A new porous Co( ii )-MOF I has been prepared. Gas sorption and catalytic experiments show that the guest-free sample I′ shows the high capacity and selectivity to CO 2 over CH 4 and catalytically oxidize benzyl alcohols efficiently into benzaldehydes.
Costume restoration is one of the important ways to study costume history and culture. The purpose of this paper is to show the characteristics of Chinese costumes more than 1000 years ago, through the research on the costume in the famous ancient Chinese painting DaoLian painting, and provide strong technical support for the research of Chinese ancient costume culture. DaoLian painting is the work of Xuan Zhang, a famous painter in Tang dynasty (618–907), China. From the perspective of clothing engineering, we analyzed the characteristics of costume style, color, and pattern and used the virtual fitting technology to realize digital restoration of the costume of 12 characters in the painting. The results show that it is a practical method to study costume from paintings. The colors, patterns, and character gestures in the paintings provide sufficient information for the archaeology and restoration of ancient costumes. The research results of this paper can provide a new idea for costume archaeology and a reference for modern fashion design and materials for the VR Museum of Ancient Costumes.
16 February 2021 in Journal of Solid State Chemistry
In this article, nitrogen-doped carbon dots (N-CDs) were prepared by a hydrothermal method using microcrystalline cellulose as the carbon source and polyethylenimine as the nitrogen source. The ratio of microcrystalline cellulose to polyethylenimine added exerted a great influence on the fluorescence quantum yield of N-CDs. The fluorescence intensity of N-CDs 2 was significantly affected by the solvent type and pH value, but not influenced by the time of irradiation with the UV lamp. Intriguingly, N-CDs 2 could be applied to temperature sensing (30~70 °C). With the addition of Fe3+ (20 ppm), the fluorescence of N-CDs 2 was greatly quenched, and the quenching rate reached 82.84%. The fluorescence intensity of N-CDs 2 showed a good linear relationship (R2 = 0.995) with Fe3+ concentrations (0~14 ppm), and they achieved a limit of detection of 0.21 ppm. In addition, N-CDs 2 could also effectively detect Fe3+ in real water samples, showing a good recovery rate (98.25%~102.75%) and low relative standard deviation (less than 3%). According to the fluorescence lifetime data, the fluorescence quenching of N-CDs by Fe3+ might be a static process.