Sebastian Helmstetter

Mr. Sebastian Helmstetter

IPEK - Institute of Product Engineering, Karlsruhe Institute of Technology, Karlsruhe, Baden-Württemberg, Germany
orcid
Ph.D. student at Karlsruhe Institute of Technologie (KIT), I...

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Sebastian HelmstetterSebastian Helmstetter
Sebastian Helmstetter
SMSven Matthiesen
Sven Matthiesen
Force-based human posture estimation (FPE) provides a valuable alternative when camera-based human motion capturing is impractical. It offers new opportunities for sensor integration in smart products for patient monitoring, ergonomic optimization and sports science. Due to the interdisciplinary research on the topic, an overview of existing methods and the required expertise for their utilization is lacking. This paper presents a systematic review by the PRISMA 2020 review process. In total, 82 studies are selected (59 machine learning (ML)-based and 23 digital human model (DHM)-based posture estimation methods). The ML-based methods use input data from hardware sensors—mostly pressure mapping sensors—and trained ML models for estimating human posture. The ML-based human posture estimation algorithms mostly reach an accuracy above 90%. DHMs, which represent the structure and kinematics of the human body, adjust posture to minimize physical stress. The required expert knowledge for the utilization of these methods and their resulting benefits are analyzed and discussed. DHM-based methods have shown their general applicability without the need for application-specific training but require expertise in human physiology. ML-based methods can be used with less domain-specific expertise, but an application-specific training of these models is necessary.

7 October 2021 in Forschung im Ingenieurwesen
Verified
Journal Article
Open access
PDF file
Sebastian HelmstetterSebastian Helmstetter
Sebastian Helmstetter
MDMatthias Dörr
Matthias Dörr
RGRené Germann
René Germann
SMSven Matthiesen
Sven Matthiesen
User-centered design focuses on the individual needs of the product users. The aim is to adjust the design of the product according to the requirements of the user and application. Existing methods for evaluation of the perceived usability are often limited to one specific aspect, and it requires a high effort to transfer the respective method to other aspects. A generic process for the evaluation of the perceived usability is missing. This paper presents the generic Usability Study Evaluation Process (USE-Process) that helps product designers to identify and evaluate usability aspects relevant to the suitability of the usage of a product. The process is divided into three sections:1. A structured field study to identify the relevant usability aspects;2. A generic study design for the subjective evaluation of usability aspects under objective and reproducible conditions;3. The use of measurement tools that help to quantify the results of the subjective evaluation.The generic applicability of the process is shown by the example of the evaluation of cordless screwdrivers; several usability aspects were identified, clustered, and evaluated by using subjective evaluation methods and measurement techniques.

1 January 2022
Verified
Conference Paper
Closed access
Sebastian HelmstetterSebastian Helmstetter
Sebastian Helmstetter
SSSusanne Sutschet
Susanne Sutschet
CSCarina Spengler
Carina Spengler
FMFelix Möhler
Felix Möhler
MHMichael Herzog
Michael Herzog
SMSven Matthiesen
Sven Matthiesen
Applied Human Factors and Ergonomics International

1 January 2020
Verified
Conference Paper
Closed access
Sebastian HelmstetterSebastian Helmstetter
Sebastian Helmstetter
RGRené Germann
René Germann
MAMoez Abbes
Moez Abbes
SMSven Matthiesen
Sven Matthiesen
In order to optimize the use of hand/ power tools; user differences such as the influence of user expertise must be considered in product design. Therefore; product-independent non-application-specific variables are needed to objectively capture user expe


Verified
Journal Article
Open access
PDF file
Sebastian HelmstetterSebastian Helmstetter
Sebastian Helmstetter
JSJohannes Sänger
Johannes Sänger
RGRené Germann
René Germann
SMSven Matthiesen
Sven Matthiesen
The interaction between human and machine plays an important role in the design and optimization of human-machine systems. This interaction is characterized by human motion using the technical system. Especially in the field of hand and power tool applications, the motion capture should be performed under the real working condition and without influencing the user. There are already motion tracking systems that allow capturing the motion during the interaction, but there is no mobile motion capture system that allows an individual analysis of the user for biomechanical analysis in the normal work process without influencing him. Therefore, requirements for a motion capture system are derived and a system is presented that meets these requirements. This system consists of two cameras and is based on the pose estimation algorithm OpenPose. The comparison of the presented system and the state-of-the-art system Xsens is performed and based on the measured elbow angle and the wrist position. The results show a very good correspondence between the curve characteristic of the elbow angle and the wrist position of both systems. However, inexplicable values shifting at two different levels still occur, which need to be investigated further. Overall, the presented system shows great potential in terms of mobility and flexibility of the presented system with some weaknesses in the data processing and efficiency. By addressing these weaknesses, the presented system can be used in the analysis and optimization of human-machine systems.