Dynamic crushing characteristics of coals are closely related with energy absorption and release of coals under certain strain rate. Hence, it is necessary to investigate energy dissipation laws of coal crushing under the impact loads with different strain rates. Based on the dynamic and static mechanical tests, crushing energy, total absorption energy, total releasable elastic latent energy, and relations between fractal feature of fragments, mean particle diameter and energy during crushing behaviors of outburst coal and nonoutburst coal were investigated. According to research results, crushing energy, total absorption energy, and releasable elastic latent energy of outburst coal and nonoutburst coal are related with strain rate, and they present exponential growths with the increase of the strain rate. However, the energy dissipation rate (ratio of crushing energy and incident energy) was basically constant at about 10%∼20%, that is, energy dissipation rate is a variable unrelated with strain rate. There is a good logarithmic relationship between the dynamic compressive strength of coals and the absorption energy density and elastic latent energy density, and dynamic comprehensive strength of coals has important impacts on energy absorption. The fractal features of coal fragments were obvious under dynamic impacts. The higher fractal dimension of fragment and the smaller mean particle diameter of experimental fragments bring the greater energy needed.
Fine dust, represented by Fe-based fine particles and emitted from the production process of the iron and steel industry, is the primary factor causing many diseases represented by industrial pneumoconiosis, and ultra-low dust emission has always been a thorny problem to be solved urgently. To explore the magnetic coagulation effect of Fe-based fine particles in the magnetic field when removing them from industrial flue gas by the magnetic field effect in the iron and steel industry, using FLUENT software, magnetic dipole force was added between particles through user defined function (UDF) based on the computational fluid dynamics-discrete phase model (CFD-DPM) method so that the collision process of particles was then equivalent to their mutual trapping process. Next, the effects of particle size, particle volume fraction, external magnetic field strength, and particle magnetic susceptibility on the magnetic coagulation process were comprehensively studied. Meanwhile, the proton balance equation (PBE) was solved using the partition method on the basis of the computational fluid dynamics-population balance model (CFD-PBM) to compare the coagulation removal effect under random and aligned orientations of magnetic dipoles, respectively. The results showed that the magnetic coagulation strength under the random orientation of magnetic dipoles was greater than that under the aligned orientation. When the particle size of Fe-based fine particles increased from 0.5 μm to 1.5 μm, the magnetic coagulation coefficient decreased from 0.5414 to 0.2882, and the difference in the removal efficiency under the two different orientations of magnetic dipoles became smaller. When the particle volume fraction increased from 0.01 to 0.03, the magnetic coagulation coefficient increased from 0.2353 to 0.5061, and the difference in the removal efficiency under two orientations was enlarged. When the applied external magnetic field strength increased from 0.5 T to 1.0 T, the magnetic coagulation coefficient increased from 0.3940 to 0.5288, and the magnetic susceptibility increased from 0.0250 to 0.0500, the coagulation coefficient increased from 0.3940 to 0.5288, and the difference under two orientations basically stayed unchanged.
This study aimed to investigate the influence of cavity width on the attenuation characteristic of gas explosion wave. Attenuation mechanism of gas explosion wave through cavity was obtained by numerical simulation. The gas explosion shock wave energy can be greatly attenuated through the cavity structure in five stages, namely, plane wave, expansion, oblique reflection, Mach reflection, and reflection stack, to ensure that it is eliminated. Cavities with various width sizes, namely, 500 ∗300 ∗200, 500 ∗500 ∗200, and 500 ∗800 ∗200 (length ∗width ∗height, unit: mm), were experimented to further investigate the attenuation characteristics through a self‐established large‐size pipe gas explosion experimental system with 200 mm diameter and 36 m length. Results showed an evident attenuation effect on flame duration light intensity (FDLI) and peak overpressure with increasing cavity width. Compared with 300 mm, the overall FDLI decreased by 83.0%, and the peak overpressure decreased by 71.2% when the cavity width was 800 mm. The fitting curves of the FDLI and peak overpressure attenuation factors to width‐diameter demonstrated that the critical width‐diameter was 2.19 when the FDLI attenuation factor was 1. The FDLI attenuation factor sharply decreased at the width‐diameter ratio range from 1.5 to 2.5 and basically remained steady at 0.17 at the width‐diameter ratio range from 2.7 to 4.0. The peak overpressure attenuation factor gradually decreased with the increase of width‐diameter ratio and changed from 0.93 to 0.28 with width‐diameter ratio from 1.5 to 4.0. The research results can serve as a good reference for the design of gas explosion wave‐absorbing structures.
26 April 2021 in International Journal of Ambient Energy
To investigate the ability of solar energy to meet building heating requirements in hot-summer/cold-winter zones in China, an experiment was performed with solar capillary mat heating systems (SCHS) from 12/28/2014 to 01/04/2015 in Huainan city. Data from a typical day (Jan. 2) were selected to analyse the dynamic thermal performance, indoor thermal environment, and guaranteed heating time, meanwhile, the economic and environmental benefits of SCHSs were assessed. The results show: (1) The SCHS has good thermal performance, as measured by heat collection efficiency and collection energy; (2) Under the average solar radiation of 420 W/m2, the solar collectors daily collection energy is approximately 113.08 MJ, and the capillary mats’ average heating capacity is 50.9 W/m2; (3) The guaranteed heating time of the SCHS can be up to 14 h a day, indoor air temperatures have a uniform distribution, and the acceptable comfort time (−1.0 < PMV < 0.5) reaches 16 h a day; (4) Compared to energy from electricity, natural gas, or fuel oil, the payback period for solar system investment is 6.3, 11.7, and 6.26 years, respectively, and the SCHSs can reduce CO2 emissions of 1615, 360, and 477 kg/year, respectively. The SCHS can produce environmental and economic benefits.