Yanli Su

Ms. Yanli Su

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2023 in Buildings
Verified
Journal Article
Open access
PDF file
CJChenhua Jin
Chenhua Jin
YSYanli Su
Yanli Su
ZPZuanfeng Pan
Zuanfeng Pan
SMShaoping Meng
Shaoping Meng
Experimental observations on three reinforced concrete shear walls with small shear span-to-depth ratio (SDR) under combined high vertical axial load and horizontal cyclic loads are presented. The influence of high axial load ratio (ALR) on the failure mode, hysteretic behaviour, displacement ductility, shear strength and stiffness of the squat shear walls is investigated. In addition, a novel built-in strain gauges measuring system is employed for measuring the strain conditions in the reinforcements during the whole test process. Test results indicate that high axial load restrains the development of cracks and improves the shear load capacity, but that it also decreases ductility and energy dissipation and aggravates stiffness degradation. Concrete crush and out-of-plane buckling were observed in all specimens, resulting in the final failure of the specimens. According to the strain analysis, the section of the squat walls coincided well with the assumption of plane section under the condition of high ALR. With the increase of ALR, the depth of the compression zone of members increases, while the length of plastic hinge decreases. When the axial load is relatively small, the vertical and horizontal reinforcements provided almost equal contribution to the shear capacity of squat shear walls. However, under extremely high axial load, both vertical and horizontal reinforcements cannot provide full contribution to the shear capacity. The hysteretic behaviours of the tested shear walls were simulated by a cyclic softened membrane model (CSMM). Simulation results indicate that CSMM captured well the nonlinear characteristics of the squat shear wall under high axial load.

1 February 2025 in Journal of Composites for Construction
Verified
Journal Article
Closed access
YSYanli Su
Yanli Su
JSJiaqi Shang
Jiaqi Shang
CJChenhua Jin
Chenhua Jin
Zhang PuZhang Pu
Zhang Pu
SSShamim Ahmed Sheikh
Shamim Ahmed Sheikh
CWChang Wu
Chang Wu

1 November 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Chang WuChang Wu
Chang Wu
YSYanli Su
Yanli Su
CJChenhua Jin
Chenhua Jin
ZPZuanfeng Pan
Zuanfeng Pan
SMShaoping Meng
Shaoping Meng
Engineered cementitious composite (ECC) is a high-performance composite material with greater shear deformation and shear strength than normal concrete, which has been proposed for use as a shear component in structures. This study modeled three frames, a pure reinforced concrete (RC) frame, an RC frame with concrete short columns and an RC frame with ECC short columns, using the incremental dynamic analysis (IDA) method to evaluate the contribution of ECC to the structural performance. A modified IMK model was applied to model the entire history of the mechanical behaviors of the short columns. The IDA curves, interfloor displacement angle distribution and limit state of the vertex displacement of the frames were analyzed to investigate the seismic responses of the frames. The model analysis results showed that an RC frame with short columns would form a weak layer on the floor where the short columns were located, which greatly weakened the seismic performance of the structure. ECC was certified to be effective in improving the shear formation of the short columns in the frames. The frame with ECC short columns improved the seismic performance of the structure to a certain extent relative to the frame with RC short columns. The deformation capacity of the frame with ECC short columns was close to that of the pure RC frame at the collapse level.

22 May 2024 in Advances in Structural Engineering
Verified
Journal Article
Closed access
YSYanli Su
Yanli Su
CWChang Wu
Chang Wu
GWGuolin Wang
Guolin Wang
JSJiaqi Shang
Jiaqi Shang
Zhang PuZhang Pu
Zhang Pu
This paper presents the experimental study on the reinforced concrete (RC) beam strengthened with externally bonded carbon fiber reinforced polymer (EB-CFRP) laminate and engineered cementitious composites (ECC) material. A total of six beams were tested under the four-point bending test to investigate the influence of strengthening scheme, type of CFRP laminate and the width of CFRP plate on the flexural response. The results revealed that hybrid strengthened beam with the technical of EB-CFRP and ECC transition layer significantly enhanced the crack load (29.0%–133.3%), yield load (50.9%–96.5%) and ultimate load (50.0%–81.9%) of the beams relative to the control beam. The employment of ECC material was an ideal transition layer for delaying the interfacial debonding of CFRP laminate, where the ultimate tensile strain of CFRP plate in hybrid strengthened beams was 13.2%–33.33% higher than that of beam merely strengthened with EB-CFRP plate. Beams strengthened with CFRP sheet had the greater flexural performance and higher utilization of CFRP than its counterparts strengthened with CFRP plate. Moreover, the predicted model associated with ultimate bearing capacity of the hybrid beams was provided based on ACI 440.2R-08, which was relatively conservative with a margin for the ultimate load of the hybrid strengthened beams.

19 June 2025 in Advances in Structural Engineering
Verified
Journal Article
Closed access
Chang WuChang Wu
Chang Wu
MXMingwen Xu
Mingwen Xu
YSYanli Su
Yanli Su
XWXinru Wang
Xinru Wang
CJChenhua Jin
Chenhua Jin
Corrosion of steel rebars is a principal factor leading to a reduced load-bearing capacity of structural components, necessitating appropriate repairing. The exceptional tensile properties, toughness, and crack control of Engineered Cementitious Composite (ECC) provide significant advantages in the repair of concrete components with corroded steel rebar. The present study investigates the effectiveness of ECC in repairing the flexural capacity of concrete structures with highly corroded steel rebars. The interfacial bond performance between ECC and concrete was assessed through bond flexural tests, while direct tension tests on reduced cross-sectional steel rebars surrounded by ECC evaluated the recovery of load-bearing capacity and repair effectiveness across different bond lengths. Bending tests on ECC repaired beams were also conducted to further explore their repair efficiency. The experimental findings revealed that a bond length of 5.5D ensures effective load transfer, and consequently the ultimate load recovery rate of corroded steel rebar specimens repaired with ECC exceeds 96%, with some specimens achieving full recovery. Experimental results also demonstrated the efficacy of ECC in repairing concrete structures with corroded steel rebars, achieving notable recovery rates that are nearly equivalent to or exceed 90% in both yield and ultimate strengths. A theoretical analysis was conducted to calculate the load-bearing capacity of ECC repaired specimens, explaining the differences in load-bearing capacities compared to uncorroded concrete beams.

8 August 2025 in Engineering Structures
Verified
Journal Article
Closed access
PZPu Zhang
Pu Zhang
XCXingyu Chang
Xingyu Chang
XTXianghua Tao
Xianghua Tao
YSYanli Su
Yanli Su
ZYZhaoxu Yang
Zhaoxu Yang
SSShamim Ahmed Sheikh
Shamim Ahmed Sheikh