The assessment of resting perfusion measures (mean transit time, cerebral blood flow, and cerebral blood volume) with magnetic resonance imaging currently requires the presence of a susceptibility contrast agent such as gadolinium. Here, we present an initial comparison between perfusion measures obtained using hypoxia‐induced deoxyhemoglobin and gadolinium in healthy study participants. We hypothesize that resting cerebral perfusion measures obtained using precise changes of deoxyhemoglobin concentration will generate images comparable to those obtained using a clinical standard, gadolinium. Eight healthy study participants were recruited (6F; age 23–60). The study was performed using a 3‐Tesla scanner with an eight‐channel head coil. The experimental protocol consisted of a high‐resolution T1‐weighted scan followed by two BOLD sequence scans in which each participant underwent a controlled bolus of transient pulmonary hypoxia, and subsequently received an intravenous bolus of gadolinium. The resting perfusion measures calculated using hypoxia‐induced deoxyhemoglobin and gadolinium yielded maps that looked spatially comparable. There was no statistical difference between methods in the average voxel‐wise measures of mean transit time, relative cerebral blood flow and relative cerebral blood volume, in the gray matter or white matter within each participant. We conclude that perfusion measures generated with hypoxia‐induced deoxyhemoglobin are spatially and quantitatively comparable to those generated from a gadolinium injection in the same healthy participant.
22 December 2023 in Journal of Magnetic Resonance Imaging
Background: Cerebrovascular reactivity (CVR) is a measure of the change in cerebral blood flow (CBF) in response to a vasoactive challenge. It is a useful indicator of the brain's vascular health.Purpose: To evaluate the factors that influence successful and unsuccessful CVR examinations using precise arterial and end‐tidal partial pressure of CO2 control during blood oxygen level–dependent (BOLD) MRI.Study Type: Retrospective.Subjects: Patients that underwent a CVR between October 2005 and May 2021 were studied (total of 1162 CVR examinations). The mean (±SD) age was 46.1 (±18.8) years, and 352 patients (43%) were female.Field Strength/Sequence: 3 T; T1‐weighted images, T2*‐weighed two‐dimensional gradient‐echo sequence with standard echo‐planar readout.Assessment: Measurements were obtained following precise hypercapnic stimuli using BOLD MRI as a surrogate of CBF. Successful CVR examinations were defined as those where: 1) patients were able to complete CVR testing, and 2) a clinically useful CVR map was generated. Unsuccessful examinations were defined as those where patients were not able to complete the CVR examination or the CVR maps were judged to be unreliable due to, for example, excessive head motion, and poor PETCO2 targeting.Statistical Analysis: Successful and unsuccessful CVR examinations between hypercapnic stimuli, and between different patterns of stimulus were compared with Chi‐Square tests. Interobserver variability was determined by using the intraclass correlation coefficient (P < 0.05 is significant).Results: In total 1115 CVR tests in 662 patients were included in the final analysis. The success rate of generating CVR maps was 90.8% (1012 of 1115). Among the different hypercapnic stimuli, those containing a step plus a ramp protocol was the most successful (95.18%). Among the unsuccessful examinations (9.23%), most were patient related (89.3%), the most common of which was difficulty breathing.Data Conclusion: CO2‐BOLD MRI CVR studies are well tolerated with a high success rate.Evidence Level: 4Technical Efficacy: Stage 3
Introduction: Use of contrast in determining hemodynamic measures requires the deconvolution of an arterial input function (AIF) selected over a voxel in the middle cerebral artery to calculate voxel wise perfusion metrics. Transfer function analysis (TFA) offers an alternative analytic approach that does not require identifying an AIF. We hypothesised that TFA metrics Gain, Lag, and their ratio, Gain/Lag, correspond to conventional AIF resting perfusion metrics relative cerebral blood volume (rCBV), mean transit time (MTT) and relative cerebral blood flow (rCBF), respectively.Methods: 24 healthy participants (17 M) and 1 patient with steno-occlusive disease were recruited. We used non-invasive transient hypoxia-induced deoxyhemoglobin as an MRI contrast. TFA and conventional AIF analyses were used to calculate averages of whole brain and smaller regions of interest.Results: Maps of these average metrics had colour scales adjusted to enhance contrast and identify areas of high congruence. Regional gray matter/white matter (GM/WM) ratios for MTT and Lag, rCBF and Gain/Lag, and rCBV and Gain were compared. The GM/WM ratios were greater for TFA metrics compared to those from AIF analysis indicating an improved regional discrimination.Discussion: Resting perfusion measures generated by The BOLD analysis resulting from a transient hypoxia induced variations in deoxyhemoglobin analyzed by TFA are congruent with those analyzed by conventional AIF analysis.
In patients with sickle cell disease (SCD), the delivery of oxygen to the brain is compromised by anemia, abnormal rheology, and steno‐occlusive vascular disease. Successful compensation depends on an increase in oxygen supply such as that provided by an increase in cerebral blood flow (CBF). We used magnetic resonance imaging to provide a high‐resolution assessment of the ability of SCD patients to respond to a vasoactive stimulus in middle, anterior, and posterior cerebral artery territories for both white and gray matter. Cerebrovascular reactivity (CVR) was measured as the blood oxygen level dependent signal (a surrogate for CBF) response to an increase in the end tidal partial pressure of CO2 (PETCO2). The dynamic aspect of the response was measured as the time constant of the first order response kinetics (tau). To confirm and support these findings we used an alternative examination of the response, transfer function analysis (TFA), to measure the responsiveness (gain), the speed of response (phase), and the consistency of the response over time (coherence). We tested 34 patients with SCD and compared the results to those of 24 healthy controls participants. The results from a three‐way ANOVA showed that patients with SCD have reduced CVR (p < 0.001) and lower coherence (p < 0.001) in gray matter and white matter and reduced gain in gray matter only (p < 0.001). In terms of the speed of the response to CO2, tau (p < 0.001) and TFA phase (p < 0.001) were increased in SCD patients compared to healthy control subjects. These findings show that the cerebrovascular responsiveness to CO2 in patients with SCD is both decreased and slowed compared to healthy controls.
26 August 2023 in Journal of Cerebral Blood Flow & Metabolism
Evaluation of cerebrovascular reactivity (CVR) to hypo- and hypercapnia is a valuable test for the assessment of vasodilatory reserve. While hypercapnia-induced CVR testing is usually performed at normoxia, mild hyperoxia may increase tolerability of hypercapnia by reducing the ventilatory distress. However, the effects of mild hyperoxia on CVR was unknown. We therefore recruited 21 patients with a range of steno-occlusive diseases and 12 healthy participants who underwent a standardized 13-minute step plus ramp CVR test with a carbon dioxide gas challenge at the subject’s resting end-tidal partial pressure of oxygen or at mild hyperoxia (PetO2 = 150 mmHg) depending on to which group they were assigned. In 11 patients, the second CVR test was at normoxia to examine test-retest differences. CVR was defined as % Δ Signal/ΔPetCO2. We found that there was no significant difference between CVR test results conducted at normoxia and at mild hyperoxia for participants in Groups 1 and 2 for the step and ramp portion. We also found no difference between test and retest CVR at normoxia for patients with cerebrovascular pathology (Group 3) for step and ramp portion. We concluded normoxic CVR is repeatable, and that mild hyperoxia does not affect CVR.