Dried blood spot (DBS) microsampling is extensively employed in newborn screening (NBS) and neonatal studies. However, the impact of variable neonatal hematocrit (Ht) values on the results can be a source of analytical error, and the use of fixed Ht for calibration (Htcal) is not representative of all neonatal subpopulations. A computational approach based on neonatal demographics was developed and implemented in R® language to propose a strategy using correction factors to address the Ht effect in neonatal DBS partial-spot assays. A rational “tolerance level” was proposed for the Ht effect contribution to the total analytical error and a safe Ht range for neonatal samples, where the correction of concentrations can be omitted. Furthermore, an “alert zone” for a false positive or negative result in NBS was proposed, where the Ht effect has to be considered. Results point toward the use of Htcal values closely representative of populations under analysis and an acceptable level of percentage relative error can be attributed to the Ht effect, diminishing the probability of correction. Overall, the impact of the Ht effect on neonatal studies is important and future work may further investigate this parameter, correlated to other clinical variables potentially affecting results.
Dried blood spots (DBSs) are formed by collecting a small sample of blood on specialized filter paper and allowing it to dry naturally. Various domains of life sciences and drug research extensively use DBSs as a sampling technique. The “Hematocrit (Ht) effect” affects assay bias, and several strategies have been put forth to deal with it, including the correction of quantified concentrations using an appropriate correction factor. The approach was previously applied, following the utilization of an image processing algorithm developed in Matlab® to derive a reliable equation correlating DBS areas to Ht% values. The present work looks more closely at the application of image analysis to the evaluation of Ht in DBS samples. Utilizing image analysis software, DBS samples with known Ht values were processed. Preparation of cards has followed a previously developed protocol for the appropriate formation of uniform area DBSs, irrespective of Ht. The resulting areas showed close resemblance to the respective theoretical areas calculated by applying the correlation equation. Following that, the equation was utilized to determine the Ht values for each sample, and a comprehensive comparison of measured versus calculated Ht was carried out using various statistical approaches for method comparison. The results demonstrated a strong correlation, suggesting the method’s viability in estimating Ht for unknown DBS samples.