Understanding the biochemical relationship between serum and dermal interstitial fluid (dISF) is critical for advancing minimally invasive diagnostics with wearables and point of care devices focusing on most relevant biomarkers accessible in the ISF. This work compares the composition of dISF and serum using Xsensio’s microneedle-based collector, which yields an average of 3.4 L/h. In the first study, total protein content, human serum albumin (HSA), and immunoglobulin G (IgG) are quantified in twelve volunteers. A second study is dedicated to screening 50 inflammation-related protein biomarkers across twenty volunteers. The results demonstrate that dISF closely resembles serum in its major protein constituents but at reduced concentrations (e.g., 57% for total protein). Strong correlations are observed between dISF and serum for CRP and SAA (), primarily driven by a subject with pathological levels, demonstrating the ability of dISF to reflect systemic inflammation. This study originally reports NT-proBNP detection at comparable levels in both fluids, suggesting that dISF could serve as a reliable proxy for blood NT-proBNP in the non-invasive diagnosis of cardiac failure. Cytokine profiling reveals 36 detectable cytokines, including several unique to dISF. Notably, interleukin concentrations are found to be highly similar between the two fluids. These experimental findings support dISF as a promising diagnostic medium for monitoring both localized and systemic biomarkers in clinical applications.
In this paper, we propose a novel approach to utilize silicon nanowires as high-sensitivity pH sensors. Our approach works based on fixing the current bias of silicon nanowires Ion Sensitive Field Effect Transistors (ISFETs) and monitor the resulting drain voltage as the sensing signal. By fine tuning the injected current levels, we can optimize the sensing conditions according to different sensor requirements. This method proves to be highly suitable for real-time and continuous measurements of biomarkers in human biofluids. To validate our approach, we conducted experiments, with real human sera samples to simulate the composition of human interstitial fluid (ISF), using both the conventional top-gate approach and the optimized constant current method. We successfully demonstrated pH sensing within the physiopathological range of 6.5 to 8, achieving an exceptional level of accuracy in this complex matrix. Specifically, we obtained a maximum error as low as 0.92% (equivalent to 0.07 pH unit) using the constant-current method at the optimal current levels (1.71% for top-gate). Moreover, by utilizing different pools of human sera with varying total protein content, we demonstrated that the protein content among patients does not impact the sensors’ performance in pH sensing. Furthermore, we tested real-human ISF samples collected from volunteers. The obtained accuracy in this scenario was also outstanding, with an error as low as 0.015 pH unit using the constant-current method and 0.178 pH unit in traditional top-gate configuration.
In this paper, we propose a novel approach to utilize silicon nanowires as high-sensitivity pH sensors. Our approach works based on fixing the current bias of silicon nanowires Ion Sensitive Field Effect Transistors (ISFETs) and monitor the resulting drain voltage as the sensing signal. By fine tuning the injected current levels, we can optimize the sensing conditions according to different sensor requirements. This method proves to be highly suitable for real-time and continuous measurements of biomarkers in human biofluids. To validate our approach, we conducted experiments, with real human sera samples to simulate the composition of human interstitial fluid (ISF), using both the conventional top-gate approach and the optimized constant current method . We successfully demonstrated pH sensing within the physiopathological range of 6.5 to 8, achieving an exceptional level of accuracy in this complex matrix. Specifically, we obtained a maximum error as low as 0.92\% (equivalent to 0.07 pH unit) using the constant-current method at the optimal current levels (1.71\% for top-gate). Moreover, by utilizing different pools of human sera with varying total protein content, we demonstrated that the protein content among patients does not impact the sensors' performance in pH sensing. Furthermore, we tested real-human ISF samples collected from volunteers. The obtained accuracy in this scenario was also outstanding, with an error as low as 0.015 pH unit using the constant-current method and 0.178 pH unit in traditional top-gate configuration.