xu yuli

Mrs. xu yuli


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
XYxu yuli
xu yuli
ZLZicheng Liu
Zicheng Liu
JLJingren Lin
Jingren Lin
JZJintao Zhao
Jintao Zhao
NHNguyen Duc Hoa
Nguyen Duc Hoa
JHJin Han
Jin Han
The real-time monitoring of food freshness in refrigerators is of significant importance in detecting potential food spoiling and preventing serious health issues. One method that is commonly reported and has received substantial attention is the discrimination of food freshness via the tracking of volatile molecules. Nevertheless, the ambient environment of low temperature (normally below 4 °C) and high humidity (90% R.H.), as well as poor selectivity in sensing gas species remain the challenge. In this research, an integrated smart gas-tracking device is designed and fabricated. By applying pump voltage on the yttria-stabilized zirconia (YSZ) membrane, the oxygen concentration in the testing chamber can be manually tailored. Due to the working principle of the sensor following the mixed potential behavior, distinct differences in sensitivity and selectivity are observed for the sensor that operated at different oxygen concentrations. Typically, the sensor gives satisfactory selectivity to H2S, NH3, and C2H5OH at the oxygen concentrations of 10%, 30%, and 40%, respectively. In addition, an acceptable response/recovery rate (within 24 s) is also confirmed. Finally, a refrigerator prototype that includes the smart gas sensor is built, and satisfactory performance in discriminating food freshness status of fresh or semi-fresh is verified for the proposed refrigerator prototype. In conclusion, these aforementioned promising results suggest that the proposed integrated smart gas sensor could be a potential candidate for alarming food spoilage.

9 December 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XYxu yuli
xu yuli
XZXueyuan Zhang
Xueyuan Zhang
JLJingren Lin
Jingren Lin
YWYuejun Wu
Yuejun Wu
NHNguyen Duc Hoa
Nguyen Duc Hoa
HJHan Jin
Han Jin
Hexanal detection is essential for real-time monitoring of oil oxidation stability and evaluating health impact. Nevertheless, accurately monitoring hexanal levels in the presence of other volatile organic compounds (VOCs) remains a significant challenge. In this article, we present an In 2 O 3 /SnO 2 composite-based electrochemical gas sensor that offers excellent selectivity for hexanal over other tested VOCs, such as styrene, acetone, and n-hexane, and featured a remarkably low detection limit of approximately 50 parts per billion (ppb). Additionally, a gas sensing device that integrated the aforementioned electrochemical hexanal sensor with blockchain technology was developed to facilitate remote monitoring of hexanal variations. In particular, shuffling technology and digital signatures were utilized to bolster the security of data transmission and access. It turns out that the developed sensing device demonstrated impressive performance in both sensing accuracy and data security, highlighting its potential as a promising solution for remote hexanal monitoring.

20 September 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
XYxu yuli
xu yuli
ZLZicheng Liu
Zicheng Liu
JLJingren Lin
Jingren Lin
JZJintao Zhao
Jintao Zhao
NHNguyen Duc Hoa
Nguyen Duc Hoa
JHJin Han
Jin Han
The real-time monitoring of food freshness in refrigerators is of significant importance in detecting potential food spoiling and preventing serious health issues. One method that is commonly reported and has received substantial attention is the discrimination of food freshness by the tracking of volatile molecules. Nevertheless, the ambient environment of low temperature (normally below 4oC) and high humidity (90% R.H.) as well as poor selectivity in sensing gas species remain the challenge. In this research, an integrated smart gas-tracking device is designed and fabricated. By applying pump voltage on the yttria-stabilized zirconia (YSZ) membrane, the oxygen concentration in the testing chamber can be manually tailored. Due to the working principle of the sensor following the mixed potential behavior, distinct differences in sensitivity and selectivity are observed for the sensor that operated at different oxygen concentrations. Typically, the sensor gives satisfactory selectivity to H2S, NH3, and C2H5OH at the oxygen concentrations of 10%, 30%, and 40%, respectively. In addition, an acceptable response/recovery rate (within 24 s) is also confirmed. Finally, a refrigerator prototype that includes the smart gas sensor is built, and satisfactory performance in discriminating food freshness status of fresh or semi-fresh is verified for the proposed refrigerator prototype. In conclusion, these aforementioned promising results suggest that the proposed integrated smart gas sensor could be a potential candidate for alarming food spoilage.