Linliang Yin

Dr. Linliang Yin

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2021 in Journal of Clinical Ultrasound
Verified
Journal Article
Closed access
PDF file
CJChunya Ji
Chunya Ji
ZYZhong Yang
Zhong Yang
LYLinliang Yin
Linliang Yin
XDXuedong Deng
Xuedong Deng
QPQi Pan
Qi Pan
XJXiaoli Jiang
Xiaoli Jiang

10 October 2023 in BMC Pregnancy and Childbirth
Verified
Journal Article
Open access
PDF file
CJChunya Ji
Chunya Ji
KLKai Liu
Kai Liu
XYXin Yang
Xin Yang
YCYan Cao
Yan Cao
XCXiaoju Cao
Xiaoju Cao
DNDong Ni
Dong Ni
Background: To study the validity of an artificial intelligence (AI) model for measuring fetal facial profile markers, and to evaluate the clinical value of the AI model for identifying fetal abnormalities during the first trimester. Methods: This retrospective study used two-dimensional mid-sagittal fetal profile images taken during singleton pregnancies at 11–13+ 6 weeks of gestation. We measured the facial profile markers, including inferior facial angle (IFA), maxilla-nasion-mandible (MNM) angle, facial-maxillary angle (FMA), frontal space (FS) distance, and profile line (PL) distance using AI and manual measurements. Semantic segmentation and landmark localization were used to develop an AI model to measure the selected markers and evaluate the diagnostic value for fetal abnormalities. The consistency between AI and manual measurements was compared using intraclass correlation coefficients (ICC). The diagnostic value of facial markers measured using the AI model during fetal abnormality screening was evaluated using receiver operating characteristic (ROC) curves. Results: A total of 2372 normal fetuses and 37 with abnormalities were observed, including 18 with trisomy 21, 7 with trisomy 18, and 12 with CLP. Among them, 1872 normal fetuses were used for AI model training and validation, and the remaining 500 normal fetuses and all fetuses with abnormalities were used for clinical testing. The ICCs (95%CI) of the IFA, MNM angle, FMA, FS distance, and PL distance between the AI and manual measurement for the 500 normal fetuses were 0.812 (0.780–0.840), 0.760 (0.720–0.795), 0.766 (0.727-0.800), 0.807 (0.775–0.836), and 0.798 (0.764–0.828), respectively. IFA clinically significantly identified trisomy 21 and trisomy 18, with areas under the ROC curve (AUC) of 0.686 (95%CI, 0.585–0.788) and 0.729 (95%CI, 0.621–0.837), respectively. FMA effectively predicted trisomy 18, with an AUC of 0.904 (95%CI, 0.842–0.966). MNM angle and FS distance exhibited good predictive value in CLP, with AUCs of 0.738 (95%CI, 0.573–0.902) and 0.677 (95%CI, 0.494–0.859), respectively. Conclusions: The consistency of fetal facial profile marker measurements between the AI and manual measurement was good during the first trimester. The AI model is a convenient and effective tool for the early screen for fetal trisomy 21, trisomy 18, and CLP, which can be generalized to first-trimester scanning (FTS).

6 October 2017 in Journal of Clinical Ultrasound
Verified
Journal Article
Closed access
PDF file
LYLinliang Yin
Linliang Yin
ZYZhong Yang
Zhong Yang
QPQi Pan
Qi Pan
JZJun Zhang
Jun Zhang
XLXiaobing Li
Xiaobing Li
CHChunhong Hu
Chunhong Hu

1 March 2024 in Ultrasound in Obstetrics & Gynecology
Verified
Journal Article
Open access
CZC. Zheng
C. Zheng
CJC. Ji
C. Ji
BWB. Wang
B. Wang
JZJ. Zhang
J. Zhang
QHQ. He
Q. He
LYLinliang Yin
Linliang Yin
Objective: To construct a prediction model for fetal growth restriction (FGR) during the first trimester of pregnancy and evaluate its screening performance.Methods: This was a prospective cohort study of singleton pregnancies that underwent routine ultrasound screening at 11 to 13 + 6 weeks at the Affiliated Suzhou Hospital of Nanjing Medical University between January 2019 and April 2022. Basic clinical information, ultrasound indicators and serum biomarkers of pregnant women were collected. Fetal weight assessment was based on the fetal growth curve for the Southern Chinese population. FGR was diagnosed according to Delphi consensus criteria. Least absolute shrinkage and selection operator (lasso) regression was used to select variables for inclusion in the model. Discrimination, calibration and clinical effectiveness of the model were evaluated in training and validation cohorts.Results: A total of 1188 pregnant women were included, of whom 108 had FGR. Lasso regression identified seven predictive features, including history of maternal hypertension, maternal smoking or passive smoking, gravidity, uterine artery pulsatility index, ductus venosus pulsatility index and multiples of the median values of placental growth factor and soluble fms‐like tyrosine kinase‐1. The nomogram prediction model constructed from these seven variables accurately predicted FGR, and the area under the receiver‐operating‐characteristics curve in the validation cohort was 0.82 (95% CI, 0.74–0.90). The calibration curve and Hosmer–Lemeshow test demonstrated good calibration, and the clinical decision curve and clinical impact curve supported its practical value in a clinical setting.Conclusion: The multi‐index prediction model for FGR has good predictive value during the first trimester. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

