Hendrik Ballhausen

Dr. Hendrik Ballhausen

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2018 in Strahlentherapie und Onkologie
Verified
Journal Article
Closed access
PDF file
HBHendrik Ballhausen
Hendrik Ballhausen
MLMinglun Li
Minglun Li
UGUte Ganswindt
Ute Ganswindt
CBClaus Belka
Claus Belka

10 July 2015 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
CAClaudia Andrä
Claudia Andrä
JRJosefine Rauch
Josefine Rauch
Minglun LiMinglun Li
Minglun Li
UGUte Ganswindt
Ute Ganswindt
CBClaus Belka
Claus Belka
FRFalk Roeder
Falk Roeder
To report our results with postoperative or definitive radiation therapy in head and neck sarcomas. We performed a retrospective analysis of 26 patients suffering from head and neck sarcomas, who received postoperative or definitive radiation therapy between 2003 and 2012. Median age was 64 years (19–88) and 69 % were male. Tumor locations were skull (including skin) in 31 %, paranasal sinus/orbita in 27 % and neck (including pharynx/larynx) in 42 %. Median tumor size was 4.6 cm (1-12 cm). 22 patients (85 %) presented in primary situation. Stage at presentation (UICC 7th for soft tissue sarcomas) was as follows: Ia:4 %, IIa:50 %, IIb:15 %, III:31 %. All except one patient suffered from high grade lesions (G2/3 FNCLCC), predominantly angiosarcoma (35 %), MFH (19 %) and synovial sarcoma (15 %). Surgery was performed in 21 pts (81 %), resulting in free margins in 10 (38 %), microscopically positive margins in 6 (23 %) and gross residual disease in 5 (19 %). Median dose to the primary tumor region was 66Gy (45-72Gy) in conventional fractionation, using 3D-CRT in 65 %, IMRT in 27 % and electrons in 8 %. 50 % of the patients also received sequential chemotherapy. Median follow up was 39 months (8–136). We observed three local recurrences, transferring into estimated 3- and 5-year local control rates of 86 %. One additional patient failed distantly, resulting in 3- and 5-year freedom from treatment failure rates of 82 %. Four patients have deceased, transferring into 3- and 5-year overall survival rates of 88 % and 82 %, respectively. Only two of the four deaths were sarcoma related. Maximum acute toxicity (CTCAE 3.0) was grade 1 in 27 % of the patients, grade 2 in 50 % and grade 3 in 23 %. Severe acute toxicity was mainly represented by mucositis and dysphagia. Maximum late toxicity was grade 1 in 31 %, grade 2 in 15 % and grade 3 in 19 % of the patients. Severe late toxicity included skin ulceration (n = 1), dysphagia with persistent tube dependency (n = 1), persistent sinusitis (n = 1) and hearing loss (n = 2). Excellent local control and overall survival rates can be achieved with postoperative or definitive radiation therapy with acceptable acute and late toxicities in patients suffering from sarcomas of the head and neck region.

9 April 2015 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
Minglun LiMinglun Li
Minglun Li
HBHendrik Ballhausen
Hendrik Ballhausen
NHNina-Sophie Hegemann
Nina-Sophie Hegemann
UGUte Ganswindt
Ute Ganswindt
Farkhad ManapovFarkhad Manapov
Farkhad Manapov
CBClaus Belka
Claus Belka
The accuracy of the Elekta Clarity™ three-dimensional ultrasound system (3DUS) was assessed for prostate positioning and compared to seed- and bone-based positioning in kilo-voltage cone-beam computed tomography (CBCT) during a definitive radiotherapy. The prostate positioning of 6 patients, with fiducial markers implanted into the prostate, was controlled by 3DUS and CBCT. In total, 78 ultrasound scans were performed trans-abdominally and compared to bone-matches and seed-matches in CBCT scans. Setup errors detected by the different modalities were compared. Systematic and random errors were analysed, and optimal setup margins were calculated. The discrepancy between 3DUS and seed-match in CBCT was −0.2 ± 2.7 mm laterally, −1.9 ± 2.3 mm longitudinally and 0.0 ± 3.0 mm vertically and significant only in longitudinal direction. Using seed-match as reference, systematic errors of 3DUS were 1.3 mm laterally, 0.8 mm longitudinally and 1.4 mm vertically, and random errors were 2.5 mm laterally, 2.3 mm longitudinally, and 2.7 mm vertically. No significant difference could be detected for 3DUS in comparison to bone-match in CBCT. 3DUS is feasible for image guidance for patients with prostate cancer and appears comparable to CBCT based image guidance in the retrospective study. While 3DUS offers some distinct advantages such as no need of invasive fiducial implantation and avoidance of extra radiation, its disadvantages include the operator dependence of the technique and dependence on sufficient bladder filling. Further study of 3DUS for image guidance in a large patient cohort is warranted.

14 October 2024 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
HBHendrik Ballhausen
Hendrik Ballhausen
SCStefanie Corradini
Stefanie Corradini
CBClaus Belka
Claus Belka
DBDan Bogdanov
Dan Bogdanov
LBLuca Boldrini
Luca Boldrini
SMSebastian Marschner
Sebastian Marschner
In multicentric studies, data sharing between institutions might negatively impact patient privacy or data security. An alternative is federated analysis by secure multiparty computation. This pilot study demonstrates an architecture and implementation addressing both technical challenges and legal difficulties in the particularly demanding setting of clinical research on cancer patients within the strict European regulation on patient privacy and data protection: 24 patients from LMU University Hospital in Munich, Germany, and 24 patients from Policlinico Universitario Fondazione Agostino Gemelli, Rome, Italy, were treated for adrenal gland metastasis with typically 40 Gy in 3 or 5 fractions of online-adaptive radiotherapy guided by real-time MR. High local control (21% complete remission, 27% partial remission, 40% stable disease) and low toxicity (73% reporting no toxicity) were observed. Median overall survival was 19 months. Federated analysis was found to improve clinical science through privacy-friendly evaluation of patient data in the European health data space.

15 May 2014 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
HBHendrik Ballhausen
Hendrik Ballhausen
MRMichael Reiner
Michael Reiner
UGUte Ganswindt
Ute Ganswindt
CBClaus Belka
Claus Belka
MSMatthias Söhn
Matthias Söhn
Metal implants, surgical clips and other foreign bodies may cause ‘streaking’ or ‘star’ artifacts in computed tomography (CT) reconstructions, for example in the vicinity of dental restorations or hip implants. The deteriorated image quality complicates contouring and has an adverse effect on quantitative planning in external beam therapy.

18 March 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
HBHendrik Ballhausen
Hendrik Ballhausen
MRM Reiner
M Reiner
SKS Kantz
S Kantz
CBC Belka
C Belka
MSM Söhn
M Söhn
The purpose of this paper is to understand intrafraction movement as a stochastic process driven by random external forces. The hypothetically proposed three-dimensional random walk model has significant impact on optimal PTV margins and offers a quantitatively correct explanation of experimental findings. Properties of the random walk are calculated from first principles, in particular fraction-average population density distributions for displacements along the principal axes. When substituted into the established optimal margin recipes these fraction-average distributions yield safety margins about 30% smaller as compared to the suggested values from end-of-fraction gaussian fits. Stylized facts of a random walk are identified in clinical data, such as the increase of the standard deviation of displacements with the square root of time. Least squares errors in the comparison to experimental results are reduced by about 50% when accounting for non-gaussian corrections from the random walk model.