Yunbi Liu

Dr. Yunbi Liu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
LZLiming Zhong
Liming Zhong
YCYanlin Chen
Yanlin Chen
XZXiao Zhang
Xiao Zhang
SLShupeng Liu
Shupeng Liu
YWYuankui Wu
Yuankui Wu
WYWei Yang
Wei Yang
Given the complicated relationship between the Magnetic Resonance Imaging (MRI) signals and the attenuation values, the attenuation correction in hybrid Positron Emission Tomography (PET)/MRI systems remains a challenging task. Currently, existing methods are either time-consuming or require sufficient samples to train the models. In this work, an efficient approach for predicting pseudo computed tomography (CT) images from T1- and T2-weighted MRI data with limited data is proposed. The proposed approach uses improved neighborhood anchor regression (INAR) as a baseline method to pre-calculate projected matrices to flexibly predict the pseudo CT patches. Techniques, including the augmentation of the MR/CT dataset, learning of the nonlinear descriptors of MR images, hierarchical search for nearest neighbors, data-driven optimization, and multi-regressor ensemble, are adopted to improve the effectiveness of the proposed approach. In total, 22 healthy subjects were enrolled in the study. The pseudo CT images obtained using INAR with multi-regressor ensemble yielded mean absolute error (MAE) of 92.73 $\pm$ 14.86 HU, peak signal-to-noise ratio of 29.77 $\pm$ 1.63 dB, Pearson linear correlation coefficient of 0.82 $\pm$ 0.05, dice similarity coefficient of 0.81 $\pm$ 0.03, and the relative mean absolute error (rMAE) in PET attenuation correction of 1.30 $\pm$ 0.20% compared with true CT images. Moreover, our proposed INAR method, without any refinement strategies, can achieve considerable results with only seven subjects (MAE 106.89 $\pm$ 14.43, rMAE 1.51 $\pm$ 0.21%). The experiments prove the superior performance of the proposed method over the six innovative methods. Moreover, the proposed method can rapidly generate the pseudo CT images that are suitable for PET attenuation correction.

12 July 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
GCGuangwei Cai
Guangwei Cai
YLYunbi Liu
Yunbi Liu
QFQianjin Feng
Qianjin Feng
RLRui-Hong Liang
Rui-Hong Liang
QZQing-Si Zeng
Qing-Si Zeng
WYWei Yang
Wei Yang
Accurate segmentation of interstitial lung disease (ILD) patterns from computed tomography (CT) images is an essential prerequisite to treatment and follow-up. However, it is highly time-consuming for radiologists to pixel-by-pixel segment ILD patterns from CT scans with hundreds of slices. Consequently, it is hard to obtain large amounts of well-annotated data, which poses a huge challenge for data-driven deep learning-based methods. To alleviate this problem, we propose an end-to-end semi-supervised learning framework for the segmentation of ILD patterns (ESSegILD) from CT images via self-training with selective re-training. The proposed ESSegILD model is trained using a large CT dataset with slice-wise sparse annotations, i.e., only labeling a few slices in each CT volume with ILD patterns. Specifically, we adopt a popular semi-supervised framework, i.e., Mean-Teacher, that consists of a teacher model and a student model and uses consistency regularization to encourage consistent outputs from the two models under different perturbations. Furthermore, we propose introducing the latest self-training technique with a selective re-training strategy to select reliable pseudo-labels generated by the teacher model, which are used to expand training samples to promote the student model during iterative training. By leveraging consistency regularization and self-training with selective re-training, our proposed ESSegILD can effectively utilize unlabeled data from a partially annotated dataset to progressively improve the segmentation performance. Experiments are conducted on a dataset of 67 pneumonia patients with incomplete annotations containing over 11,000 CT images with eight different lung patterns of ILDs, with the results indicating that our proposed method is superior to the state-of-the-art methods.

