Vahab Vahdat

Vahab Vahdat

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Applied Soft Computing
Verified
Journal Article
Closed access
KJKamal Jafarian
Kamal Jafarian
VVVahab Vahdat
Vahab Vahdat
SSSeyedmohammad Salehi
Seyedmohammad Salehi
MMMohammadsadegh Mobin
Mohammadsadegh Mobin

1 April 2024 in Cancer Prevention Research
Verified
Journal Article
Open access
PDF file
DEDerek Ebner
Derek Ebner
LRLila J. Jean Finney Rutten
Lila J. Jean Finney Rutten
LMLesley-Ann Miller-Wilson
Lesley-Ann Miller-Wilson
NMNiels Markwat
Niels Markwat
VVVahab Vahdat
Vahab Vahdat
PLPaul J. Limburg
Paul J. Limburg
Colorectal cancer is the second leading cause of cancer-related mortality in adults in the United States. Despite compelling evidence of improved outcomes in colorectal cancer, screening rates are not optimal. This study aimed to characterize colorectal cancer screening trends over the last two decades and assess the impact of various screening modalities on overall colorectal cancer screening rates. Using National Health Interview Survey data from 2005 to 2021, we examined colorectal cancer screening [colonoscopy, multitarget stool DNA (mt-sDNA), fecal occult blood test (FOBT)/fecal immunochemical test, sigmoidoscopy, CT colonography] rates among adults ages 50–75 years (n = 85,571). A pseudo-time-series cross-sectional (pseudo-TSCS) analysis was conducted including a random effects generalized least squares regression model to estimate the relative impact of each modality on changes in colorectal cancer screening rates. Among 50 to 75 year olds, the estimated colorectal cancer screening rate increased from 47.7% in 2005 to 69.9% in 2021, with the largest increase between 2005 and 2010 (47.7%–60.7%). Rates subsequently plateaued until 2015 but increased from 63.5% in 2015 to 69.9% in 2018. This was primarily driven by the increased use of mt-sDNA (2.5% in 2018 to 6.6% in 2021). Pseudo-TSCS analysis results showed that mt-sDNA contributed substantially to the increase in overall screening rates (77.3%; P < 0.0001) between 2018 and 2021. While colorectal cancer screening rates increased from 2005 to 2021, they remain below the 80% goal. The introduction of mt-sDNA, a noninvasive screening test may have improved overall rates. Sustained efforts are required to further increase screening rates to improve patient outcomes and offering a range of screening options is likely to contribute to achieving this goal. Prevention Relevance: This retrospective study highlights the importance of convenient stool-based colorectal cancer screening options to achieve the national goal of 80% for overall colorectal cancer screening rates. Empowering screening-eligible individuals with a choice for their colorectal cancer screening tests is imperative.

16 January 2019 in Health Systems
Verified
Journal Article
Closed access
VVVahab Vahdat
Vahab Vahdat
ANAmir Namin
Amir Namin
RARana Azghandi
Rana Azghandi
JGJacqueline Griffin
Jacqueline Griffin
With greater demand for outpatient services, the importance of patient-centric clinic layout design that improves timeliness of patient care has become more elucidated. In this paper, a novel simulation-optimisation (SO) framework is proposed focusing on the physical and process flows of patients in the design of a paediatric orthopaedic outpatient clinic. A discrete-event simulation model is used to estimate the frequency of movements between clinic units. The resulting information is utilised as input to a mixed integer programming (MIP) model, optimising the clinic layout design. In order to solve the MIP model, Particle Swarm Optimisation (PSO), a metaheuristic approach enhanced with several heuristics is utilised. Finally, the optimisation model outputs are evaluated with the simulation model. The results demonstrate that improvements to the quality of the patient experience can be achieved through incorporating SO methods into the clinic layout design process.

