Yue Li

Dr. Yue Li


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Yanghong XiaYanghong Xia
Yanghong Xia
YPYonggang Peng
Yonggang Peng
PYpengcheng yang
pengcheng yang
YLYue Li
Yue Li
WWWei Wei
Wei Wei
Recently, the stability issues when renewable energy sources are connected to the weak grid have obtained great attention. The popular view thinks that the grid impedance is adverse to the system stability. However, in this paper, it is first found that for the photovoltaic (PV) generator, the grid impedance has different influence on the system stability depending on the frequency range when the complete model of the PV generator is taken into consideration. That is, the increase of grid impedance can suppress the low-frequency (<;50 Hz) oscillation, whereas the increase of grid impedance degrades the high-frequency (>300 Hz) stability. Concretely, for the low-frequency range mainly dominated by the power loop and voltage loop of the PV generator, the describing function method is adopted to overcome discontinuity and nonlinearity of the power loop. Then, the low-frequency dynamics such as power oscillation can be analyzed accurately. For the high-frequency range mainly dominated by the phase-locked loop and current loop of the PV generator, the impedance analysis method is adopted to reveal the high-frequency instability mechanism. Through these analyses, the different influence of grid impedance on the low- and high-frequency stability of PV generators can be clearly distinguished. All the conclusions are verified through the real-time hardware-in-loop tests.

1 November 2021 in Sustainable Cities and Society
Verified
Journal Article
Closed access
YLYue Li
Yue Li
Zheming TongZheming Tong
Zheming Tong

23 November 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Yanghong XiaYanghong Xia
Yanghong Xia
YLYue Li
Yue Li
YPYonggang Peng
Yonggang Peng
Miao YuMiao Yu
Miao Yu
WWWei Wei
Wei Wei
In dc distribution networks, the parallel H-bridge dc/dc converters are widely adopted to convert voltage levels with the higher power rating and reliability, in which the parallel HBDCs are naturally connected in input-parallel output-parallel (IPOP) form. However among IPOP HBDCs, there are complicated circulating currents which will influence the safe and steady operation of dc distribution networks. This paper focuses on the suppression of these circulating currents. First, the detailed mathematic model of circulating currents among IPOP HBDCs are derived. Through the model, it is found that various types of circulating currents exist in the system. Hence, the suppression of circulating currents among IPOP HBDCs is a multi-objective control problem. Second, a novel two degrees of freedom control method is proposed to suppress all kinds of circulating currents based on the improved modulation way of HBDCs, which consists of two parts. The droop based control is used to suppress the circulating currents among the multiple HBDCs, while the common mode control is used to control the circulating currents within the single HBDC. All the theoretical analyses are verified by the real-time hardware-in-loop tests

3 August 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
YLYue Li
Yue Li
Yanghong XiaYanghong Xia
Yanghong Xia
NYNi yini
Ni yini
YPYonggang Peng
Yonggang Peng
QFQifan Feng
Qifan Feng
With the increasing integration of renewable energy into the power grid, there is a growing demand for converters that not only provide stable power, but also support auxiliary functions such as grid-voltage regulation. Consequently, grid-forming strategies have attracted significant attention. However, due to the complexities of analyzing nonlinear coupling systems, a comprehensive transient stability analysis of grid-forming converters is still being explored. Conventional analysis methods rely on a simplified quasi-steady-state model for grid-forming voltage source converters (VSCs) and focus on analyzing the transient instability phenomenon caused by the outer power loop. However, this oversimplified model may yield incorrect conclusions. To address this limitation, this paper develops a full-order model that includes quadratic nonlinear terms to accurately represent the system’s nonlinear characteristics. The developed model is then decoupled into multiple low-order modes using a nonlinear decoupling method. These low-order modes can be analyzed using the mature inversing trajectory method, indirectly reflecting the transient stability of grid-forming VSCs under large disturbances. Through varying the inner and outer parameters, the transient stability of grid-forming VSCs is analyzed in detail. Furthermore, the analysis results are verified through hardware-in-loop (HIL) experiments.

25 October 2023 in Energies
Verified
Journal Article
Open access
PDF file
YLYue Li
Yue Li
Yanghong XiaYanghong Xia
Yanghong Xia
JMJunchao Ma
Junchao Ma
YPYonggang Peng
Yonggang Peng
Because of the control complexity of voltage source converters (VSCs), transient stability analysis of multi-VSC parallel systems is challenging, and there are still no effective methods to solve this problem. Inspired by the decoupling principle and combined with the normal form method, an innovative coupling-factor-based nonlinear decoupling (CFND) method is proposed. According to the coupling factors that can be used to evaluate the nonlinear coupling degree among different state variables, the CFND method approximately transforms a high-order nonlinear multi-VSC parallel system into multiple decoupled low-order modes. Thus, the transient stability of the original high-order multi-VSC system can be reflected indirectly by the mature inversing trajectory method and the phase plane method. The CFND method has universality, flexibility, and insensitivity to system order, and no need to construct corresponding Lyapunov functions for different nonlinear systems, breaking through the inherent limitations of traditional analysis methods. Furthermore, this paper derives a reduced-order large-signal model and the corresponding truncated model for a single VSC grid-connected system. The effectiveness of the reduced-order model is verified through simulation waveforms and ROAs partitioning. Subsequently, a generalized model of the multi-VSC grid-connected system is developed. Finally, taking the grid-connected system with three VSCs as an example, the proposed CFND method is used to analyze typical operation cases, and the conclusions of transient stability analysis are verified using the hardware-in-loop (HIL) experiments.