19 April 2021 in IEEE Access
Verified
Journal Article
Open access
YXYuhua Xi
Yuhua Xi
LZLiming Zhong
Liming Zhong
WXWeijie Xie
Weijie Xie
GQGenggeng Qin
Genggeng Qin
YLYunbi Liu
Yunbi Liu
WYWei Yang
Wei Yang
Locating lung field is a critical and fundamental processing stage in the automated analysis of chest radiographs (CXRs) for pulmonary disorders. During the routine examination of CXRs, using both frontal and lateral CXRs can benefit clinical diagnosis of cardiothoracic and lung diseases. However, the accurate segmentation of lung fields on both frontal and lateral CXRs is still challenging due to the blurry boundary of the lung field on lateral CXRs and the poor generalization ability of the models. Existing deep learning-based methods focused on lung field segmentation on frontal CXRs, and the generalization ability of these methods on the different type of CXRs (e.g., pediatric CXRs) and new lung diseases (e.g., COVID-19) has not been tested. In this paper, a view identification assisted fully convolutional network (VI-FCN) is proposed for the segmentation of lung fields on frontal and lateral CXRs simultaneously. The VI-FCN consists of an FCN branch for lung field segmentation and a view identification branch for identification of the frontal and lateral CXRs and for enhancing the lung field segmentation. To improve the generalization ability of VI-FCN, six public datasets and our frontal and lateral CXRs (over 2000 CXRs) were collected for training. The segmentation of lung fields on the Japanese Society of Radiological Technology (JSRT) dataset yields mean dice similarity coefficient (DSC) of 0.979 ± 0.008, mean Jaccard index ( Ω) of 0.959 ± 0.016, and mean boundary distance (MBD) of 1.023 ± 0.487 mm. Besides, the VI-FCN achieves mean DSC of 0.973 ± 0.010, mean Ω of 0.947 ± 0.018, and mean MBD of 1.923 ± 0.755 mm for the segmentation of lung fields on our lateral CXRs. The experiments demonstrate the superior performance of the proposed VI-FCN over most of existing state-of-the-art methods. Moreover, the proposed VI-FCN achieves promising results on untrained pediatric CXRs and COVID-19 datasets.

16 September 2022
Verified
Book Chapter
Closed access
PDF file
LSLuyue Shi
Luyue Shi
XZXuanye Zhang
Xuanye Zhang
YLYunbi Liu
Yunbi Liu
XHXiaoguang Han
Xiaoguang Han

19 February 2025 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
YLYunbi Liu
Yunbi Liu
DDDong Du
Dong Du
YLYun Liu
Yun Liu
STShengxian Tu
Shengxian Tu
WYWei Yang
Wei Yang
QLQingshan Liu
Qingshan Liu

24 June 2019 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
YLYunbi Liu
Yunbi Liu
WYWei Yang
Wei Yang
GSGuangnan She
Guangnan She
LZLiming Zhong
Liming Zhong
ZYZhaoqiang Yun
Zhaoqiang Yun
WCWufan Chen
Wufan Chen
Background and Objective. When radiologists diagnose lung diseases in chest radiography, they can miss some lung nodules overlapped with ribs or clavicles. Dual-energy subtraction (DES) imaging performs well because it can produce soft tissue images, in which the bone components in chest radiography were almost suppressed but the visibility of nodules and lung vessels was still maintained. However, most routinely available X-ray machines do not possess the DES function. Thus, we presented a data-driven decomposition model to perform virtual DES function for decomposing a single conventional chest radiograph into soft tissue and bone images. Methods. For a given chest radiograph, similar chest radiographs with corresponding DES soft tissue and bone images are selected from the training database as exemplars for decomposition. The corresponding fields between the observed chest radiograph and the exemplars are solved by a hierarchically dense matching algorithm. Then, nonparametric priors of soft tissue and bone components are constructed by sampling image patches from the selected soft tissue and bone images according to the corresponding fields. Finally, these nonparametric priors are integrated into our decomposition model, the energy function of which is efficiently optimized by an iteratively reweighted least-squares scheme (IRLS). Results. The decomposition method is evaluated on a data set of posterior-anterior DES radiography (503 cases), as well as on the JSRT data set. The proposed method can produce soft tissue and bone images similar to those produced by the actual DES system. Conclusions. The proposed method can markedly reduce the visibility of bony structures in chest radiographs and shows potential to enhance diagnosis.