To assess spontaneous baroreceptor-heart rate reflex sensitivity during sleep in patients with obstructive sleep apnea syndrome, a condition associated with increased cardiovascular morbidity and mortality and characterized by marked sympathetic activation, which is believed to originate from hypoxic chemoreceptor stimulation, although little is known of other possible mechanisms such as baroreflex impairment. In 11 patients with severe obstructive sleep apnea syndrome (mean+/-SD age 46.8+/-8.1 years, apnea/hypopnea index 67.9+/-19.1 h), who were normotensive or borderline hypertensive during wakefulness by clinic blood pressure measurements, finger blood pressure was monitored beat-by-beat non-invasively (Finapres) at night during polysomnography. Periods of wakefulness and sleep were identified based on electroencephalographic recordings. Baroreflex sensitivity was assessed by the sequence technique, as the slope of the regression line between spontaneous increases or reductions in systolic blood pressure (SBP) and the related lengthening or shortening in the RR interval, occurring over spontaneous sequences of four or more consecutive beats. The number of these sequences was also computed, as an additional index of baroreflex engagement by the spontaneous blood pressure fluctuations. The controls were age-related normotensive or borderline hypertensive subjects without sleep apnea who had been investigated in previous studies; in these subjects blood pressure was recorded intra-arterially over 24 h in ambulatory conditions and spontaneous baroreflex sensitivity was assessed by the sequence technique. In our patients the lowest nocturnal arterial oxygen saturation was 78.6+/-12.1% (mean+/-SD). During sleep, the number of pooled +RR/+SBP and -RR/-SBP sequences per hour was 20.3+/-2.7 per h in patients with sleep apnea and 27.1+/-2.1 /h in controls (means+/-SEM). The average baroreflex sensitivity during sleep periods was 7.04+/-0.8 ms/mmHg in sleep apnea patients and 10.05+/-2.1 ms/mmHg in controls. Both the pooled number of sequences and baroreflex sensitivity values of the sleep apnea patients were significantly (P < 0.01) less than the corresponding night values of control subjects. In the sleep apnea patients, at variance from controls, baroreflex sensitivity did not show any increase during sleep compared with its values during wakefulness (6.9+/-1.0 ms/mmHg). Our data provide evidence that spontaneous baroceptor reflex sensitivity is depressed in severe obstructive sleep apnea syndrome. This suggests that in such patients baroreflex dysfunction and not only chemoreceptor stimulation by hypoxia may be involved in the sympathetic activation which occurs during sleep. Such dysfunction may contribute to the higher rate of cardiovascular morbidity and mortality reported in these patients.
1 August 2002 in American Journal of Respiratory and Critical Care Medicine
The role of the arterial baroreflex in the cardiovascular changes associated with the obstructive sleep apnea syndrome (OSAS), and the effect of nasal continuous positive airway pressure (CPAP) treatment on baroreflex function during sleep are unknown. Baroreflex control of heart rate was studied in 29 normotensive patients with OSAS under no treatment, in 11 age-matched control subjects, and in 10 patients at CPAP withdrawal after 5.5 ± 3.7 (range 3–14) months of treatment. Baroreflex control of heart rate was assessed by “sequence method” analysis of continuous blood pressure recordings (Finapres) obtained during nocturnal polysomnography. In untreated OSAS, baroreflex sensitivity (BRS) was low during wakefulness and non–rapid eye movement (REM) stage 2 sleep compared with control subjects, and correlated inversely with mean lowest SaO2 and the blood pressure increase after apneas. After CPAP treatment, the apnea-hypopnea index was lower, and mean lowest SaO2 higher than before treatment. After CPAP, patients were more bradycardic, blood pressure and its standard deviation decreased as SaO2 improved in non-REM stage 2 sleep, and BRS increased (nocturnal wakefulness: +59%; non-REM stage 2 sleep: +68% over pretreatment values). Our data suggest that baroreflex dysfunction in OSAS may be at least partly accounted for by nocturnal intermittent hypoxemia, and can be reversed by long-term CPAP treatment.
