Paulo Henrique Costa Santos

Dr. Paulo Henrique Costa Santos

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2020
Verified
Book Chapter
Closed access
PDF file
PSPaulo Henrique Costa Santos
Paulo Henrique Costa Santos
PRPeter Roth
Peter Roth
JFJorge Manuel Fernandes
Jorge Manuel Fernandes
VFViktor Fetter
Viktor Fetter
Valentina VassilenkoValentina Vassilenko
Valentina Vassilenko

2 August 2023 in Metabolites
Verified
Journal Article
Open access
PDF file
PSPaulo Henrique Costa Santos
Paulo Henrique Costa Santos
Pedro Catalão MouraPedro Catalão Moura
Pedro Catalão Moura
Valentina VassilenkoValentina Vassilenko
Valentina Vassilenko
The employment of advanced analytical techniques and instrumentation enables the tracing of volatile organic compounds (VOCs) in vestigial concentrations (ppbv-pptv range) for several emerging applications, such as the research of disease biomarkers in exhaled air, the detection of metabolites in several biological processes, and the detection of pollutants for air quality control. In this scope, the storage of gaseous samples is crucial for preserving the integrity and stability of the collected set of analytes. This study aims to assess the suitability of three commercially available syringes as air containers (AC) that are commonly used for the collection, storage, isolation, and transportation of samples: glass syringes with glass plungers (AC1), and two plastic syringes, one with plastic plungers (AC2), and one with rubbered plungers (AC3). For this purpose, 99 air samples with different times of storage (from 10 min to 24 h) were analyzed using a Gas Chromatography—Ion Mobility Spectrometry device and the degradation of the samples was properly assessed by comparing the changes in the VOCs’ emission profiles. The quality of the method was assured by via the measurement of the blank’s spectra before each experimental run, as well as by the consecutive measurement of the three replicates for each sample. A statistical analysis of the changes in the VOCs’ emission patterns was performed using principal component analysis (PCA). The results, with a total explained variance of 93.61%, indicate that AC3 is the most suitable option for the long-term storage of air samples. Thus, AC3 containers demonstrated a higher capacity to preserve the stability and integrity of the analytes compared to AC1 and AC2. The findings of the short-term effects analysis, up to 1 h, confirm the suitability of all analyzed syringe-based containers for sample-transferring purposes in onsite analysis.

30 June 2021
Verified
Book Chapter
Closed access
PDF file
PSPaulo Henrique Costa Santos
Paulo Henrique Costa Santos
VVValentina Vassilenko
Valentina Vassilenko
CCCarolina Conduto
Carolina Conduto
JFJorge M. Fernandes
Jorge M. Fernandes
Pedro Catalão MouraPedro Catalão Moura
Pedro Catalão Moura
PBPaulo Bonifácio
Paulo Bonifácio

1 December 2021 in Results in Optics
Verified
Journal Article
Open access
Pedro JorgePedro Jorge
Pedro Jorge
ICInês A. Carvalho
Inês A. Carvalho
FMFilipe M. Marques
Filipe M. Marques
VPVanessa Pinto
Vanessa Pinto
PSPaulo Henrique Costa Santos
Paulo Henrique Costa Santos
NSNuno Azevedo Silva
Nuno Azevedo Silva