Atul Kapoor

Dr. Atul Kapoor


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2022 in Journal of Medical Ultrasound
Verified
Journal Article
Open access
AKAtul Kapoor
Atul Kapoor
BSBholla Singh Sidhu
Bholla Singh Sidhu
JSJasdeep Singh
Jasdeep Singh
NBNavjot Brar
Navjot Brar
PSParamjit Singh
Paramjit Singh
AKAprajita Kapur
Aprajita Kapur
Background: Laparoscopic cholecystectomy (LC) is the treatment of choice for cholelithiasis; however, there are procedural difficulties in determining preoperative detection of a difficult LC. The current methods using clinical and sonographic variables to identify difficult LCs have limitations to identify gallbladder adhesions which form the most common cause. We present a new method of evaluation using acoustic radiation force impulse (ARFI)-based virtual touch imaging (VTI) for the detection and classification of these patients. Methods: Fifty consecutive patients of cholelithiasis were evaluated preoperatively using conventional scoring system (CSS) and by new adhesion detection and staging (ADS) system, and patients were classified into three classes (I–III) with class I being easy, II and III being moderate-to-high difficulty LCs. Peroperative classification was done based on the difficulty level during surgery after visualization of gallbladder adhesions. The sensitivity, specificity, and area under the curves (AUCs) of both systems were compared. Results: Out of 50 patients, 72% and 54% of patients were in class I by CSS and ADS classification, while 28% and 46% were in class II and III, respectively, and were labeled as difficult LC cases; differences being two classifications were statistically significant (P = 0.02). Sensitivity, specificity, negative predictive value, and accuracy for ADS were 91%, 100%, 93.1%, and 96.0%, and for CSS, 60.9%, 100%, 75%, and 82% with AUCs of 1.0 and 0.63, respectively. Conclusion: ARFI-based VTI accurately detects gallbladder adhesions and can determine the difficult cases of LCs preoperatively using ADS classification and shows higher accuracy than CSS classification, which results in lower operative time and risk of complications.

23 November 2023 in Journal of Clinical Ultrasound
Verified
Journal Article
Closed access
AKAtul Kapoor
Atul Kapoor
ASAnil Singh
Anil Singh
AKAprajita Kapur
Aprajita Kapur
GMGoldaa Mahajan
Goldaa Mahajan
SSShalinder Sharma
Shalinder Sharma

10 January 2022 in Indian Journal of Radiology and Imaging
Verified
Journal Article
Open access
PDF file
AKAtul Kapoor
Atul Kapoor
AKAprajita Kapoor
Aprajita Kapoor
GMGoldaa Mahajan
Goldaa Mahajan
Background Evaluation of suspected coronavirus disease-2019 (COVID-19) patient is a diagnostic dilemma as it commonly presents like influenza in early stages. Studies and guidelines have emerged both for and against the use of imaging as a frontline tool to investigate such patients. Reverse transcriptase-polymerase chain reaction (RT-PCR) is suggested as the backbone of diagnosis. We designed and tested a diagnostic algorithm using artificial intelligence (AI) to determine the role of imaging in the evaluation of patients with acute flu-like presentation. Materials and Methods Overall, 3,235 consecutive patients with flu-like presentation were evaluated over a period of 240 days. All patients underwent plain radiographs of chest with computer-aided detection for COVID-19 (CAD4COVID) AI analysis. Based on the threshold scores, they were divided into two groups: group A (score < 50) and group B (score > 50). Group A patients were discharged and put on routine symptomatic treatment and follow-up with RT-PCR, while group B patients underwent high-resolution computed tomography (HRCT) followed by COVID-19 AI analysis and RT-PCR test. These were then triaged into COVID-19 and non-COVID-19 subgroups based on COVID-19 similarity scores by AI, and lung severity scores were also determined. Results Group A had 2,209 (68.3%) patients with CAD4COVID score of 0.85 on AI. RT-PCR was positive in 415 and false-negative in 115 patients while 12 patients died before the test could be done. The sensitivity and specificity of CAD4COVID AI analysis on plain radiographs for detection of any lung abnormality combined with HRCT AI analysis was 97.9% and 99% using the above algorithm. Conclusion Combined use of chest radiographs and plain HRCT with AI-based analysis is useful and an accurate frontline tool to triage patients with acute flu-like symptoms in non-COVID-19 health care facilities. Publication Date: 10 January 2022 (online) © 2022. Indian Radiological Association. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

