Jinsoo Uh

Dr. Jinsoo Uh

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2014 in Medical Physics
Verified
Journal Article
Closed access
JUJinsoo Uh
Jinsoo Uh
TMThomas E. Merchant
Thomas E. Merchant
YLYimei Li
Yimei Li
XLXingyu Li
Xingyu Li
CHChiaho Hua
Chiaho Hua

1 June 2013 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
JUJinsoo Uh
Jinsoo Uh
TMThomas E. Merchant
Thomas E. Merchant
YLYimei Li
Yimei Li
TFTianshu Feng
Tianshu Feng
AGAmar Gajjar
Amar Gajjar
CHChiaho Hua
Chiaho Hua

25 May 2017 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
JUJinsoo Uh
Jinsoo Uh
MKMatthew J. Krasin
Matthew J. Krasin
YLYimei Li
Yimei Li
XLXingyu Li
Xingyu Li
CTChristopher Tinkle
Christopher Tinkle
CHChiaho Hua
Chiaho Hua

1 September 2015 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
JUJinsoo Uh
Jinsoo Uh
TMThomas E. Merchant
Thomas E. Merchant
YLYimei Li
Yimei Li
XLXingyu Li
Xingyu Li
NSNoah D. Sabin
Noah D. Sabin
CHChiaho Hua
Chiaho Hua

18 October 2016 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
JUJinsoo Uh
Jinsoo Uh
MKM Ayaz Khan
M Ayaz Khan
CHChiaho Hua
Chiaho Hua
This study aimed to develop a practical and accurate 4-dimensional (4D) magnetic resonance imaging (MRI) method using a non-navigator, image-based internal respiratory surrogate derived by dimensionality reduction (DR). The use of DR has been previously suggested but not implemented for reconstructing 4D MRI, despite its practical advantages. We compared multiple image-acquisition schemes and refined a retrospective-sorting process to optimally implement a DR-derived surrogate. The comparison included an unconventional scheme that acquires paired slices alternately to mitigate the internal surrogate’s dependency on a specific slice location. We introduced ‘target-oriented sorting’, as opposed to conventional binning, to quantify the coherence in retrospectively sorted images, thereby determining the minimal scan time needed for sufficient coherence. This study focused on evaluating the proposed method using digital phantoms which provided unequivocal gold standard. The evaluation indicated that the DR-based respiratory surrogate is highly accurate: the error in amplitude percentile of the surrogate signal was less than 5% with the optimal scheme. Acquiring alternating paired slices was superior to the conventional scheme of acquiring individual slices; the advantage of the unconventional scheme was more pronounced when a substantial phase shift occurred across slice locations. The analysis of coherence across sorted images confirmed the advantage of higher sampling efficiencies in non-navigator respiratory surrogates. We determined that a scan time of 20 s per imaging slice was sufficient to achieve a mean coherence error of less than 1% for the tested respiratory patterns. The clinical applicability of the proposed 4D MRI has been demonstrated with volunteers and patients. The diaphragm motion in 4D MRI was consistent with that in dynamic 2D imaging which was regarded as the gold standard (difference within 1.8 mm on average).

1 July 2021 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
JUJinsoo Uh
Jinsoo Uh
CWChuang Wang
Chuang Wang
SASahaja Acharya
Sahaja Acharya
MKMatthew J. Krasin
Matthew J. Krasin
CHChia-Ho Hua
Chia-Ho Hua