Yaser Maddahi

Dr. Yaser Maddahi

Tactile Robotics Ltd.
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2021 in Robotics
Verified
Journal Article
Open access
PDF file
GGGowri Shankar Giri
Gowri Shankar Giri
YMYaser Maddahi
Yaser Maddahi
Kourosh ZareiniaKourosh Zareinia
Kourosh Zareinia
Recent technological development has led to the invention of different designs of haptic devices, electromechanical devices that mediate communication between the user and the computer and allow users to manipulate objects in a virtual environment while receiving tactile feedback. The main criteria behind providing an interactive interface are to generate kinesthetic feedback and relay information actively from the haptic device. Sensors and feedback control apparatus are of paramount importance in designing and manufacturing a haptic device. In general, haptic technology can be implemented in different applications such as gaming, teleoperation, medical surgeries, augmented reality (AR), and virtual reality (VR) devices. This paper classifies the application of haptic devices based on the construction and functionality in various fields, followed by addressing major limitations related to haptics technology and discussing prospects of this technology.

1 January 2015 in Surgical Neurology International
Verified
Journal Article
Open access
GSGarnetteR Sutherland
GarnetteR Sutherland
YMYaser Maddahi
Yaser Maddahi
Kourosh ZareiniaKourosh Zareinia
Kourosh Zareinia
LGLiuShi Gan
LiuShi Gan
SLSanju Lama
Sanju Lama
The treatment of glioma remains a significant challenge with high recurrence rates, morbidity, and mortality. Merging image guided robotic technology with microsurgery adds a new dimension as they relate to surgical ergonomics, patient safety, precision, and accuracy. An image-guided robot, called neuroArm, has been integrated into the neurosurgical operating room, and used to augment the surgical treatment of glioma in 18 patients. A case study illustrates the specialized technical features of a teleoperated robotic system that could well enhance the performance of surgery. Furthermore, unique positional and force information of the bipolar forceps during surgery were recorded and analyzed. The workspace of the bipolar forceps in this robot-assisted glioma resection was found to be 25 × 50 × 50 mm. Maximum values of the force components were 1.37, 1.84, and 2.01 N along x, y, and z axes, respectively. The maximum total force was 2.45 N. The results indicate that the majority of the applied forces were less than 0.6 N. Robotic surgical systems can potentially increase safety and performance of surgical operation via novel features such as virtual fixtures, augmented force feedback, and haptic high-force warning system. The case study using neuroArm robot to resect a glioma, for the first time, showed the positional information of surgeon's hand movement and tool-tissue interaction forces.

5 November 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GGGautham Giri
Gautham Giri
YMYaser Maddahi
Yaser Maddahi
Kourosh ZareiniaKourosh Zareinia
Kourosh Zareinia
Robotics is a rapidly growing field, and the innovative idea to scale down the size of robots to the nanometer level has paved a new way of treating human health. Nanorobots have become the focus of many researchers aiming to explore their many potential applications in medicine. This paper focuses on manufacturing techniques involved in the fabrication of nanorobots and their associated challenges in terms of design architecture, sensors, actuators, powering, navigation, data transmission, followed by challenges in applications. In addition, an overview of various nanorobotic systems addresses different architectures of a nanorobot. Moreover, multiple medical applications, such as oncology, drug delivery, and surgery, are reviewed and summarized.

5 May 2016 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
Kourosh ZareiniaKourosh Zareinia
Kourosh Zareinia
YMYaser Maddahi
Yaser Maddahi
LGLiu Shi Gan
Liu Shi Gan
AGAhmad Ghasemloonia
Ahmad Ghasemloonia
SLSanju Lama
Sanju Lama
GSGarnette R. Sutherland
Garnette R. Sutherland
The ability to exert an appropriate amount of force on brain tissue during surgery is an important component of instrument handling. It allows surgeons to achieve the surgical objective effectively while maintaining a safe level of force in tool-tissue interaction. At the present time, this knowledge, and hence skill, is acquired through experience and is qualitatively conveyed from an expert surgeon to trainees. These forces can be assessed quantitatively by retrofitting surgical tools with sensors, thus providing a mechanism for improved performance and safety of surgery, and enhanced surgical training. This paper presents the development of a force-sensing bipolar forceps, with installation of a sensory system, that is able to measure and record interaction forces between the forceps tips and brain tissue in real time. This research is an extension of a previous research where a bipolar forceps was instrumented to measure dissection and coagulation forces applied in a single direction. Here, a planar forceps with two sets of strain gauges in two orthogonal directions was developed to enable measuring the forces with a higher accuracy. Implementation of two strain gauges allowed compensation of strain values due to deformations of the forceps in other directions (axial stiffening) and provided more accurate forces during microsurgery. An experienced neurosurgeon performed five neurosurgical tasks using the axial setup and repeated the same tasks using the planar device. The experiments were performed on cadaveric brains. Both setups were shown to be capable of measuring real-time interaction forces. Comparing the two setups, under the same experimental condition, indicated that the peak and mean forces quantified by planar forceps were at least 7% and 10% less than those of axial tool, respectively; therefore, utilizing readings of all strain gauges in planar forceps provides more accurate values of both peak and mean forces than axial forceps. Cross-correlation analysis between the two force signals obtained, one from each cadaveric practice, showed a high similarity between the two force signals.

27 January 2015 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
Kourosh ZareiniaKourosh Zareinia
Kourosh Zareinia
YMYaser Maddahi
Yaser Maddahi
CNCanaan Ng
Canaan Ng
NSNariman Sepehri
Nariman Sepehri
GSGarnette R. Sutherland
Garnette R. Sutherland

1 August 2015 in World Neurosurgery
Verified
Journal Article
Closed access
LGLiu Shi Gan
Liu Shi Gan
Kourosh ZareiniaKourosh Zareinia
Kourosh Zareinia
SLSanju Lama
Sanju Lama
YMYaser Maddahi
Yaser Maddahi
FYFang Wei Yang
Fang Wei Yang
GSGarnette R. Sutherland
Garnette R. Sutherland