Gijs G. Van Hellemondt

Dr. Gijs G. Van Hellemondt


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2021 in Acta Orthopaedica
Verified
Journal Article
Open access
MSMarieke Scharff-Baauw
Marieke Scharff-Baauw
MHMiranda L Van Hooff
Miranda L Van Hooff
GHGijs G. Van Hellemondt
Gijs G. Van Hellemondt
Paulus Christiaan JuttePaulus Christiaan Jutte
Paulus Christiaan Jutte
SBSjoerd K Bulstra
Sjoerd K Bulstra
MSMaarten Spruit
Maarten Spruit
Background and purpose — Custom triflange acetabular components (CTACs) are suggested as good solutions for large acetabular defects in revision total hip arthroplasty. However, high complication rates have been reported and most studies are of limited quality. This prospective study evaluates the performance of a CTAC in patients with large acetabular defects including pelvic discontinuity. Patients and methods — Prospectively collected data of 49 consecutive patients (50 hips), who underwent an acetabular revision with a CTAC were analyzed. Follow-up (FU) was 2 years. The median age of the patients was 68 years (41–89) and 41 were women. Primary outcomes were re-revision of the CTAC and differences between the modified Oxford Hip Score (mOHS) preoperatively and at 2-year follow-up. Secondary outcomes included several patient-reported outcomes (PROMs), radiological results, complications, and a comparison between hips with and without pelvic discontinuity (PD). Results — 1 patient (1 hip) was lost to the 2-year FU. No CTAC needed re-revision. The preoperative and 2-year FU mOHS were available in 40 hips and improved statistically significantly. All of the other secondary outcomes improved over time. 5 hips (of 45 with radiological 2-year FU) had loosening of screws. 8 hips had complications, including 3 persistent wound leakage, 3 pelvic fractures, and 1 dislocation. The mOHS and complication rate were similar in hips with and without PD. Interpretation — Reconstruction of large acetabular defects with and without PD with this CTAC showed good improvement in patient-reported daily functioning, high patient-reported satisfaction, few complications, and no re-revisions at 2-year FU.

1 June 2020 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
PRPaul J.H. van Rensch
Paul J.H. van Rensch
GHGerjon Hannink
Gerjon Hannink
PHPetra J.C. Heesterbeek
Petra J.C. Heesterbeek
AWAte B. Wymenga
Ate B. Wymenga
GHGijs G. Van Hellemondt
Gijs G. Van Hellemondt

Verified
Journal Article
Open access
PDF file
CHCaspar Hulleman
Caspar Hulleman
TWTommy S. de Windt
Tommy S. de Windt
KVKarin Veerman
Karin Veerman
JGJon H.M. Goosen
Jon H.M. Goosen
FWFrank-Christiaan B. M. Wagenaar
Frank-Christiaan B. M. Wagenaar
GHGijs G. Van Hellemondt
Gijs G. Van Hellemondt
Goal: The purpose of this review is to provide a systematic and comprehensive overview of the available literature on the treatment of an early prosthetic joint infection (PJI) after revision total knee arthroplasty (TKA) and provide treatment guidelines. Methods: This systematic review was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines. The search was conducted using the electronic databases of PubMed, Trip, Cochrane, Embase, LILACS and SciElo. After the inclusion of the relevant articles, we extracted the data and results to compose a treatment algorithm for early and acute PJI after revision TKA. Results: After applying the in- and exclusion criteria, seven articles were included in this systematic review focusing on debridement, antibiotics and implant retention (DAIR) for PJI following revision TKA, of which one was prospective and six were retrospective. All studies were qualified as level IV evidence. Conclusions: The current literature suggests that DAIR is a valid treatment option for early infections after revision TKA with success rates of 50–70%. Repeat DAIR shows success rates of around 50%. Further research should be aimed at predicting successful (repeat/two-stage) DAIRs in larger study populations, antibiotic regimes and the cost effectiveness of a second DAIR after revision TKA.

1 July 2022 in The Bone & Joint Journal
Verified
Journal Article
Open access
KMKelly Mills
Kelly Mills
AWAte B. Wymenga
Ate B. Wymenga
GHGijs G. Van Hellemondt
Gijs G. Van Hellemondt
PHPetra J.C. Heesterbeek
Petra J.C. Heesterbeek
Aims: Both the femoral and tibial component are usually cemented at revision total knee arthroplasty (rTKA), while stems can be added with either cemented or press-fit (hybrid) fixation. The aim of this study was to compare the long-term stability of rTKA with cemented and press-fitted stems, using radiostereometric analysis (RSA). Methods: This is a follow-up of a randomized controlled trial, initially involving 32 patients, of whom 19 (nine cemented, ten hybrid) were available for follow-up ten years postoperatively, when further RSA measurements were made. Micromotion of the femoral and tibial components was assessed using model-based RSA software (RSAcore). The clinical outcome was evaluated using the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), and visual analogue scale (pain and satisfaction). Results: The median total femoral translation and rotation at ten years were 0.39 mm (interquartile range (IQR) 0.20 to 0.54) and 0.59° (IQR 0.46° to 0.73°) for the cemented group and 0.70 mm (IQR 0.15 to 0.77) and 0.78° (IQR 0.47° to 1.43°) for the hybrid group. For the tibial components this was 0.38 mm (IQR 0.33 to 0.85) and 0.98° (IQR 0.38° to 1.34°) for the cemented group and 0.42 mm (IQR 0.30 to 0.52) and 0.72° (IQR 0.62° to 0.82°) for the hybrid group. None of these values were significantly different between the two groups and there were no significant differences between the clinical scores in the two groups at this time. There was only one re-revision, in the hybrid group, for infection and not for aseptic loosening. Conclusion: These results show good long-term fixation with no difference in micromotion and clinical outcome between fully cemented and hybrid fixation in rTKA, which builds on earlier short- to mid-term results. The patients all had type I or II osseous defects, which may in part explain the good results. Cite this article: Bone Joint J 2022;104-B(7):875–883.

