Aims: We aimed to investigate the association of clinically overt and silent brain lesions with cognitive function in atrial fibrillation (AF) patients. Methods and results: We enrolled 1227 AF patients in a prospective, multicentre cohort study (Swiss-AF). Patients underwent standardized brain magnetic resonance imaging (MRI) at baseline and after 2 years. We quantified new small non-cortical infarcts (SNCIs) and large non-cortical or cortical infarcts (LNCCIs), white matter lesions (WML), and microbleeds (Mb). Clinically, silent infarcts were defined as new SNCI/LNCCI on follow-up MRI in patients without a clinical stroke or transient ischaemic attack (TIA) during follow-up. Cognition was assessed using validated tests. The mean age was 71 years, 26.1% were females, and 89.9% were anticoagulated. Twenty-eight patients (2.3%) experienced a stroke/TIA during 2 years of follow-up. Of the 68 (5.5%) patients with ≥1 SNCI/LNCCI, 60 (88.2%) were anticoagulated at baseline and 58 (85.3%) had a silent infarct. Patients with brain infarcts had a larger decline in cognition [median (interquartile range)] changes in Cognitive Construct score [−0.12 (−0.22; −0.07)] than patients without new brain infarcts [0.07 (−0.09; 0.25)]. New WML or Mb were not associated with cognitive decline. Conclusion: In a contemporary cohort of AF patients, 5.5% had a new brain infarct on MRI after 2 years. The majority of these infarcts was clinically silent and occurred in anticoagulated patients. Clinically, overt and silent brain infarcts had a similar impact on cognitive decline. Clinical Trial Registration: ClinicalTrials.gov Identifier: NCT02105844, https://clinicaltrials.gov/ct2/show/NCT02105844
Objective: The prognostic value of left atrial (LA) dimensions may differ between patients with and without atrial fibrillation (AF).Methods: MEDLINE and EMBASE were searched for studies that investigated the association between LA echocardiographic parameters measured by transthoracic echocardiography and cardiovascular outcomes in patients with or without AF. Data were independently abstracted by two reviewers and pooled using random-effects meta-analysis. The primary outcome was incident stroke or thromboembolic events. Secondary outcomes were heart failure, all-cause mortality and major adverse cardiac events (MACE).Results: Twenty-three studies of patients with AF (14 939 patients) and 68 studies of patients without AF (50 720 patients) in this systematic review. Increasing LA diameter was significantly associated with stroke and thromboembolic events in patients without AF (risk ratio (RR) 1.38, 95% CI 1.02 to 1.87; p=0.03), but not in patients with AF (RR 1.02, 95% CI 0.98 to 1.07; p=0.27; p for difference=0.05). Increasing LA diameter index was significantly associated with MACE in patients with AF (RR 1.13, 95% CI 1.09 to 1.17; p<0.001) and in patients without AF (RR 2.98, 95% CI 1.90 to 4.66; p<0.001), with stronger effects in non-AF populations (p for difference <0.001). Greater LA volume index was significantly associated with the risk of MACE in patients with AF (RR 1.01, 95% CI 1.00 to 1.02; p=0.03) and in non-AF populations (RR 1.08, 95% CI 1.05 to 1.10; p<0.001), the association being stronger in individuals without AF (p for difference <0.001).Conclusions: Larger LA parameters were associated with various adverse cardiovascular events. Many of these associations were stronger in individuals without AF, highlighting the potential importance of LA myopathy.
Background: Inflammation plays an important role in the initiation and progression of atrial fibrillation (AF), but data about the relationship between subclinical inflammation and recurrence of AF after catheter ablation remains poorly studied. We aimed to assess whether plasma levels of C-reactive protein (CRP) are associated with long-term AF recurrence following catheter ablation. Methods: Prior to the intervention, plasma CRP concentrations were measured in patients who underwent first catheter ablation for AF. AF recurrence was evaluated after 12 months and defined as any AF episode longer than 30 s recorded on either 12-lead electrocardiogram, 24-h Holter or 7-day Holter monitoring. Multivariable adjusted Cox models were constructed to examine the association of CRP levels and AF recurrence. Results: Of the 711 patients (mean age: 61 years, 25% women) included in this study, 247 patients (35%) experienced AF recurrence after ablation. Patients who were in the highest CRP quartile had a higher rate of recurrent AF compared to those who were in the lowest quartile (53.4 vs. 33.1% at 1 year of follow-up; P = 0.004). The adjusted hazard ratios (aHR) of recurrent AF across increasing quartiles of CRP were 1.0 (reference), 1.26 (95% confidence interval [CI], 0.86–1.84), 1.15 (95% CI, 0.78–1.70) and 1.60 (95% CI, 1.10–2.34) (P trend = 0.015). A similar effect was observed when CRP was analyzed as continuous variable (aHR per unit increase, 1.21; 95% CI, 1.05–1.39; P = 0.009). When a predefined CRP cut-off of 3 mg/l was applied, patients with CRP levels of 3 mg/l or above had a higher risk of AF recurrence than those with levels below (aHR, 1.44; 95% CI, 1.06–1.95; P = 0.019). Conclusions: Increasing pre-interventional CRP levels are associated with a higher risk of AF recurrence in patients undergoing catheter ablation for AF. Trail registration: ClinicalTrials.gov identifier, NCT03718364.