Belinda Chan

Dr. Belinda Chan

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Advances in Neonatal Care
Verified
Journal Article
Closed access
BCBelinda Chan
Belinda Chan
SGSasha Gordon
Sasha Gordon
MYMichelle Yang
Michelle Yang
JWJennifer Weekes
Jennifer Weekes
LDLogan Dance
Logan Dance
Background: Abdominal x-ray (KUB) routinely aids in detecting necrotizing enterocolitis (NEC), one of the most serious neonatal intestinal diseases. However, a KUB may miss up to 50% of the early signs of NEC. Recent advances in abdominal ultrasound (AUS) can expedite this diagnosis and improve clinical management. Purposes: To illustrate AUS findings that suggest NEC through 3 case examples. To review current literature regarding advantages and limitations of AUS compared with KUB. Results: The added visualization of intra-abdominal structures with AUS compared with KUB improves the diagnosis and management of NEC. Some AUS features are highly suggestive of impending bowel perforation, while others can confirm bowel perforation despite a negative radiograph. Implications for Practice: AUS expedites time to diagnosis of NEC and helps to stratify patients who may fail medical management and require surgical intervention. Implications for research: More quality improvement studies are needed to validate an AUS protocol for the management of NEC. Advances in technology, such as contrast-enhanced ultrasound, may improve NEC detection with AUS in the future. Video Abstract available at https://journals.lww.com/advancesinneonatalcare/Pages/videogallery.aspx.

Verified
Journal Article
Open access
PDF file
Yogen SinghYogen Singh
Yogen Singh
BCBelinda Chan
Belinda Chan
SNShahab Noori
Shahab Noori
Rangasamy RamanathanRangasamy Ramanathan
Rangasamy Ramanathan
Persistent Patent Ductus Arteriosus (PDA) is prevalent among extremely preterm infants, with its occurrence inversely related to gestational age. A persistent PDA correlates with increased mortality and morbidities such as intraventricular hemorrhage, pulmonary hemorrhage, chronic lung disease, bronchopulmonary dysplasia, and necrotizing enterocolitis as observed clinically. Conversely, numerous randomized controlled trials have failed to demonstrate significant benefits from PDA treatment. One contributing factor to these conflicting findings is that PDA affects each individual differently depending on the cardiovascular decompensation and its hemodynamic impact. PDA management should be based on the hemodynamic significance, rather than just the presence or size of PDA. This comprehensive narrative review paper describes echocardiographic parameters that allow a better understanding of the hemodynamic impact of PDA. A newer modality, like lung ultrasound, is also described here as an adjunct to assess the PDA impact on the lungs from pulmonary overcirculation.

23 February 2021 in Nutrition in Clinical Practice
Verified
Journal Article
Closed access
PDF file
CBCharity Bushati
Charity Bushati
BCBelinda Chan
Belinda Chan
AOAlisha Harmeson Owen
Alisha Harmeson Owen
AWAnne Woodbury
Anne Woodbury
MYMichelle Yang
Michelle Yang
MBMariana Baserga
Mariana Baserga