11 July 2023 in Medical Decision Making
Verified
Journal Article
Open access
VVVahab Vahdat
Vahab Vahdat
OAOguzhan Alagoz
Oguzhan Alagoz
JCJing Voon Chen
Jing Voon Chen
LSLeila Saoud
Leila Saoud
BBBijan J. Borah
Bijan J. Borah
PLPaul J. Limburg
Paul J. Limburg
Objectives: Machine learning (ML)–based emulators improve the calibration of decision-analytical models, but their performance in complex microsimulation models is yet to be determined. Methods: We demonstrated the use of an ML-based emulator with the Colorectal Cancer (CRC)-Adenoma Incidence and Mortality (CRC-AIM) model, which includes 23 unknown natural history input parameters to replicate the CRC epidemiology in the United States. We first generated 15,000 input combinations and ran the CRC-AIM model to evaluate CRC incidence, adenoma size distribution, and the percentage of small adenoma detected by colonoscopy. We then used this data set to train several ML algorithms, including deep neural network (DNN), random forest, and several gradient boosting variants (i.e., XGBoost, LightGBM, CatBoost) and compared their performance. We evaluated 10 million potential input combinations using the selected emulator and examined input combinations that best estimated observed calibration targets. Furthermore, we cross-validated outcomes generated by the CRC-AIM model with those made by CISNET models. The calibrated CRC-AIM model was externally validated using the United Kingdom Flexible Sigmoidoscopy Screening Trial (UKFSST). Results: The DNN with proper preprocessing outperformed other tested ML algorithms and successfully predicted all 8 outcomes for different input combinations. It took 473 s for the trained DNN to predict outcomes for 10 million inputs, which would have required 190 CPU-years without our DNN. The overall calibration process took 104 CPU-days, which included building the data set, training, selecting, and hyperparameter tuning of the ML algorithms. While 7 input combinations had acceptable fit to the targets, a combination that best fits all outcomes was selected as the best vector. Almost all of the predictions made by the best vector laid within those from the CISNET models, demonstrating CRC-AIM’s cross-model validity. Similarly, CRC-AIM accurately predicted the hazard ratios of CRC incidence and mortality as reported by UKFSST, demonstrating its external validity. Examination of the impact of calibration targets suggested that the selection of the calibration target had a substantial impact on model outcomes in terms of life-year gains with screening. Conclusions: Emulators such as a DNN that is meticulously selected and trained can substantially reduce the computational burden of calibrating complex microsimulation models. Highlights: Calibrating a microsimulation model, a process to find unobservable parameters so that the model fits observed data, is computationally complex. We used a deep neural network model, a popular machine learning algorithm, to calibrate the Colorectal Cancer Adenoma Incidence and Mortality (CRC-AIM) model. We demonstrated that our approach provides an efficient and accurate method to significantly speed up calibration in microsimulation models. The calibration process successfully provided cross-model validation of CRC-AIM against 3 established CISNET models and also externally validated against a randomized controlled trial.

1 April 2019 in Value in Health
Verified
Journal Article
Closed access
ANAmir T. Namin
Amir T. Namin
MJMohammad S. Jalali
Mohammad S. Jalali
VVVahab Vahdat
Vahab Vahdat
HBHany S. Bedair
Hany S. Bedair
MOMary I. O'COnnor
Mary I. O'COnnor
JIJacqueline A. Isaacs
Jacqueline A. Isaacs

4 April 2018 in Journal of the American Medical Informatics Association
Verified
Journal Article
Closed access
PDF file
VVVahab Vahdat
Vahab Vahdat
JGJacqueline Griffin
Jacqueline Griffin
JSJames E Stahl
James E Stahl
FYF Clarissa Yang
F Clarissa Yang
Objective: Quantify the downstream impact on patient wait times and overall length of stay due to small increases in encounter times caused by the implementation of a new electronic health record (EHR) system. Methods: A discrete-event simulation model was created to examine the effects of increasing the provider-patient encounter time by 1, 2, 5, or 10 min, due to an increase in in-room documentation as part of an EHR implementation. Simulation parameters were constructed from an analysis of 52 000 visits from a scheduling database and direct observation of 93 randomly selected patients to collect all the steps involved in an outpatient dermatology patient care visit. Results: Analysis of the simulation results demonstrates that for a clinic session with an average booking appointment length of 15 min, the addition of 1, 2, 5, and 10 min for in-room physician documentation with an EHR system would result in a 5.2 (22%), 9.8 (41%), 31.8 (136%), and 87.2 (373%) minute increase in average patient wait time, and a 6.2 (12%), 11.7 (23%), 36.7 (73%), and 96.9 (193%) minute increase in length of stay, respectively. To offset the additional 1, 2, 5, or 10 min, patient volume would need to decrease by 10%, 20%, 40%, and >50%, respectively. Conclusions: Small changes to processes, such as the addition of a few minutes of extra documentation time in the exam room, can cause significant delays in the timeliness of patient care. Simulation models can assist in quantifying the downstream effects and help analyze the impact of these operational changes.