24 July 2025 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Open access
Massimo InnocentiMassimo Innocenti
Massimo Innocenti
FLFilippo Leggieri
Filippo Leggieri
SLS.N. Van Laarhoven
S.N. Van Laarhoven
TWTommy de Windt
Tommy de Windt
RCRoberto Civinini
Roberto Civinini
GHGijs G. Van Hellemondt
Gijs G. Van Hellemondt
Purpose: The aim of this systematic review was to evaluate the outcomes and complications associated with technology‐assisted revision total knee arthroplasty (revTKA).Methods: A systematic search of PubMed, EMBASE, Web of Science and the Cochrane Library was conducted from inception to 31 October 2024. The inclusion criteria were experimental or observational studies with ≥10 patients undergoing robotic revTKA, evaluating clinical and/or radiological outcomes and/or complication rates. The exclusion criteria were isolated patellar revision, in vitro studies, letters to the editor, book chapters, conference papers, and studies without accessible full text. Each study was given a quality rating using the methodological index for non‐randomised studies (MINORS). The included studies were divided into those reporting revision from TKA and those from unicompartmental knee arthroplasty (UKA), for both qualitative and quantitative synthesis. Random‐effects meta‐analyses were performed where appropriate. Mean differences with 95% confidence intervals (CIs) were calculated for radiographic parameters. Heterogeneity was assessed using the I2 statistic.Results: Across 20 studies (795 cases), 10 assessed revTKA and 10 examined revUKA. Of the revTKA studies, four were comparative cohorts, while among the revUKA studies, seven were comparative cohorts. Technology‐assisted revTKA showed fewer outliers in hip–knee–ankle angle (13.3% [95% CI, 8.7%–19.0%] vs. 26.1% [95% CI, 16.3%–38.1%]), superior component positioning within ±3° for the lateral distal femoral angle (88.4% [95% CI, 83.2%–92.4%] vs. 79.7% [95% CI, 68.8%–87.5%]) and for the medial proximal tibial angle (91.2% [95% CI, 86.3%–94.6%] vs. 82.6% [95% CI, 72.0%–89.8%]), and better joint line restoration (79.5% vs. 58.3% within 4 mm). Procedures required an additional 15–24 min. Complication rates were comparable between groups. For UKA revisions, outcomes were generally similar between technology‐assisted and conventional techniques, with mixed results on alignment accuracy and clinical scores.Conclusion: Technology‐assisted revTKA achieves optimal alignment parameters and reduces the occurrence of outliers compared with conventional techniques. However, these radiographic improvements do not consistently translate into enhanced clinical outcomes or reduced complication rates.Level of Evidence: Level IV.

20 February 2023 in Archives of orthopaedic and trauma surgery
Verified
Journal Article
Open access
PDF file
Massimo InnocentiMassimo Innocenti
Massimo Innocenti
KSKatrijn Smulders
Katrijn Smulders
MAMattia Andreotti
Mattia Andreotti
JWJore H. Willems
Jore H. Willems
GHGijs G. Van Hellemondt
Gijs G. Van Hellemondt
MNMarc W. Nijhof
Marc W. Nijhof
Introduction: Low-grade femoral defects in revision total hip arthroplasty (rTHA) might be preferably treated with a primary implant. Almost no previous study reported the use of standard-length conical tapered (SLCT) stems in these cases. We analyzed a series of cases using a SLCT stem in rTHA with Paprosky type I–II femoral defects. The purpose of the study was to determine clinical and radiographic outcomes in this series of rTHA. Materials and methods: We prospectively followed 87 patients undergoing a femoral component rTHA: 53 Paprosky type I and 34 type II femoral defects. Patient-reported measures (Oxford Hip Score, EQ-5D, VAS pain during rest and activity) were administered at baseline, 1 and 2 years post-operatively. Radiographic subsidence overtime was scored. Kaplan–Meier curves were used to evaluate the subsidence over time, the complication-free survival, and the implant survivorship with reoperation and stem revision as endpoints. Results: The mean follow-up was 72.5 (SD ± 23.9) months. All PROMs significatively improved over time. The average subsidence was 2.8 (SD ± 3.2), 3.6 (SD ± 4.4), and 4.0 (SD ± 4.9) mm at 4, 12, and 24 months respectively. 6 stems had subsidence > 10 mm. The survival without complication was 0.85 (95% CI 0.94–0.77), while the implant survival without reoperation was 0.83 (95% CI 0.95–0.72). The overall stem survival rate was 93.7% (95% CI 0.91–0.97) at 2 years. Conclusion: The use of a SLCT stem in rTHA with Paprosky type I–II femoral defects demonstrated good survival with low subsidence rates during the first 2 years after surgery. Surgeons should consider the use of this primary prosthesis as a potential treatment during stem revision in cases with limited femoral bone loss.