Unified power quality conditioner is chiefly employed to offer power quality improvement, especially in grid connected mode of operation in microgrid applications. This article proposes an artificial ecosystem optimized neural network for control of photovoltaic system and battery powered UPQC for microgrid applications. The intelligent routine implemented by the proposed controller helps tune parameters such as the error between load voltage references and measured load voltage signals so that the optimal performance of the system can be reached as its exploratory and exploitation capabilities are leveraged in controller design. A prototype of a three-phase system with a dually powered conditioner is tested and validated in MATLAB-Simulink environment in a variety of dynamic scenarios that are commonly present in a contemporary distribution network, such as grid voltage changes, grid inaccessibility, variation in photovoltaic power output, and nonlinear load. It is shown that the proposed controller, being aware of the instantaneous values of grid voltages, was able to adequately compensate in magnitude and phase under all dynamic scenarios to maintain the load voltage constant at the nominal value and sinusoidal. When the system switches automatically from grid-connected mode to islanded mode due to a grid fault, it was observed that the controller prioritizes delivering uninterrupted power to critical loads and enables fast discharge from the battery. The total harmonic distortion percentages of grid currents and load voltages are found to be within the limits as per IEEE-519 standards.
This paper briefly describes street lighting design and the standard requirements of lighting design in particular reference to UAE. The photometric parameters for different types of roads in Abu Dhabi is analysed and simulated using DIALux. The results are in agreement with the standard requirements. A realtime scenario has been done using cross section developer tool for different streets in Abu Dhabi. Simulation results have been compared with CIE and IESNA standards. In the analysis phase, photometric behaviours including chromaticity coordinates, S/P ratio, CRI, CCT values of different luminaires were compared. Higher CCT accounts for increased alertness in sleep. The proposed methodology shall motivate lighting design aspirants to balance efficient design along with sustainability.
The challenges of ensuring the security of electricity supply (SoES) in large aluminium smelters—particularly those that are self-supplied—provide a compelling rationale for further investigation, as research on this class of industrial systems is limited. Firstly, this paper presents an expert technical perspective on the distinct characteristics and operational challenges associated with aluminium potline loads and their supply systems in self-supplied aluminium smelters. This study then examines the supply infrastructure at Emirates Global Aluminium’s plant in Dubai, which has an installed power generation capacity of 3000 MW, supplying a 2000 MW load on a continuous basis through a network of three 132 kV substations. This high-voltage network is modelled and simulated using the CYME network analysis software module. We consider the following key approaches to ensure stable system voltage for desirable SoES: steady-state voltage control, outage planning and reactive power reserve management, active power flow management and load participation. We then study the influence each of these has on the system voltage and, hence, on the overall SoES of the smelter, using time-domain voltage and frequency curves at key network nodes and active power flow through important network interconnectors. The simulation results clearly demonstrate a significant improvement in the base case event by positively damping the oscillations in these responses, highlighting the significance of maintaining a healthy system voltage within a limit of ±2% of the nominal voltage to ensure SoES of the smelter.