thus, differentiation was not only under the control of growth factors but was also regulated by the electrolyte environment.
1 August 2004 in Cellular Physiology and Biochemistry
During kidney development a multitude of tubular portions is formed. Little knowledge is available by which cellbiological mechanism a cluster of embryonic cells is able to generate the three-dimensional structure of a tubule. However, this know-how is most important in tissue engineering approaches such as the generation of an artificial kidney module or for the therapy of renal diseases using stem cells. To obtain cellbiological insights in parenchyme development we elaborate a new technique to generate under in vitro conditions renal tubules derived from the embryonic cortex of neonatal rabbits. The aim of the experiments is to establish a specific extracellular environment allowing optimal three-dimensional development of renal tubules under serum-free culture conditions. In the present paper we demonstrate features of the renal stem cell niche and show their isolation as intact microcompartments for advanced tissue culture. Perfusion culture in containers exhibiting a big dead fluid volume results in the development of a flat collecting duct (CD) epithelium at the surface of the tissue explant. In contrast, by fine-tuning the dead fluid volume within a perfusion culture container by an artificial interstitium made of a polyester fleece shows the generation of tubules. It is an up to date unknown morphogenetic information which tells the cells to form tubular structures.
Tissue factory is a modular system designed to generate artificial tissues under optimal perfusion culture conditions. The microenvironment within the culture containers can be fine-tuned to meet the physiological needs of individual tissues, so that the generation of differentiated three-dimensional tissue constructs becomes possible. An optimal physiological environment is created by modulating a liquid phase as well as an artificial interstitium surrounding the growing construct. An innovative construction principle allows production of tissue culture containers, gas exchangers, and gas expanders at minimal material expenditure. Therefore it will be possible for the first time to produce sterile one-way perfusion culture modules for the generation of artificial tissues. The modules can be used separately as well as in a combined module. The system is designed to provide a possible platform for the standardized production of artificial tissues for future applications in biomedicine.
16 January 2014 in Histochemistry and Cell Biology