Kamaranga Peiris

Dr. Kamaranga Peiris

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2011 in Malaria Journal
Verified
Journal Article
Open access
PDF file
MSMaggy T Sikulu-Lord
Maggy T Sikulu-Lord
KDKayla M Dowell
Kayla M Dowell
LHLeon E. Hugo
Leon E. Hugo
RWRobert A Wirtz
Robert A Wirtz
KMKristin Michel
Kristin Michel
FDFloyd E Dowell
Floyd E Dowell
Background: Mosquito age and species identification is a crucial determinant of the efficacy of vector control programmes. Near-infrared spectroscopy (NIRS) has previously been applied successfully to rapidly, non-destructively, and simultaneously determine the age and species of freshly anesthetized African malaria vectors from the Anopheles gambiae s.l. species complex: An. gambiae s. s. and Anopheles arabiensis. However, this has only been achieved on freshly-collected specimens and future applications will require samples to be preserved between field collections and scanning by NIRS. In this study, a sample preservation method (RNAlater ®) was evaluated for mosquito age and species identification by NIRS against scans of fresh samples. Methods: Two strains of An. gambiae s.s. (CDC and G3) and two strains of An. arabiensis (Dongola, KGB) were reared in the laboratory while the third strain of An. arabiensis (Ifakara) was reared in a semi-field system. All mosquitoes were scanned when fresh and rescanned after preservation in RNAlater ® for several weeks. Age and species identification was determined using a cross-validation. Results: The mean accuracy obtained for predicting the age of young (<7 days) or old (≥ 7 days) of all fresh (n = 633) and all preserved (n = 691) mosquito samples using the cross-validation technique was 83% and 90%, respectively. For species identification, accuracies were 82% for fresh against 80% for RNAlater ® preserved. For both analyses, preserving mosquitoes in RNAlater ® was associated with a highly significant reduction in the likelihood of a misclassification of mosquitoes as young or old using NIRS. Important to note is that the costs for preserving mosquito specimens with RNAlater ® ranges from 3-13 cents per insect depending on the size of the tube used and the number of specimens pooled in one tube. Conclusion: RNAlater ® can be used to preserve mosquitoes for subsequent scanning and analysis by NIRS to determine their age and species with minimal costs and with accuracy similar to that achieved from fresh insects. Cold storage availability allows samples to be stored longer than a week after field collection. Further study to develop robust calibrations applicable to other strains from diverse ecological settings is recommended.

29 October 2021 in Processes
Verified
Journal Article
Open access
PDF file
KPKamaranga Peiris
Kamaranga Peiris
Shawn/Xiaorong WuShawn/Xiaorong Wu
Shawn/Xiaorong Wu
SBScott R. Bean
Scott R. Bean
MPMayra Perez-Fajardo
Mayra Perez-Fajardo
CHChad Matthew Hayes
Chad Matthew Hayes
BBBrent Bean
Brent Bean
Starch, mainly composed of amylose and amylopectin, is the major nutrient in grain sorghum. Amylose and amylopectin composition affects the starch properties of sorghum flour which in turn determine the suitability of sorghum grains for various end uses. Partial least squares regression models on near infrared (NIR) spectra were developed to estimate starch and amylose contents in intact grain sorghum samples. Sorghum starch calibration model with a coefficient of determination (R2) = 0.87, root mean square error of cross validation (RMSECV) = 1.57% and slope = 0.89 predicted the starch content of validation set with R2 = 0.76, root mean square error of prediction (RMSEP) = 2.13%, slope = 0.93 and bias = 0.20%. Amylose calibration model with R2 = 0.84, RMSECV = 2.96% and slope = 0.86 predicted the amylose content in validation samples with R2 = 0.76, RMSEP = 2.60%, slope = 0.98 and bias = −0.44%. Final starch and amylose cross validated calibration models were constructed combining respective calibration and validation sets and used to predict starch and amylose contents in 1337 grain samples from two diverse sorghum populations. Protein and moisture contents of the samples were determined using previously tested NIR spectroscopy models. The distribution of starch and protein contents in the samples of low amylose (15%) and the overall relationship between starch and protein contents of the sorghum populations were investigated. Percent starch and protein were negatively correlated, low amylose lines tended to have lower starch and higher protein contents than lines with high amylose. The results showed that NIR spectroscopy of whole grain can be used as a high throughput pre-screening method to identify sorghum germplasm with specific starch quality traits to develop hybrids for various end uses.

