Giovanna Longobardi

Dr. Giovanna Longobardi

Department of Structures for Engineering and Architecture, University of Naples Federico II, Naples, Campania, Italy
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


7 November 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Antonio DavinoAntonio Davino
Antonio Davino
Giovanna LongobardiGiovanna Longobardi
Giovanna Longobardi
Emilia MeglioEmilia Meglio
Emilia Meglio
ADAndrea Dallari
Andrea Dallari
Antonio FormisanoAntonio Formisano
Antonio Formisano
In recent years, new solutions have been studied in order to intervene on existing buildings made of load-bearing masonry or reinforced concrete, both from the seismic point of view and the energy one. In recent years, novel modern techniques using lightweight steel profiles made of steel or aluminium alloys, suitably coupled with heat-insulating panels, have been proposed for requalification of existing building stock. In this paper, the Resisto 5.9 system designed by the Progetto Sisma S.r.l. company was studied and applied as a retrofit system of an existing masonry building. First, this new system for seismic energy requalification of the build-up was presented, describing the basic components and the mounting phases. Subsequently, it has applied to a case study building made of full-brick masonry located in the municipality of Casalecchio di Reno, on the outskirts of Bologna in Northern Italy. Finally, the used coating system was designed for the examined building together with other seismic interventions applied to horizontal structures and foundations. The seismic benefits deriving from using the proposed envelope system and other seismic interventions were proved from the seismic viewpoint by linear dynamic and non-linear static analyses using the TreMuri analysis software. From modal analysis it was seen that the dynamic behaviour of the building with Resisto 5.9 is improved, with an increase of the participating mass (68% instead of 49% of the bare building) of the second mode in the longitudinal direction. Moreover, from pushover analysis it was noticed that the seismic safety factor has passed from 0.51 to 1.05 in the X-direction and from 0.78 to 1.27 in the Y-direction. In conclusion, it was demonstrated that Resisto 5.9, together with all the other planned interventions, is able to accomplish the seismic retrofitting of the studied building.

21 November 2022 in Buildings
Verified
Journal Article
Open access
PDF file
APAssunta Paola Piccolo
Assunta Paola Piccolo
Giovanna LongobardiGiovanna Longobardi
Giovanna Longobardi
Antonio FormisanoAntonio Formisano
Antonio Formisano
The paper discusses the seismic vulnerability of structures susceptible to overcrowding due to their intended use. Specifically, it addresses the analysis towards earthquake actions of a masonry school located in the Municipality of San Giorgio a Cremano, within the neighbourhood of Naples, providing different reinforcement interventions to ensure its seismic consolidation. After a brief introduction, the description of the analysis representative of the current condition of the structure is performed considering both static and seismic actions. The analysis results determine the seismic risk class of the building, allowing to identify its deficiencies, so to design structural consolidation interventions following the standard code indications. In particular, two retrofit techniques, namely, FRP and FRCM systems, are proposed with the purpose to evaluate their benefits to the school building from a seismic viewpoint. Finally, a comparison between the proposed intervention techniques is made to establish which one guarantees the best upgrading of the seismic condition of the examined building.

4 June 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
Giovanna LongobardiGiovanna Longobardi
Giovanna Longobardi
Marius MosoarcaMarius Mosoarca
Marius Mosoarca
AGAurelian Gruin
Aurelian Gruin
AIAlexandru Ion
Alexandru Ion
Antonio FormisanoAntonio Formisano
Antonio Formisano
A large percentage of existing building stock in Italy and throughout Europe is ageing and no longer complies with current regulations, particularly in terms of sustainability. For these reasons, an urgent consolidation plan is needed to ensure an increase in both seismic response and energy response. Indeed, these constructions were built before the actual technical codes, and currently, they are not able to withstand seismic actions. Meanwhile, they are subject to thermal dispersions that could be due to the use of materials with poor properties or construction errors. Among the numerous consolidation techniques, an innovative solution consisting of a coating system has appeared on the construction market in recent decades. It is an integrated solution that simultaneously improves the seismic and energy behaviour of the building. The paper proposes the evaluation of this lightweight and sustainable solution through some experimental tests which were performed at the National Institute for Research and Development in Constructions, located in the city of Timişoara (Romania). The tests were aimed to investigate the out-of-plane behaviour of a masonry wall (1.20 m × 2.40 m × 0.60 m) obtained by combining two smaller panels with mortar and subjecting them to constant vertical force and pushing by an increasing horizontal one. Its response was assessed before and after the application of extruded aluminium alloy base profiles belonging to the system under study.