Marcella Pasculli

Marcella Pasculli


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
GMGiuliana Moffa
Giuliana Moffa
FGFrancesca Galati
Francesca Galati
RMRoberto Maroncelli
Roberto Maroncelli
VRVeronica Rizzo
Veronica Rizzo
FCFederica Cicciarelli
Federica Cicciarelli
Federica PediconiFederica Pediconi
Federica Pediconi
The aim of this prospective study was to compare the diagnostic performance of contrast-enhanced mammography (CEM) versus digital mammography (DM) combined with breast ultrasound (BUS) in women with dense breasts. Between March 2021 and February 2022, patients eligible for CEM with the breast composition category ACR BI-RADS c–d at DM and an abnormal finding (BI-RADS 3-4-5) at DM and/or BUS were considered. During CEM, a nonionic iodinated contrast agent (Iohexol 350 mg I/mL, 1.5 mL/kg) was power-injected intravenously. Images were evaluated independently by two breast radiologists. Findings classified as BI-RADS 1–3 were considered benign, while BI-RADS 4–5 were considered malignant. In case of discrepancies, the higher category was considered for DM+BUS. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated, using histology/≥12-month follow-up as gold standards. In total, 51 patients with 65 breast lesions were included. 59 (90.7%) abnormal findings were detected at DM+BUS, and 65 (100%) at CEM. The inter-reader agreement was excellent (Cohen’s k = 0.87 for DM+BUS and 0.97 for CEM). CEM showed a 93.5% sensitivity (vs. 90.3% for DM+BUS), a 79.4–82.4% specificity (vs. 32.4–35.5% for DM+BUS) (McNemar p = 0.006), a 80.6–82.9% PPV (vs. 54.9–56.0% for DM+BUS), a 93.1–93.3% NPV (vs. 78.6–80.0% for DM+BUS), and a 86.1–87.7% accuracy (vs. 60.0–61.5% for DM+BUS). The AUC was higher for CEM than for DM+BUS (0.865 vs. 0.613 for Reader 1, and 0.880 vs. 0.628, for Reader 2) (p < 0.001). In conclusion, CEM had a better diagnostic performance than DM and BUS alone and combined together in patients with dense breasts.

31 January 2024 in La radiologia medica
Verified
Journal Article
Open access
PDF file
FGFrancesca Galati
Francesca Galati
AMAndrea Marra
Andrea Marra
FCFederica Cicciarelli
Federica Cicciarelli
MPMarcella Pasculli
Marcella Pasculli
RMRoberto Maroncelli
Roberto Maroncelli
Federica PediconiFederica Pediconi
Federica Pediconi
Cryoablation is a minimally invasive technique currently employed in breast cancer care, that uses freeze and thaw cycles to treat benign breast lesions, small breast cancers or focal sites of metastatic disease in patients not eligible for surgery. The final goal of this procedure is to destroy breast cancer cells using extreme cold. In addition, several studies have shown that this technique seems to have an enhancing effect on the immune response, especially by increasing the expression of tumor neoantigens specific to tumor cells, which are then attacked and destroyed. Exploiting this effect, cryoablation in combination with immunotherapy could be the key to treating early-stage breast cancers or patients who are unsuitable for surgery. According to some recent studies, there are other potential tools that could be used to enhance the therapeutic effect of cryoablation, such as FE3O4 nanoparticles or the manipulation of aquaporin expression. The aim of this narrative review is to summarize the current evidence regarding the use, indications, advantages and disadvantages of cryoablation in the treatment of breast cancer.