Aoife Morrin

Prof. Aoife Morrin

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2006 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
XLXiliang Luo
Xiliang Luo
AMAoife Morrin
Aoife Morrin
AKAnthony Killard
Anthony Killard
MSMalcolm R. Smyth
Malcolm R. Smyth

15 December 2008 in Talanta
Verified
Journal Article
Closed access
KCK Crowley
K Crowley
AMAoife Morrin
Aoife Morrin
AHA Hernandez
A Hernandez
EOE Omalley
E Omalley
PWP Whitten
P Whitten
AKAnthony Killard
Anthony Killard

8 January 2010 in The Analyst
Verified
Journal Article
Closed access
PDF file
LGLaura Gonzalez-Macia
Laura Gonzalez-Macia
AMAoife Morrin
Aoife Morrin
MSMalcolm R. Smyth
Malcolm R. Smyth
AKAnthony Killard
Anthony Killard
Advanced printing and deposition methodologies are revolutionising the way biological molecules are deposited and leading to changes in the mass production of biosensors and biodevices. This revolution is being delivered principally through adaptations of printing technologies to device fabrication, increasing throughputs, decreasing feature sizes and driving production costs downwards. This review looks at several of the most relevant deposition and patterning methodologies that are emerging, either for their high production yield, their ability to reach micro- and nano-dimensions, or both. We look at inkjet, screen, microcontact, gravure and flexographic printing as well as lithographies such as scanning probe, photo- and e-beam lithographies and laser printing. We also take a look at the emerging technique of plasma modification and assess the usefulness of these for the deposition of biomolecules and other materials associated with biodevice fabrication.

1 February 2008 in Analytica Chimica Acta
Verified
Journal Article
Closed access
AAAdriano Ambrosi
Adriano Ambrosi
AMAoife Morrin
Aoife Morrin
MSMalcolm R. Smyth
Malcolm R. Smyth
AKAnthony Killard
Anthony Killard

1 July 2007 in Langmuir
Verified
Journal Article
Closed access
ONOrawan Ngamna
Orawan Ngamna
AMAoife Morrin
Aoife Morrin
AKAnthony Killard
Anthony Killard
SMSimon E. Moulton
Simon E. Moulton
MSMalcolm R. Smyth
Malcolm R. Smyth
GWGordon G. Wallace
Gordon G. Wallace

1 August 2006 in Analytica Chimica Acta
Verified
Journal Article
Open access
XLXiliang Luo
Xiliang Luo
AKAnthony Killard
Anthony Killard
AMAoife Morrin
Aoife Morrin
MSMalcolm R. Smyth
Malcolm R. Smyth
A biosensor with improved performance was developed through the immobilization of horseradish peroxidase (HRP) onto electropolymerized polyaniline (PANI) films doped with carbon nanotubes (CNTs). The effects of electropolymerization cycle and CNT concentration on the response of the biosensor toward H2O2 were investigated. It was found that the application of CNTs in the biosensor system could increase the amount and stability of the immobilized enzyme, and greatly enhanced the biosensor response. Compared with the biosensor without CNTs, the proposed biosensor exhibited enhanced stability and approximately eight-fold sensitivity. A linear range from 0.2 to 19 microM for the detection of H2O2 was observed for the proposed biosensor, with a detection limit of 68 nM at a signal-to-noise ratio of 3 and a response time of less than 5s.