Jiangfeng Wu

Dr. Jiangfeng Wu

The Affiliated Dongyang Hospital of Wenzhou Medical University
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in Ultrasound Quarterly
Verified
Journal Article
Open access
JWJiangfeng Wu
Jiangfeng Wu
YWYunlai Wang
Yunlai Wang
AZAnli Zhao
Anli Zhao
ZWZhengping Wang
Zhengping Wang
Chest radiography is the primary imaging modality used for the assessment of neonatal respiratory distress syndrome (NRDS) in newborns. However, excessively exposing a growing neonate to harmful ionizing radiation may have long-term consequences. Some studies have shown that lung ultrasound (LUS) is helpful in the diagnosis of NRDS. A comprehensive search was carried out using PubMed, Embase, and the Cochrane Library to identify studies in which newborns with clinically suspected NRDS were assessed by LUS. Two investigators independently screened the literature and extracted the data. Any discrepancies were resolved via discussion with the senior author. Study quality was assessed by the Quality Assessment of Diagnostic Accuracy Studies 2 tool, and pooled sensitivity and specificity of various LUS findings for diagnosing NRDS were determined. Summary receiver operating characteristic curve was used to assess the overall performance of LUS. Ten studies with a total of 887 neonates were included in this meta-analysis. There was significant heterogeneity across the included studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for the diagnosis of NRDS using LUS were 0.92 (95% confidence interval [CI], 0.89–0.94), 0.95 (95% CI, 0.93–0.97), 20.23 (95% CI, 8.54–47.92), 0.07 (95% CI, 0.03–0.14), and 455.30 (95% CI, 153.01–1354.79), respectively. Furthermore, the summary receiver operating characteristic area under the curve was calculated to be 0.9888. The main LUS characteristics of NRDS include bilateral white lung, pleural line abnormalities, and lung consolidation. In summary, LUS is a highly valuable diagnostic technology that complements chest radiography in the diagnosis and follow-up monitoring of NRDS.

12 December 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
YGYinghong Guo
Yinghong Guo
JWJiangfeng Wu
Jiangfeng Wu
YWYunlai Wang
Yunlai Wang
YJYun Jin
Yun Jin
(1) Objective: To evaluate the performance of ultrasound-based radiomics in the preoperative prediction of human epidermal growth factor receptor 2-positive (HER2+) and HER2− breast carcinoma. (2) Methods: Ultrasound images from 309 patients (86 HER2+ cases and 223 HER2− cases) were retrospectively analyzed, of which 216 patients belonged to the training set and 93 patients assigned to the time-independent validation set. The region of interest of the tumors was delineated, and the radiomics features were extracted. Radiomics features underwent dimensionality reduction analyses using the intra-class correlation coefficient (ICC), Mann–Whitney U test, and the least absolute shrinkage and selection operator (LASSO) algorithm. The radiomics score (Rad-score) for each patient was calculated through a linear combination of the nonzero coefficient features. The support vector machine (SVM), K nearest neighbors (KNN), logistic regression (LR), decision tree (DT), random forest (RF), naive Bayes (NB) and XGBoost (XGB) machine learning classifiers were trained to establish prediction models based on the Rad-score. A clinical model based on significant clinical features was also established. In addition, the logistic regression method was used to integrate Rad-score and clinical features to generate the nomogram model. The leave-one-out cross validation (LOOCV) method was used to validate the reliability and stability of the model. (3) Results: Among the seven classifier models, the LR achieved the best performance in the validation set, with an area under the receiver operating characteristic curve (AUC) of 0.786, and was obtained as the Rad-score model, while the RF performed the worst. Tumor size showed a statistical difference between the HER2+ and HER2− groups (p = 0.028). The nomogram model had a slightly higher AUC than the Rad-score model (AUC, 0.788 vs. 0.786), but no statistical difference (Delong test, p = 0.919). The LOOCV method yielded a high median AUC of 0.790 in the validation set. (4) Conclusion: The Rad-score model performs best among the seven classifiers. The nomogram model based on Rad-score and tumor size has slightly better predictive performance than the Rad-score model, and it has the potential to be utilized as a routine modality for preoperatively determining HER2 status in BC patients non-invasively.

28 August 2024 in Annals of Medicine
Verified
Journal Article
Open access
JWJiangfeng Wu
Jiangfeng Wu
LGLifang Ge
Lifang Ge
YGYinghong Guo
Yinghong Guo
DXDong Xu
Dong Xu
ZWZhengping Wang
Zhengping Wang
The tumor burden within the axillary lymph nodes (ALNs) constitutes a pivotal factor in breast cancer, serving as the primary determinant for treatment decisions and exhibiting a close correlation with prognosis. This study aimed to investigate the potential of ultrasound-based radiomics and clinical characteristics in non-invasively distinguishing between low tumor burden (1-2 positive nodes) and high tumor burden (more than 2 positive nodes) in patients with node-positive breast cancer. A total of 215 patients with node-positive breast cancer, who underwent preoperative ultrasound examinations, were enrolled in this study. Among these patients, 144 cases were allocated to the training set, 37 cases to the validation set, and 34 cases to the testing set. Postoperative histopathology was used to determine the status of ALN tumor burden. The region of interest for breast cancer was delineated on the ultrasound image. Nine models were developed to predict high ALN tumor burden, employing a combination of three feature screening methods and three machine learning classifiers. Ultimately, the optimal model was selected and tested on both the validation and testing sets. In addition, clinical characteristics were screened to develop a clinical model. Furthermore, Shapley additive explanations (SHAP) values were utilized to provide explanations for the machine learning model. During the validation and testing sets, the models demonstrated area under the curve (AUC) values ranging from 0.577 to 0.733 and 0.583 to 0.719, and accuracies ranging from 64.9% to 75.7% and 64.7% to 70.6%, respectively. Ultimately, the Boruta_XGB model, comprising five radiomics features, was selected as the final model. The AUC values of this model for distinguishing low from high tumor burden were 0.828, 0.715, and 0.719 in the training, validation, and testing sets, respectively, demonstrating its superiority over the clinical model. The developed radiomics models exhibited a significant level of predictive performance. The Boruta_XGB radiomics model outperformed other radiomics models in this study.