18 April 2023 in American Journal of Perinatology
Verified
Journal Article
Closed access
PDF file
MTMicaela Thomas
Micaela Thomas
HDHeather Day
Heather Day
BPBrandy Petersen
Brandy Petersen
TMTrisha Marchant
Trisha Marchant
CJCory Jones
Cory Jones
BCBelinda Chan
Belinda Chan
Objective Monitoring heart rate (HR) and oxygen saturation (SpO2) in infants is essential in the neonatal intensive care unit. Wireless pulse oximeter technology has been advancing but with limited accuracy data on preterm infants. This observational study compared HR and SpO2 of the wireless Owlet Smart Sock 3 (OSS3) to the wired Masimo SET (Masimo) pulse oximeter in preterm or <2.5 kg infants. Study Design Twenty-eight eligible infants were enrolled. They weighed between 1.7 and 2.5 kg and were without anomalies or medical instability. OSS3 and Masimo simultaneously monitored HR and SpO2 for 60 minutes. The data were aligned by time epoch and filtered for poor tracings. The agreement was compared using the Pearson's correlation coefficient, the Bland–Altman method, average root mean square (ARMS), and prevalence and bias adjusted kappa (PABAK) analyses. Results Two infants' data were excluded due to motion artifacts or device failures. The corrected gestational age and current weights were 35 ± 3 weeks and 2.0 ± 0.2 kg (mean ± standard deviation), respectively. Over 21 hours of data showed that HR was strongly correlated between the two devices (r = 0.98, p < 0.001), with a difference of −1.3 beats per minute (bpm) and the limit of agreement (LOA) −6.3 to 3.4 bpm based on the Bland–Altman method. SpO2 was positively correlated between the two devices (r = 0.71, p < 0.001) with a SpO2 bias of 0.3% (LOA: −4.6 to 4.5%). The estimated ARMS of OSS3 compared with Masimo was 2.3% for SpO2 in the 70 to 100% range. The precision decreased with lower SpO2. A strong agreement (PABAK = 0.94) was between the two devices on whether SpO2 was above or below 90%. Conclusion OSS3 provided comparable HR and SpO2 accuracy to Masimo in preterm or <2.5 kg infants. Motion artifacts, lack of arterial blood gas comparisons, and lack of racial and ethnic diversity are the study limitations. More OSS3 data on the Lower HR and SpO2 ranges were needed before implementing inpatient use. Key Points M.T., H.D., and B.C. contributed to the conception and design of the study, data collection, data analysis, and manuscript preparation; B.P. and T.M. contributed to the parental consent process and data collection; C.J. contributed to the data processing; Y.S. contributed to the manuscript preparation and review. All authors approved the final manuscript as submitted and agree to be accountable for all aspects of the work. # Heather Day and Micaela Thomas are co-first authors. Received: 02 September 2022 Accepted: 06 March 2023 Article published online: 18 April 2023 © 2023. Thieme. All rights reserved. Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

Verified
Journal Article
Open access
PDF file
BCBelinda Chan
Belinda Chan
Yogen SinghYogen Singh
Yogen Singh
There is no universal consensus on management of patent ductus arteriosus (PDA) in preterm infants and it varies significantly worldwide, even among the clinicians within units. The decision to treat requires a thorough understanding of the clinical status of the patient, clinical evaluation of PDA, echocardiographic diagnosis, and hemodynamic impact of ductal shunt on the pulmonary and systemic circulation. In this article, updated evidence on the efficacy and adverse effects of pharmacological treatment options and expectant management are presented, while highlighting the long-term benefits of PDA treatment remains equivocal and controversial. The authors propose a schematic targeted PDA treatment approach based on gestational and chronological age for practical clinical use, and they emphasize important future directions including advancement in PDA device closure techniques, diagnostic echo-parameters, hemodynamic evaluation to assess the impact on other organs, and understanding the long-term outcomes.

Verified
Journal Article
Open access
PDF file
TATuan-Chen Aw
Tuan-Chen Aw
BCBelinda Chan
Belinda Chan
Yogen SinghYogen Singh
Yogen Singh
Transcatheter device closure of patent ductus arteriosus (PDA) in preterm infants has been proven to be a feasible and safe technique with promising results when compared to surgical ligation. However, managing transport and anaesthesia in extremely premature infants with haemodynamically significant PDA and limited reserves presents unique challenges. This review article focuses on the key considerations throughout the clinical pathway for the PDA device closure, including referral hospital consultation, patient selection, intra- and inter-hospital transport, and anaesthesia management. The key elements encompass comprehensive patient assessment, meticulous airway management, optimised ventilation strategies, precise thermoregulation, patient-tailored sedation protocols, vigilant haemodynamic monitoring, and safe transport measures throughout the pre-operative, intra-operative, and post-operative phases. A multidisciplinary approach enhances the chances of procedure success, improves patient outcomes, and minimises the risk of complications.