Nazifi Sani Shuaibu

Dr. Nazifi Sani Shuaibu

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2023 in Cancers
Verified
Journal Article
Open access
PDF file
Nazifi Sani ShuaibuNazifi Sani Shuaibu
Nazifi Sani Shuaibu
WZWei Zhou
Wei Zhou
BIBalarabe B. Ismail
Balarabe B. Ismail
YZYongkui Zhang
Yongkui Zhang
ZCZhijun Chen
Zhijun Chen
Xiaozhi WangXiaozhi Wang
Xiaozhi Wang
(1) Background: lung cancer is the world’s deadliest cancer, but early diagnosis helps to improve the cure rate and thus reduce the mortality rate. Annual low-dose computed tomography (LD-CT) screening is an efficient lung cancer-screening program for a high-risk population. However, LD-CT has often been characterized by a higher degree of false-positive results. To meet these challenges, a volatolomic approach, in particular, the breath volatile organic compounds (VOCs) fingerprint analysis, has recently received increased attention for its application in early lung cancer screening thanks to its convenience, non-invasiveness, and being well tolerated by patients. (2) Methods: a LC-MS/MS-based volatolomics analysis was carried out according to P/N 5046800 standard based breath analysis of VOC as novel cancer biomarkers for distinguishing early-stage lung cancer from the healthy control group. The discriminatory accuracy of identified VOCs was assessed using subject work characterization and a random forest risk prediction model. (3) Results: the proposed technique has good performance compared with existing approaches, the differences between the exhaled VOCs of the early lung cancer patients before operation, three to seven days after the operation, as well as four to six weeks after operation under fasting and 1 h after the meal were compared with the healthy controls. The results showed that only 1 h after a meal, the concentration of seven VOCs, including 3-hydroxy-2-butanone (TG-4), glycolaldehyde (TG-7), 2-pentanone (TG-8), acrolein (TG-11), nonaldehyde (TG-19), decanal (TG-20), and crotonaldehyde (TG-22), differ significantly between lung cancer patients and control, with the invasive adenocarcinoma of the lung (IAC) having the most significant difference. (4) Conclusions: this novel, non-invasive approach can improve the detection rate of early lung cancer, and LC-MS/MS-based breath analysis could be a promising method for clinical application.

23 December 2022 in Analytical Chemistry
Verified
Journal Article
Closed access
FCFengjian Chu
Fengjian Chu
GZGaosheng Zhao
Gaosheng Zhao
WLWangyu Li
Wangyu Li
WWWei Wei
Wei Wei
WCWeiwei Chen
Weiwei Chen
Xiaozhi WangXiaozhi Wang
Xiaozhi Wang

7 December 2023 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
YLYulu Liu
Yulu Liu
XYXi Yang
Xi Yang
Jie LiJie Li
Jie Li
Zhang KaihangZhang Kaihang
Zhang Kaihang
HWHaobin Wang
Haobin Wang
Xiaozhi WangXiaozhi Wang
Xiaozhi Wang

9 July 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
ASO ALI ABDALMOHAMMED SHATERIASO ALI ABDALMOHAMMED SHATERI
ASO ALI ABDALMOHAMMED SHATERI
SFSalar Fatah
Salar Fatah
FZFengling Zhuo
Fengling Zhuo
Nazifi Sani ShuaibuNazifi Sani Shuaibu
Nazifi Sani Shuaibu
CCChuanrui Chen
Chuanrui Chen
Xiaozhi WangXiaozhi Wang
Xiaozhi Wang
Triboelectric nanogenerators (TENGs) hold significant potential for decentralized energy harvesting; however, their dependence on rotational mechanical energy often limits their ability to harness ubiquitous horizontal motion in real-world applications. Here, a single horizontal linear-to-rotational triboelectric nanogenerator (SHLR-TENG) is presented, designed to efficiently convert linear motion into rotational energy using a robust gear system, enabling a high voltage and reliable full cycle of alternating current (AC). The device features a radially patterned disk with triboelectric layers composed of polyimide. The SHLR-TENG achieves a peak-to-peak voltage of 1420 V, a short-circuit current of 117 µA, and an average power output of 41.5 mW, with a surface charge density of 110 µC/m2. Moreover, it demonstrates a power density per unit volume of 371.2 W·m−3·Hz−1. The device retains 80% efficiency after 1.5 million cycles, demonstrating substantial durability under mechanical stress. These properties enable the SHLR-TENG to directly power commercial LEDs and low-power circuits without the need for energy storage. This study presents an innovative approach to sustainable energy generation by integrating horizontal motion harvesting with rotational energy conversion. The compact and scalable design of the SHLR-TENG, coupled with its resilience to humidity (20–90% RH) and temperature fluctuations (10–70 °C), positions it as a promising next-generation energy source for Internet of Things (IoT) devices and autonomous systems.