6 May 2019 in Cereal Chemistry
Verified
Journal Article
Closed access
PDF file
KPKamaranga Peiris
Kamaranga Peiris
SBScott R. Bean
Scott R. Bean
ACAnuj Chiluwal
Anuj Chiluwal
RPRamasamy Perumal
Ramasamy Perumal
SJS. V. Krishna Jagadish
S. V. Krishna Jagadish

9 August 2020 in Journal of the Science of Food and Agriculture
Verified
Journal Article
Closed access
PDF file
PAPervin Arı Akın
Pervin Arı Akın
BSBanu Sezer
Banu Sezer
SBScott R. Bean
Scott R. Bean
KPKamaranga Peiris
Kamaranga Peiris
MTMichael Tilley
Michael Tilley
İBİsmail Hakkı Boyacı
İsmail Hakkı Boyacı

18 August 2023 in Foods
Verified
Journal Article
Open access
PDF file
KPKamaranga Peiris
Kamaranga Peiris
SBScott R. Bean
Scott R. Bean
Shawn/Xiaorong WuShawn/Xiaorong Wu
Shawn/Xiaorong Wu
SSSarah Sexton-Bowser
Sarah Sexton-Bowser
TTTesfaye Tesso
Tesfaye Tesso
Near infrared (NIR) spectroscopy is widely used for evaluating quality traits of cereal grains. For evaluating protein content of intact sorghum grains, parallel NIR calibrations were developed using an established benchtop instrumentation (Perten DA-7250) as a baseline to test the efficacy of an adaptive handheld instrument (VIAVI MicroNIR OnSite-W). Spectra were collected from 59 grain samples using both instruments at the same time. Cross-validated calibration models were validated with 33 test samples. The selected calibration model for DA-7250 with a coefficient of determination (R2) = 0.98 and a root mean square error of cross validation (RMSECV) = 0.41% predicted the protein content of a test set with R2 = 0.94, root mean square error of prediction (RMSEP) = 0.52% with a ratio of performance to deviation (RPD) of 4.13. The selected model for the MicroNIR with R2 = 0.95 and RMSECV = 0.62% predicted the protein content of the test set with R2 = 0.87, RMSEP = 0.76% with an RPD of 2.74. In comparison, the performance of the DA-7250 was better than the MicroNIR, however, the performance of the MicroNIR was also acceptable for screening intact sorghum grain protein levels. Therefore, the MicroNIR instrument may be used as a potential tool for screening sorghum samples where benchtop instruments are not appropriate such as for screening samples in the field or as a less expensive option compared with benchtop instruments.

10 May 2023 in Agronomy
Verified
Journal Article
Open access
PDF file
Hugo E. CuevasHugo E. Cuevas
Hugo E. Cuevas
KPKamaranga Peiris
Kamaranga Peiris
SBScott R. Bean
Scott R. Bean
The development of higher nutritional sorghum varieties requires the identification of high protein content germplasm that expands the genetic diversity of breeding programs. Therefore, a near-infrared (NIR) spectroscopy method was developed to predict the protein concentration of whole-grain sorghum with R2 = 0.83, root-mean-square error of prediction = 1.44%, and bias = 0.16%. We evaluated 228 tropical accessions from West and Central Africa maintained by the National Plant Germplasm System (NPGS) of the United States for protein content for three years. The analysis found that the protein concentrations among accessions varied from 5.05 to 15.00% with an average of 10.24%. Correlation analysis between years revealed changes in protein content and ranking across years for multiple accessions. However, heritability of protein concentration was moderately high (H2 = 0.81) indicating most of the observed variation could be determined by genetic differences among accessions. Sixteen tropical accessions with the highest protein concentration (>12.84%) may be used in breeding programs for the development of new and improved nutritional varieties. This assessment documented the range of natural variation for protein content in the NPGS sorghum tropical germplasm collection that could be used to enhance breeding programs focused on biofortification.