Hiroshi Watanabe

Dr. Hiroshi Watanabe


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2009 in Surgical and Radiologic Anatomy
Verified
Journal Article
Closed access
PDF file
HWHiroshi Watanabe
Hiroshi Watanabe
MAMomin Mohammad Abdul
Momin Mohammad Abdul
TKTohru Kurabayashi
Tohru Kurabayashi
HAHideki Aoki
Hideki Aoki

7 April 2010 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
YNYoshikazu Nomura
Yoshikazu Nomura
HWHiroshi Watanabe
Hiroshi Watanabe
EHEiichi Honda
Eiichi Honda
TKTohru Kurabayashi
Tohru Kurabayashi

1 March 2011 in European Journal of Radiology
Verified
Journal Article
Closed access
HWHiroshi Watanabe
Hiroshi Watanabe
EHEiichi Honda
Eiichi Honda
ATAkemi Tetsumura
Akemi Tetsumura
TKTohru Kurabayashi
Tohru Kurabayashi

1 January 2010 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
HWHiroshi Watanabe
Hiroshi Watanabe
EHE Honda
E Honda
TKT Kurabayashi
T Kurabayashi
The aim was to investigate the possibility of evaluating the modulation transfer function (MTF) of cone beam CT (CBCT) for dental use using the oversampling method. The CBCT apparatus (3D Accuitomo) with an image intensifier was used with a 100 mum tungsten wire placed inside the scanner at a slight angle to the plane perpendicular to the plane of interest and scanned. 200 contiguous reconstructed images were used to obtain the oversampling line-spread function (LSF). The MTF curve was obtained by computing the Fourier transformation from the oversampled LSF. Line pair tests were also performed using Catphan(R). The oversampling method provided smooth and reproducible MTF curves. The MTF curves revealed that the spatial resolution in the z-axis direction was significantly higher than that in the axial direction. This result was also confirmed by the line pair test. MTF analysis was performed successfully using the oversampling method. In addition, this study clarified that the 3D Accuitomo had high spatial resolution, especially in the z-axis direction.

10 February 2012 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
YNYoshikazu Nomura
Yoshikazu Nomura
HWHiroshi Watanabe
Hiroshi Watanabe
KSKazuya Shirotsu
Kazuya Shirotsu
EHEiichi Honda
Eiichi Honda
YSYasunori Sumi
Yasunori Sumi
TKTohru Kurabayshi
Tohru Kurabayshi

12 July 2006 in Radiation Oncology
Verified
Journal Article
Open access
SOSayako Oota
Sayako Oota
HSHitoshi Shibuya
Hitoshi Shibuya
RYRyo-Ichi Yoshimura
Ryo-Ichi Yoshimura
HWHiroshi Watanabe
Hiroshi Watanabe
MMMasahiko Miura
Masahiko Miura
There is no consensus as to the prognostic model for brachytherapy of tongue carcinoma. This study was designed to evaluate the prognostic factors for local control based on a large population under a unified treatment policy. Between 1970 and 1998, 433 patients with stage II tongue squamous cell carcinoma were treated by low-dose-rate brachytherapy. This series included 277 patients treated with a linear source with a minimum follow-up of 3 years. A spacer was introduced in 1987. The primary local control rates were 85.6%. In the multivariate analysis, an invasive growth pattern was a significant factor for local recurrence. The disease-related survival was influenced by old age and an invasive growth pattern. A spacer lowered mandibular bone complications. The growth pattern was the most important factor for recurrence. Brachytherapy was associated with a high cure rate and the use of spacers brought about good quality of life (QOL).