28 July 2021 in Indian Journal of Radiology and Imaging
Verified
Journal Article
Open access
PDF file
AKAtul Kapoor
Atul Kapoor
GMGoldaa Mahajan
Goldaa Mahajan
AKAprajita Kapoor
Aprajita Kapoor
Introduction Computed tomographic coronary angiographic (CTCA) has evolved into a robust technique to detect significant stenosis; however, there is a discordance in the anatomic and functional significance of stenosis. Therefore, patients with stable coronary artery disease need to be further evaluated before deciding for any revascularization procedure. Material and Methods A total of 100 consecutive patients of suspected stable coronary artery disease who underwent CTCA were evaluated for functional significance of lesions using onsite computed tomography fractional flow reserve (CTFFR) and the results were compared for detection of both significant and hemodynamically significant/severe stenosis on per vessel and per patient basis and differences were statistically analyzed. Impact of these differences were analyzed for the final outcome and management plan. Results CTCA detected 33 patients with severe stenosis, while 54 patients had hemodynamically significant stenosis on CTFFR. The sensitivity and specificity of CTCA for the detection of significant coronary artery stenosis per vessel basis were 97.7 and 93.3%, respectively, with a negative predictive value of 98.0%. For severe coronary artery stenosis, sensitivity, specificity, and negative and positive predictive values were 51.6, 89, 68.8, and 80%, respectively, on per vessel basis with CTCA. On per patient basis, CTCA showed as sensitivity and specificity of 61 and 84%, respectively, with area under curve (AUC) being 0.92 and 0.67 for significant and severe stenosis, respectively. Discussion Onsite CTFFR is a useful tool to calculate functionally significant stenosis and also improves the sensitivity and specificity of CTCA. CTFFR detected 12% more stenotic vessels in the present study on per vessel basis and 21% on per patient basis. Publication Date: 28 July 2021 (online) © 2021. Indian Radiological Association. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/). Thieme Medical and Scientific Publishers Private Ltd. A-12, Second Floor, Sector -2, NOIDA -201301, India

10 January 2022 in Indian Journal of Radiology and Imaging
Verified
Journal Article
Open access
PDF file
AKAtul Kapoor
Atul Kapoor
GMGoldaa Mahajan
Goldaa Mahajan
AKAprajita Kapoor
Aprajita Kapoor
Objective The aim of this study was to evaluate the use of low peak kilovoltage (kVp) low-volume iodinated contrast protocol for performing coronary computed tomography (CT) angiography (CCTA) in patients using retrospective electrocardiogram (ECG) gating. Materials and Methods Hundred prospective patients undergoing CCTA were studied in two groups, A and B, using 70 kilovoltage (kV) and 120 kV protocols with half and standard intravenous volumes of injected iodinated contrast, respectively. All patients had heart rates less than 100 beats/min and body mass index (BMI) less than 31 kg/m2. Both the groups were evaluated for signal-to-noise (S/N) and contrast-to-noise (C/N) ratios along with radiation dose delivered in millisievert (mSv), and for image quality (IQ), on per patient and per segment basis. Results Patients with group A showed statistically reduced radiation dose of 1.86 mSv compared with 6.86 mSv in group B patients. Marked reduction in image noise with statistically improved S/N and C/N ratios in all coronary vessels was seen in group A. S/N ratios in group A were 20.25, 18.68, 19.04, 17.41, and 18.69 for aorta, left main, left anterior descending, right coronary, and left circumflex arteries while they were 13.34, 11.12, 10.96, 9.74, and 8.67 in group B patients. C/N ratios were also higher in all vessels in group A patients, that is, 19.48, 19.48, 19.04, 19.48, and 17.68, compared with group B patients, who had 12.43, 10.03, 9.23, 9.57, and 8.23 ratios (p < 0.0001). No significant difference in IQ per patient and per vessel was seen between both the groups. Discussion Retrospective ECG-gated low-kVp low-volume iodinated contrast protocol provides good diagnostic quality angiograms in patients with BMI up to 31 kg/m2 and with heart rates of less than 100 beats/min with three times reduced radiation dose. The reduced volume of contrast reduces the cost as well as the chance of contrast-induced nephropathy. The authors certify that they have obtained all appropriate patient consent forms. In the consent forms, the patients have given their consent for their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed. Publication Date: 10 January 2022 (online) © 2022. Indian Radiological Association. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

28 July 2025 in International Surgery Journal
Verified
Journal Article
Open access
PDF file
AKAtul Kapoor
Atul Kapoor
AKAprajita Kapur
Aprajita Kapur
BSBholla Singh Sidhu
Bholla Singh Sidhu
JSJasdeep Singh
Jasdeep Singh
Background: Blue breast cancer is a term used to describe breast nodules that appear deceptively soft (blue) on elastography despite their malignant nature-representing a significant diagnostic challenge in breast imaging. Methods: This prospective study evaluates the efficacy of next-generation shear wave elastography (SWE) technology in the characterization of blue breast cancer through a comprehensive analysis of 150 prospective patients with BIRAD 4-5 solid breast nodules on routine sono-mammography on three different standard elastography systems i.e., Canon Aplio i 800, Mindray Resona i 9 and Siemens Sequoia system (next generation elastography). Results: Our analysis reveals that Siemens next gen 2D-SWE algorithm demonstrated a 88.3% overall improvement in blue cancer detection rate (from 10.0% with Aplio to 98.3% with Sequoia, p<0.001) with a 98.3% reduction in false negatives. The Sequoia system achieved 98.3% sensitivity and 94.4% specificity compared to 0% sensitivity with Resona i9 and 10% sensitivity with Aplio i 800. Diagnostic accuracy increased from 58.7% (Aplio i800) and 53.3% (Resona i9) to 96.0% (Sequoia) (p0.98). Conclusions: Next-generation SWE technology significantly improves blue breast cancer evaluation across all breast densities and histological subtypes, with greatest impact in traditionally challenging scenarios. SWE>85 kPa measurement provides the most reliable diagnostic indicator with near-perfect performance (F1=0.992, AUC=0.992). As a complementary tool to B-mode ultrasound, it enhances clinical confidence in breast lesion assessment and may contribute to earlier cancer detection and improved patient outcomes.