Obstructive sleep apnoeas (OSA) exert immediate marked cardiovascular effects, and may favour the development of systemic and pulmonary hypertension in the long-term. As for the pathogenesis of the acute cardiovascular changes, the first studies high-lighted the role of OSA-induced hypoxia and mechanical changes. However, more recent work pointed to the role played by the arousal reaction terminating OSA, and to the activity of the autonomic nervous system during apnoea and inter-apnoeic phase. As for the pathogenesis of chronic cardiovascular changes, recent findings suggest that the link between OSA and systemic hypertension may be through an abnormal function of the carotid body and underline the importance of chronic intermittent hypoxia versus continuous hypoxia in the development of stable systemic hypertension. On the other hand, OSA do not appear to enhance strongly the development of stable pulmonary hypertension. In this review, we analyze OSA-induced cardiovascular changes with particular emphasis on to the interplay of the possible pathogenic mechanisms involved. Acute OSA-induced cardiovascular alterations during the apnoeic phase appear to result mainly from the mechanical effects of OSA, while during the interapnoeic phase they seem mostly determined by chemical factors (hypoxia, hypercapnia) and by the arousal reaction. In addition, the role of reflex changes elicited by resumption of ventilation should be reconsidered, since lung inflation seems to exert a positive effect on the cardiovascular changes occurring at the end of OSA. This would be in contrast with the inhibitory effects described as "lung inflation reflex", and deserves further study.
1 September 2001 in American Journal of Physiology-Lung Cellular and Molecular Physiology
Elite athletes show a high prevalence of symptoms and signs of asthma, but no study has assessed the acute effects of endurance exercise on airway cells in nonasthmatic athletes. We measured exhaled nitric oxide (NO) and collected samples of induced sputum after 3% NaCl aerosol administration for 20 min in nonasthmatic middle-aged amateur runners after the Fourth Palermo International Marathon and 6–9 wk later (habitual training period) at baseline. After the marathon, exhaled NO (n = 9 subjects) was higher [27 ± 9 parts/billion (ppb)] than at baseline (12 ± 4 ppb;P < 0.0005). Polymorphonuclear neutrophil (PMN) counts in induced sputum were much higher in runners (91.2 ± 3.6% of total cells postmarathon and 78.7 ± 9.1% at baseline) than in sedentary control subjects (9.9 ± 5.9%; P < 0.001). Expression of L-selectin and CD11b/CD18 in sputum PMNs was lower after the race than at baseline and inversely related to the amount of exhaled NO (r = −0.66 and −0.69, respectively; P < 0.05). Our data indicate that sputum PMNs are increased in nonasthmatic runners both after a marathon and at baseline and suggest that NO may modulate exercise-associated inflammatory airway changes.
Because endurance exercise causes release of mediators and growth factors active on the bone marrow, we asked whether it might affect circulating hematopoietic progenitor cells (HPCs) in amateur runners [ n = 16, age: 41.8 ± 13.5 (SD) yr, training: 93.8 ± 31.8 km/wk] compared with sedentary controls ( n = 9, age: 39.4 ± 10.2 yr). HPCs, plasma cortisol, interleukin (IL)-6, granulocyte colony-stimulating factor (G-CSF), and the growth factor fms-like tyrosine kinase-3 (flt3)-ligand were measured at rest and after a marathon (M; n = 8) or half-marathon (HM; n = 8). Circulating HPC counts (i.e., CD34+cells and their subpopulations) were three- to fourfold higher in runners than in controls at baseline. They were unaffected by HM or M acutely but decreased the morning postrace. Baseline cortisol, flt3-ligand, IL-6, and G-CSF levels were similar in runners and controls. IL-6 and G-CSF increased to higher levels after M compared with HM, whereas cortisol and flt3-ligand increased similarly postrace. Our data suggest that increased HPCs reflect an adaptation response to recurrent, exercise-associated release of neutrophils and stress and inflammatory mediators, indicating modulation of bone marrow activity by habitual running.
Baroreflex control of heart rate during sleep (baroreflex sensitivity; BRS) has been shown to be depressed in obstructive sleep apnoea (OSA), and improved after treatment with continuous positive airway pressure (CPAP). Whether CPAP also acutely affects BRS during sleep in uncomplicated severe OSA is still debatable.Blood pressure was monitored during nocturnal polysomnography in 18 patients at baseline and during first-time CPAP application. Spontaneous BRS was analysed by the sequence method, and estimated as the mean sequence slope.CPAP did not acutely affect mean blood pressure or heart rate but decreased cardiovascular variability during sleep. Mean BRS increased slightly during CPAP application (from 6.5±2.4 to 7.5±2.9 ms·mmHg−1), mostly in response to decreasing blood pressure. The change in BRS did not correlate with changes in arterial oxygen saturation or apnoea/hypopnoea index.The small change in baroreflex control of heart rate during sleep at first application of continuous positive airway pressure in severe obstructive sleep apnoea was unrelated to the acute resolution of nocturnal hypoxaemia, and might reflect autonomic adjustments to positive intrathoracic pressure, and/or improved sleep architecture. The small increase in baroreflex control of heart rate during sleep may be of clinical relevance as it was accompanied by reduced cardiovascular variability, which is acknowledged as an independent cardiovascular risk factor.