Uta Sager

Dr. Uta Sager

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2017 in Energies
Verified
Journal Article
Open access
PDF file
IGImen Ghouma
Imen Ghouma
Mejdi JeguirimMejdi Jeguirim
Mejdi Jeguirim
USUta Sager
Uta Sager
Lionel LimousyLionel Limousy
Lionel Limousy
Simona BENNICISimona BENNICI
Simona BENNICI
AOAbdelmottaleb OUEDERNI
Abdelmottaleb OUEDERNI
The treatment of NOx from automotive gas exhaust has been widely studied, however the presence of low concentrations of NOx in confined areas is still under investigation. As an example, the concentration of NO2 can approximate 0.15 ppmv inside vehicles when people are driving on highways. This interior pollution becomes an environmental problem and a health problem. In the present work, the abatement of NO2 immission is studied at room temperature. Three activated carbons (ACs) prepared by physical (CO2 or H2O) or chemical activation (H3PO4) are tested as adsorbents. The novelty of this work consists in studying the adsorption of NO2 at low concentrations that approach real life immission concentrations and is experimentally realizable. The ACs present different structural and textural properties as well as functional surface groups, which induce different affinities with NO2. The AC prepared using water vapor activation presents the best adsorption capacity, which may originate from a more basic surface. The presence of a mesoporosity may also influence the diffusion of NO2 inside the carbon matrix. The high reduction activity of the AC prepared from H3PO4 activation is explained by the important concentration of acidic groups on its surface.

16 January 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
Stefan SchumacherStefan Schumacher
Stefan Schumacher
ACAnna Caspari
Anna Caspari
USUte Schneiderwind
Ute Schneiderwind
KSKatharina Staack
Katharina Staack
USUta Sager
Uta Sager
Christof AsbachChristof Asbach
Christof Asbach
Air cleaners with activated carbon (AC) filters for the adsorption of gaseous pollutants are often used to improve indoor air quality. As formaldehyde is a common and health-relevant indoor air pollutant, many testing standards for air cleaners, such as GB/T 18801:2015, require the cleaning efficacy to be tested with this substance. This often persuades manufacturers to optimize the employed filters specifically for formaldehyde. However, in regions where indoor formaldehyde levels are far below the guideline values, other gaseous pollutants might be more relevant. Thus, the question arises of whether the optimization for formaldehyde can have a negative impact on the adsorption of other gases. To address this question, the clean air delivery rate (CADR) of an air cleaner was determined for different test gases with either a standard AC filter or an AC filter modified for improved formaldehyde adsorption. Although the modified AC filter performed substantially better for formaldehyde, a strong reduction in the CADR was observed for toluene and nitrogen dioxide. This is a drawback for situations in which these gases are more problematic than formaldehyde. The findings suggest using either specialized filters for different applications or blends of different adsorbants to find the best compromise for the most relevant pollutants.

1 March 2021 in Building and Environment
Verified
Journal Article
Closed access
RLRoman Ligotski
Roman Ligotski
KGKai-Daniel Gilles
Kai-Daniel Gilles
MRMats Roehnert
Mats Roehnert
USUta Sager
Uta Sager
CAChristof Asbach
Christof Asbach
FSFrank Schmidt
Frank Schmidt

25 June 2010 in Chemical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
USUta Sager
Uta Sager
FSF. Schmidt
F. Schmidt

1 March 2009 in Adsorption Science & Technology
Verified
Journal Article
Open access
USUta Sager
Uta Sager
FSFrank Schmidt
Frank Schmidt
Noxious gases and odours in cabin air are reduced by activated carbon filters. However, the adsorption process involved in cabin air filtration is very complex because of the large number of influencing parameters. Some important parameters are changes in the input concentrations and surrounding conditions. Furthermore, the presence of different substances leads to their mutual influence on the respective adsorption processes. The separation of nitrogen oxides is an especial focus of discussion in Germany at present because of decreasing ambient exposure limits. One part of the study presented herein deals with the binary adsorption of nitrogen dioxide in humid air at varying NO2 input concentrations, relative humidity and temperature. In order to obtain more information about this process, after initial validation of the test procedure employed, breakthrough curves of NO2 have been undertaken in the present study. In the second part of the study, the influence of a third adsorptive (ozone) on the adsorption of nitrogen dioxide has been investigated.

1 June 2016 in Adsorption Science & Technology
Verified
Journal Article
Open access
USUta Sager
Uta Sager
EDEckhard Däuber
Eckhard Däuber
DBDieter Bathen
Dieter Bathen
CAChristof Asbach
Christof Asbach
FSFrank Schmidt
Frank Schmidt
WSWolfgang Schmidt
Wolfgang Schmidt
The reduction of NO2 in air at ambient temperatures with activated carbons can be increased by the infiltration of metal oxide nanoparticles into the sorbents. The NO2 is first adsorbed to the activated carbon and subsequently catalytically reduced to physiologically neutral substances by the metal oxides. The catalytic reduction at ambient temperatures is rather slow. In a former study concerning the application in cabin air filters, it was shown that the modification of activated carbon with 5 wt% CuO/ZnO leads to reduced breakthrough of NO2 and that the adsorbent was able to regenerate between repeated NO2 adsorption cycles. Here we show that the efficiency of the sorbent can be more than doubled by increasing the metal oxide infiltration to 20 wt% whereas a further increase in loading yields no additional improvement, due to a partial transformation of the oxidic compounds.