Marco Stampanoni

Marco Stampanoni


Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 July 2010 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
PZPeiping Zhu
Peiping Zhu
KZKai Zhang
Kai Zhang
ZWZhili Wang
Zhili Wang
YLYijin Liu
Yijin Liu
XLXiaosong Liu
Xiaosong Liu
MSMarco Stampanoni
Marco Stampanoni
Phase sensitive X-ray imaging methods can provide substantially increased contrast over conventional absorption-based imaging and therefore new and otherwise inaccessible information. The use of gratings as optical elements in hard X-ray phase imaging overcomes some of the problems that have impaired the wider use of phase contrast in X-ray radiography and tomography. So far, to separate the phase information from other contributions detected with a grating interferometer, a phase-stepping approach has been considered, which implies the acquisition of multiple radiographic projections. Here we present an innovative, highly sensitive X-ray tomographic phase-contrast imaging approach based on grating interferometry, which extracts the phase-contrast signal without the need of phase stepping. Compared to the existing phase-stepping approach, the main advantages of this new method dubbed “reverse projection” are not only the significantly reduced delivered dose, without the degradation of the image quality, but also the much higher efficiency. The new technique sets the prerequisites for future fast and low-dose phase-contrast imaging methods, fundamental for imaging biological specimens and in vivo studies.

23 September 2021 in Advanced Materials
Verified
Journal Article
Open access
PDF file
Francisco Garcia-MorenoFrancisco Garcia-Moreno
Francisco Garcia-Moreno
PKPaul Hans Kamm
Paul Hans Kamm
TNTillmann R. Neu
Tillmann R. Neu
FBFelix Bülk
Felix Bülk
MNMike Andreas Noack
Mike Andreas Noack
JBJohn Banhart
John Banhart
The structure and constitution of opaque materials can be studied with X‐ray imaging methods such as 3D tomography. To observe the dynamic evolution of their structure and the distribution of constituents, for example, during processing, heating, mechanical loading, etc., 3D imaging has to be fast enough. In this paper, the recent developments of time‐resolved X‐ray tomography that have led to what one now calls “tomoscopy” are briefly reviewed A novel setup is presented and applied that pushes temporal resolution down to just 1 ms, that is, 1000 tomograms per second (tps) are acquired, while maintaining spatial resolutions of micrometers and running experiments for minutes without interruption. Applications recorded at different acquisition rates ranging from 50 to 1000 tps are presented. The authors observe and quantify the immiscible hypermonotectic reaction of AlBi10 (in wt%) alloy and dendrite evolution in AlGe10 (in wt%) casting alloy during fast solidification. The combustion process and the evolution of the constituents are analyzed in a burning sparkler. Finally, the authors follow the structure and density of two metal foams over a long period of time and derive details of bubble formation and bubble ageing including quantitative analyses of bubble parameters with millisecond temporal resolution.

2 June 2009 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
SMSamuel Alan McDonald
Samuel Alan McDonald
FMFederica Marone
Federica Marone
CHChristoph Hintermüller
Christoph Hintermüller
GMGordan Mikuljan
Gordan Mikuljan
CDChristian David
Christian David
MSMarco Stampanoni
Marco Stampanoni

3 January 2017 in Advanced Structural and Chemical Imaging
Verified
Journal Article
Open access
PDF file
FMFederica Marone
Federica Marone
ASAlain Studer
Alain Studer
HBHeiner Billich
Heiner Billich
LSLeonardo Sala
Leonardo Sala
MSMarco Stampanoni
Marco Stampanoni
Sub-second full-field tomographic microscopy at third-generation synchrotron sources is a reality, opening up new possibilities for the study of dynamic systems in different fields. Sustained elevated data rates of multiple GB/s in tomographic experiments will become even more common at diffraction-limited storage rings, coming in operation soon. The computational tools necessary for the post-processing of raw tomographic projections have generally not experienced the same efficiency increase as the experimental facilities, hindering optimal exploitation of this new potential. We present here a fast, flexible, and user-friendly post-processing pipeline overcoming this efficiency mismatch and delivering reconstructed tomographic datasets just few seconds after the data have been acquired, enabling fast parameter and image quality evaluation as well as efficient post-processing of TBs of tomographic data. With this new tool, also able to accept a stream of data directly from a detector, few selected tomographic slices are available in less than half a second, providing advanced previewing capabilities paving the way to new concepts for on-the-fly control of dynamic experiments.

17 February 2020 in Nanoscale Horizons
Verified
Journal Article
Open access
PDF file
Lucia RomanoLucia Romano
Lucia Romano
MKMatias Kagias
Matias Kagias
JVJoan Vila-Comamala
Joan Vila-Comamala
KJKonstantins Jefimovs
Konstantins Jefimovs
LTLi-Ting Tseng
Li-Ting Tseng
MSMarco Stampanoni
Marco Stampanoni
Gas-MacEtch of Si with a Pt catalyst allows vertical etching nanostructures with an extreme aspect ratio up to 10 000 : 1.

3 March 2016 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
MKMatias Kagias
Matias Kagias
ZWZhentian Wang
Zhentian Wang
PVPablo Villanueva-Perez
Pablo Villanueva-Perez
KJKonstantins Jefimovs
Konstantins Jefimovs
MSMarco Stampanoni
Marco Stampanoni
X-ray scattering imaging can provide complementary information to conventional absorption based radiographic imaging about the unresolved microstructures of a sample. The scattering signal can be accessed with various methods based on coherent illumination, which span from self-imaging to speckle scanning. The directional sensitivity of the existing real space imaging methods is limited to a few directions on the imaging plane and requires scanning of the optical components, or the rotation of either the sample or the imaging setup, in order to cover the full range of possible scattering directions. In this Letter the authors propose a new method that allows the simultaneous acquisition of scattering images in all possible directions in a single shot. This is achieved by a specialized phase grating and a detector with sufficient spatial resolution to record the generated interference fringe. The structural length scale sensitivity of the system can be tuned by varying its geometry for a fixed grating design. Taking into account ongoing developments in the field of compact x-ray sources that allow high brightness and sufficient spatial coherence, the applicability of omnidirectional scattering imaging in industrial and medical settings is boosted significantly.