24 April 2021 in BMC Pregnancy and Childbirth
Verified
Journal Article
Open access
PDF file
CJChunya Ji
Chunya Ji
XJXiaoli Jiang
Xiaoli Jiang
LYLinliang Yin
Linliang Yin
XDXuedong Deng
Xuedong Deng
ZYZhong Yang
Zhong Yang
QLQing Liang
Qing Liang
Background: To establish reference ranges of fetal facial profile markers and study their correlations with crown-rump length (CRL) during the first trimester (11 ~ 13+ 6weeks’ gestation) in a Chinese population.Methods: Ultrasonographic images of measuring fetal nuchal translucency (NT) were retrospectively selected randomly in normal fetuses whose parents were both Chinese. The facial markers included inferior facial angle (IFA), maxilla-nasion-mandible (MNM) angle, facial maxillary angle (FMA) and profile line (PL) distance. These markers were measured through ViewPoint 6 software by two experienced sonographers.Results: Three hundred and eighty fetuses were selected. The ICCs (95 % CI) of intra-operator 1 reproducibility of IFA, MNM angle, FMA, PL distance were 0.944 (0.886 ~ 0.973), 0.804 (0.629 ~ 0.902), 0.834 (0.68 ~ 0.918) and 0.935 (0.868 ~ 0.969), respectively. The ICCs (95 % CI) of intra-operator 2 reproducibility of IFA, MNM angle, FMA, PL distance were 0.931 (0.857 ~ 0.967), 0.809 (0.637 ~ 0.904), 0.786 (0.600 ~ 0.892) and 0.906 (0.813 ~ 0.954), respectively. The ICCs (95 % CI) of inter-operator reproducibility of IFA, MNM angle, FMA, PL distance were 0.885 (0.663 ~ 0.953), 0.829 (0.672 ~ 0.915), 0.77 (0.511 ~ 0.891) and 0.844 (0.68 ~ 0.925), respectively. The average ± SD of IFA, MNM angle, FMA and PL distance were 80.2°±7.25°, 4.17°±1.19°, 75.36°±5.31°, 2.78 ± 0.54 mm, respectively. IFA and PL distance significantly decreased with CRL, while MNM angle and FMA significantly increased with CRL.Conclusions: It was feasible to measure fetal facial markers during the first trimester. In Chinese population, the reference ranges of IFA, MNM angle, FMA and PL distance were 80.2°±7.25°, 4.17°±1.19°, 75.36°±5.31°, 2.78 ± 0.54 mm, respectively, and the measurements were found to correlate with CRL.

2 October 2022 in BMC Pregnancy and Childbirth
Verified
Journal Article
Open access
PDF file
XZXiaofeng Zhou
Xiaofeng Zhou
CJChunya Ji
Chunya Ji
LSLingling Sun
Lingling Sun
LYLinliang Yin
Linliang Yin
XDXuedong Deng
Xuedong Deng
YWYanqing Wu
Yanqing Wu
Objectives: To study the correlations between facial profile markers and crown-lump length (CRL) in a Chinese population, and to evaluate the clinical value of these markers for abnormal fetuses during the first trimester (11 to 13+6 gestational weeks). Methods: The facial profile markers were as followings: inferior facial angle (IFA), maxilla-nasion-mandible (MNM) angle, facial maxillary angle (FMA), frontal space (FS) distance and profile line (PL) distance. These markers were measured in facial mid-sagittal section through ViewPoint 6 software. The diagnostic value of these markers for abnormal fetuses was assessed by receiver operating characteristic (ROC) curves. Results: According to the first-trimester scanning (FTS) and follow-up, 31 fetuses were enrolled in the abnormal group, including 14 cases of trisomy 21, 7 cases of trisomy 18, 10 cases with cleft lip and palate (CLP), and 1000 normal fetuses were selected. Among the normal fetuses, the IFA, FS distance and PL distance had negative correlations with CRL. The MNM angle and FMA had positive correlations with CRL. The mean IFA values for fetuses with trisomy 21 and trisomy 18 were 74.11° (standard deviation (SD) 7.48) and 69.88° (SD 7.08), respectively, which were significantly smaller than the normal fetuses (p = 0.013; p = 0.003). The mean MNM angle of fetuses with trisomy 18 and CLP were 6.98° (SD 2.61) and 9.41° (SD 2.57), respectively, which were significantly greater than the normal fetuses (p = 0.005; p < 0.001). The mean FMA values of trisomy 18 fetuses were 63.95° (SD 4.77), which was significantly smaller than the normal fetuses (p < 0.001). The mean FS distance of CLP fetuses was -0.22 mm (SD 1.38), which was significantly smaller than the normal fetuses (p < 0.001). The mean PL distance of trisomy 21, trisomy 18 and CLP fetuses were 2.89 mm (SD 0.41), 2.91 mm (SD 0.56) and 2.71 mm (SD 0.37), respectively. The difference with the normal fetuses had no statistical significance (p = 0.56; p = 0.607; p = 0.54). Conclusions: Fetal facial profile markers had excellent correlations with CRL during the first trimester. IFA had certain clinical significance in detecting trisomy 21. FMA, IFA and MNM angle were reliable indicators for screening trisomy 18. The abnormal MNM angle and FS distance could be used as sensitive indicators for CLP. However, PL distance was not the best markers for trisomy 21, trisomy 18 and CLP.