Jingzi Hao

Ms. Jingzi Hao


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JLJie Li
Jie Li
JHJingzi Hao
Jingzi Hao
XWXiaoli Wang
Xiaoli Wang
永王永山 王
永山 王
YWYan Wang
Yan Wang
XWXinbo Wang
Xinbo Wang
Fourier ptychographic microscopy (FPM) is a novel technique for computing microimaging that allows imaging of samples such as pathology sections. However, due to the influence of systematic errors and noise, the quality of reconstructed images using FPM is often poor, and the reconstruction efficiency is low. In this paper, a hybrid attention network that combines spatial attention mechanisms with channel attention mechanisms into FPM reconstruction is introduced. Spatial attention can extract fine spatial features and reduce redundant features while, combined with residual channel attention, it adaptively readjusts the hierarchical features to achieve the conversion of low-resolution complex amplitude images to high-resolution ones. The high-resolution images generated by this method can be applied to medical cell recognition, segmentation, classification, and other related studies, providing a better foundation for relevant research.

27 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JLJie Li
Jie Li
HZHe Zhang Zhang
He Zhang Zhang
XWXiaoli Wang
Xiaoli Wang
WHWang Haoming
Wang Haoming
JHJingzi Hao
Jingzi Hao
GBGuanhua Bai
Guanhua Bai
The cornea is an important refractive structure in the human eye. The corneal segmentation technique provides valuable information for clinical diagnoses, such as corneal thickness. Non-contact anterior segment optical coherence tomography (AS-OCT) is a prevalent ophthalmic imaging technique that can visualize the anterior and posterior surfaces of the cornea. Nonetheless, during the imaging process, saturation artifacts are commonly generated due to the tangent of the corneal surface at that point, which is normal to the incident light source. This stripe-shaped saturation artifact covers the corneal surface, causing blurring of the corneal edge, reducing the accuracy of corneal segmentation. To settle this matter, an inpainting method that introduces structural similarity and frequency loss is proposed to remove the saturation artifact in AS-OCT images. Specifically, the structural similarity loss reconstructs the corneal structure and restores corneal textural details. The frequency loss combines the spatial domain with the frequency domain to ensure the overall consistency of the image in both domains. Furthermore, the performance of the proposed method in corneal segmentation tasks is evaluated, and the results indicate a significant benefit for subsequent clinical analysis.