4 March 2024 in Environmental Sciences Europe
Verified
Journal Article
Open access
PDF file
Nazifi Sani ShuaibuNazifi Sani Shuaibu
Nazifi Sani Shuaibu
CQChenghua Qin
Chenghua Qin
FCFengjian Chu
Fengjian Chu
BIBalarabe B. Ismail
Balarabe B. Ismail
AIAmmar Muhammad Ibrahim
Ammar Muhammad Ibrahim
Xiaozhi WangXiaozhi Wang
Xiaozhi Wang
Background: In recent decades, there has been an increasing global preoccupation with atmospheric volatile organic compounds (VOCs). Given the significant impact of VOCs as pollutants and essential precursors of ozone (O3) in urban and industrial areas, it is imperative to identify and quantify the sources of their emissions to facilitate the development and implementation of effective environmental control strategies. Methods: A mobile laboratory vehicle equipped with a single-photon ionization–time-of-flight mass spectrometer (SPI–TOFMS) and a navigation system was employed to establish the traceability of VOCs that contribute to the formation of ozone in Suzhou Industrial Park. The method exhibited a favorable detection limit of 0.090 ppbv, accompanied by a mass resolution of 1500 for the instrument and a correlation coefficient ≥ 0.990. A positive matrix factorization (PMF) model was utilized to determine the source appointment of the VOCs. Results: The study tentatively traced and identified the VOCs emissions source and their contribution to ozone formation in Suzhou. Using the PMF model, the sources of VOCs were profiled: three primary sources of VOCs were identified, namely, vehicular emissions, an industrial solvent, and biofuel combustion. Alkanes groups were found to be the most abundant VOCs species, accounting for 60% of the total VOCs, followed by aromatics and alkenes. Maximum incremental reactivity (MIR) quantifies the impact of photochemical reaction mechanism on the potential ozone formation. Conclusions: The findings of this study complement existing knowledge on the pollution status of atmospheric VOCs and highlight the correlation with ozone formation potential in Suzhou. The aforementioned sources were identified as the primary factors responsible for the pollution in Suzhou. The successful implementation of SPI–TOFMS has demonstrated a promising methodology that is well-suited for the real-time and online monitoring of VOCs in the atmosphere. In addition, a library for identifying VOC fingerprints from the same plant was established. This library serves as a comprehensive resource for establishing on-site VOC traceability, estimating source apportionment, and evaluating their impact on ozone formation.

26 July 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
YPYuanjiang Pan
Yuanjiang Pan
WWWei Wei
Wei Wei
Nazifi Sani ShuaibuNazifi Sani Shuaibu
Nazifi Sani Shuaibu
HFHongru Feng
Hongru Feng
Xiaozhi WangXiaozhi Wang
Xiaozhi Wang
YPYuanjiang Pan
Yuanjiang Pan
Sensitive and accurate detection of biomolecules by multiplexed methods is important for disease diagnosis, drug research, and biochemical analysis. Mass spectrometry has the advantages of high sensitivity, high throughput, and high resolution, making it ideal for biomolecular sensing. As a result of the development of atmospheric pressure mass spectrometry, researchers have been able to use a variety of means to identify target biomolecules and recognize the converted signals by mass spectrometry. In this review, three main approaches and tools are summarized for mass spectrometry sensing and biopsy techniques, including array biosensing, probe/pen-based mass spectrometry, and other biosensor–mass spectrometry coupling techniques. Portability and practicality of relevant mass spectrometry sensing methods are reviewed, together with possible future directions to promote the advancement of mass spectrometry for target identification of biomolecules and rapid detection of real biological samples.