4 August 2021 in Medical Ultrasonography
Verified
Journal Article
Closed access
PDF file
JWJiangfeng Wu
Jiangfeng Wu
LGLijing Ge
Lijing Ge
XWXiaoyun Wang
Xiaoyun Wang
YJYun Jin
Yun Jin
Aims: To evaluate the effect of point-of-care ultrasound (POCUS) for the diagnosis of an abscess and to compare the diagnostic accuracy of POCUS and physical examination (PE) in paediatric patients with skin and soft tissue infections (SSTI) in the emergency department.Material and methods: A comprehensive literature search was carried out to identify Englishlanguage studies on POCUS for differentiating an abscess from cellulitis in paediatric patients with SSTI. The quality of the study was assessed by the Quality Assessment of Diagnostic Accuracy Studies 2 tool, and pooled sensitivity and specificity of various POCUS findings were determined.Results: Seven studies with a total of 870 patients were included. There was significant heterogeneity across the included studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio for the diagnosis of abscess by POCUS were 0.90 (95% confidence interval [CI], 0.82-0.95), 0.80 (95% CI, 0.72-0.86), 4.5 (95% CI, 3.1-6.4), 0.13 (95% CI, 0.07-0.23), and 36 (95% CI, 17-75), respectively, with an area under the curve (AUC) was 0.89 (95% CI, 0.86-0.91). Four studies provided data regarding the PE method. The pooled sensitivity, specificity, and AUC of PE for the abscess were 0.84 (95% CI, 0.80-0.88), 0.69 (95% CI, 0.62-0.76), and 0.85 (95% CI, 0.81-0.88).Conclusions: POCUS is useful in identifying abscesses in paediatric patients with SSTI in emergency department, especially when PE is equivocal and outperforms PE alone.

21 October 2020 in Medical Ultrasonography
Verified
Journal Article
Open access
PDF file
JWJiangfeng Wu
Jiangfeng Wu
YWYunlai Wang
Yunlai Wang
ZWZhengping Wang
Zhengping Wang
The diagnostic accuracy of ultrasound in the detection of foot and ankle fractures: a systematic review and meta-analysis

20 September 2022 in Frontiers in Oncology
Verified
Journal Article
Open access
JWJiangfeng Wu
Jiangfeng Wu
ZZZhijuan Zhou
Zhijuan Zhou
XWXiaoyun Wang
Xiaoyun Wang
YJYun Jin
Yun Jin
ZWZhengping Wang
Zhengping Wang
GJGuilong Jin
Guilong Jin
Purpose: The clinical practice of elastosonography for the detection of salivary gland tumors is still a controversial issue. The objective of this meta-analysis was to evaluate the effect of elastosonography for the diagnosis of salivary gland tumors and to compare the diagnostic value of elastosonography and conventional ultrasound in the diagnosis of salivary gland tumors.Methods: A comprehensive literature search through PubMed, EMBASE, and Cochrane Library was carried out from inception to November 2021. Two researchers independently extracted the data from the enrolled papers using a standard data extraction form. The pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) were calculated to evaluate the diagnostic performance of elastosonography. The Quality Assessment of Diagnostic Accuracy Studies—2 (QUADAS-2) tool was utilized to evaluate the quality of each included study. Meta-DiSc version 1.4, Review Manager 5.3, and StataSE 15 were used.Results: Sixteen studies with a total of 1105 patients with 1146 lesions were included in this meta-analysis. The pooled sensitivity, specificity, PLR, NLR, and DOR of elastosonography for the differentiation between benign and malignant salivary gland tumors were 0.73 (95%CI, 0.66–0.78), 0.64 (95%CI, 0.61–0.67), 2.83 (95%CI, 1.97–4.07), 0.45 (95%CI, 0.32–0.62), and 9.86 (95%CI, 4.49–21.62), respectively, with an AUC of 0.82. Four studies provided data regarding the conventional ultrasound for the differentiation between benign and malignant salivary gland tumors. The pooled sensitivity, specificity, and DOR were 0.62 (95%CI, 0.50–0.73), 0.93 (95%CI, 0.90–0.96), and 25.07 (95%CI, 4.28–146.65), respectively. The meta-regression and subgroup analyses found that assessment methods were associated with significant heterogeneity, and quantitative or semiquantitative elastosonography performed better than the qualitative one.Conclusions: Elastosonography showed a limited value for diagnosing malignant salivary gland tumors; it could be considered as a supplementary diagnostic technology to conventional ultrasound, and quantitative or semiquantitative elastosonography was superior to the qualitative one.