Damage cases show that during earthquakes, the sharp stiffness mutation of subway station-tunnel junction structures can lead to dislocations at the connections. To address this, shaking table tests were conducted followed by numerical simulations of a typical junction structure with rigid connections. The modeling method was verified based on the test results. Furthermore, numerical models of junction structures with rigid and flexible connections, single stations, and single tunnels were built, and deformation modes and stress distributions were comparatively analyzed. Combining the experimental and numerical results, it is found that there exists an intensive deformation inconsistency between the stations and the tunnels responsible for the junction structures’ dislocation failures. The station operates in both racking and distortion deformation modes when the tunnel undergoes ovaling deformation. The tunnel bends relative to the end wall at the connection. The junction structure with rigid connections is most at risk at the point located at the tunnel section connected to the end wall and near the bottom plate-sidewall joint. With flexible connections, the tunnels integrally translate relative to the end wall, and the stress response of the end wall openings can be larger than those with rigid connections.
1 January 2023 in Journal of Renewable and Sustainable Energy
Aiming at the problem that the existing computer vision detection technology is difficult to comprehensively and carefully detect the damage status of large wind turbine blades due to the limitation of the field of view, this paper proposes a refined and multi-scale detection method for large-scale wind turbine blades by combining an image stitching algorithm and a deep learning network. First of all, combining the image stitching algorithm with image weighted fusion, images of large wind turbine blades shot in close range are stitched together, so as to realize the clear restoration of the full size and defects of the blades. On this basis, an improved Unet network VGG16Unet is proposed. Combined with transfer learning, the classification and detection of various defects on wind turbine blades under the condition of small dataset training are realized. Finally, by the aid of the combination of the image stitching algorithm and the semantic segmentation network, the refined damage detection of the overall structure of large wind turbine blades is implemented. The research shows that the mean pixel accuracy and the mean intersection over union of the VGG16Unet model are 95.33% and 85.20%, respectively, which is better than the classical semantic segmentation models, fully convolutional neural network model and Unet model. The combination of the VGG16Unet model and the image stitching algorithm not only realizes the global detection of the entire structure but also ensures the detailed detection of each local area, which makes the detection of large wind turbine blades more comprehensive and refined.
The seismic design of underground or aboveground structures is commonly based on the free-field assumption, which neglects the interaction between underground structures–soil–aboveground structures (USSI). This simplification may lead to unsafe or overly conservative, cost-intensive designs. To address this limitation, a series of shaking table tests were conducted on a coupled USSI system, in which the underground component consisted of a subway station connected to tunnels through structural joints to investigate the “city effect” on-site seismic response, particularly under long-period horizontal seismic excitations. Five test configurations were developed, including combinations of one or two aboveground structures, with or without a subway station. These were compared to a free-field case to evaluate differences in dynamic characteristics, acceleration amplification factors (AMFs), frequency content, and response spectra. The results confirm that boundary effects were negligible in the experimental setup. Notably, long-period seismic inputs had a detrimental impact on the field response when structures were present, with the interaction effects significantly altering surface motion characteristics. The findings demonstrate that the presence of a subway station and/or aboveground structure alters the seismic response of the soil domain, with clear dependence on the input motion characteristics and relative structural positioning. Specifically, structural systems lead to de-amplification under high-frequency excitations, while under long-period inputs, they suppress short-period responses and amplify long-period components. These insights emphasize the need to account for USSI effects in seismic design and retrofitting strategies, particularly in urban environments, to achieve safer and more cost-effective solutions.