David Lindström

Dr. David Lindström

orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2022 in Journal of Endovascular Therapy
Verified
Journal Article
Open access
MGMatthew Joe Grima
Matthew Joe Grima
AWAnders Wanhainen
Anders Wanhainen
DLDavid Lindström
David Lindström
Purpose: In situ laser fenestration (ISLF) is a recently introduced technology that offers the potential to perform total endovascular treatment of aortic arch and thoracoabdominal aortic pathologies in the acute setting. This experiment’s aim was to assess ISLF in some currently common aortic endografts and bridging stent-grafts. Materials and Methods: Three different aortic endografts were evaluated: (1) Zenith Alpha, (2) Zenith TX2, and (3) Conformable GORE TAG. Each endograft was submerged in 37°C saline to create fenestrations using the 308 nm CVX-300 Excimer Laser System fitted with a 2.3 mm diameter Turbo-Elite laser atherectomy catheter compatible with a 0.018″ guidewire. Three different 8 mm bridging stent-grafts were evaluated: (1) BeGraft peripheral, (2) BeGraft peripheral plus, and (3) GORE VIABAHN VBX Balloon Expandable. All bridging stent-grafts were deployed and exposed to different balloon sizes and pressures. The ISLFs and bridging stent-grafts were then evaluated for any tears, stenoses, and seal. Results: A laser fenestration was consistently rapidly obtained in the Zenith Alpha and the Zenith TX2 endografts while it proved difficult to achieve a timely fenestration in the C-TAG. No fabric tears were noted in the Zenith Alpha and Zenith TX2 when inflating Armada (Abbott) 8 mm balloon in the fenestrations with pressures up to 15 atmospheres (rated burst pressure) nor when flaring bridging stent-grafts with balloons up to 12 mm in diameter at 10 atmospheres, while major tears were frequently noted in the C-TAG when the Armada 8 mm balloons were inflated. BeGraft Peripheral and BeGraft Peripheral Plus were all firmly attached to the fenestrations showing good seal on manual testing, while every sixth VBX bridging stent-graft displayed poorer attachment to the fenestration before dilatation at high pressure. Commonly, significant stenoses remained in the bridging stent-grafts after dilatation at nominal pressure, which could only be eradicated with high-pressure balloons. Conclusion: In this limited bench-test, Dacron endografts responded well to the ISLF technology. Satisfactory deployment of the bridging stent was noted only after inflation and/or flaring with high-pressure balloons. Further work with different types of commercially-available bridging stent-grafts and endografts to assess the durability of in situ fenestration (ISF) and bridging stents in ISF is recommended. Clinical Impact: This report on experimental in situ laser fenestration provide important insights for clinicians considering using in situ laser fenestration of aortic stentgrafts in vivo. In particular, different laser settings were tested together with a selection of aortic stentgrafts. Also, the target pressure needed in PTA balloons to dilate the fenestrations and any subsequent tears in the fabric were noted. This was followed by deployment of assorted balloon-expandable stentgrafts with estimation of residual stenosis and seal.

13 January 2023 in Annals of Vascular Surgery
Verified
Journal Article
Closed access
ADAnastasia Dean
Anastasia Dean
AWAnders Wanhainen
Anders Wanhainen
KMKevin Mani
Kevin Mani
MKMarek Kuzniar
Marek Kuzniar
MGMatthew Grima
Matthew Grima
DLDavid Lindström
David Lindström

15 March 1996 in Science
Verified
Journal Article
Closed access
PDF file
BSBenjamin C. Schuraytz
Benjamin C. Schuraytz
DLDavid Lindström
David Lindström
LMLuis E. Marín
Luis E. Marín
RMRené R. Martinez
René R. Martinez
DMDavid W. Mittlefehldt
David W. Mittlefehldt
SWSusan J. Wentworth
Susan J. Wentworth
Iridium concentrations in successively smaller subsplits of melt rock and melt breccia from the Chicxulub impact basin were tracked to isolate and identify iridium carrier phases. Iridium-rich particles were isolated from two samples, and a micrometer-scale, silicate-enclosed aggregate of subhedral iridium metal grains was identified in one, confirming earlier reports of iridium at ground zero of the impact at the Cretaceous-Tertiary (K-T) boundary. The aggregate may be either a phase formed after the collision or a relict of the Chicxulub basin-forming meteorite. In either case, its presence indicates that even among the largest impact structures on Earth, meteoritic components may be preserved within the crater.

12 September 2023 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Open access
GAGiuseppe Asciutto
Giuseppe Asciutto
AIAbdulhakim Ibrahim
Abdulhakim Ibrahim
NLNicola Leone
Nicola Leone
SGStefano Gennai
Stefano Gennai
MPMichele Piazza
Michele Piazza
AOAlexander Oberhuber
Alexander Oberhuber
The use of intravascular ultrasound (IVUS) reduces contrast medium usage and radiation exposure during conventional endovascular aneurysm repair (EVAR). The aim of this study was to evaluate safety and efficacy of IVUS in detecting bridging stent graft (bSG) instability during fenestrated and branched EVAR (F/B-EVAR). This was a prospective observational multicentric study. The following outcomes were evaluated: (1) technical success of the IVUS in each bSG, (2) IVUS findings compared with intra-operative angiography, (3) incidence of post-operative computed tomography angiography (CTA) findings not detected with IVUS, and (4) absence of IVUS related adverse events. Target visceral vessel (TVV) instability was defined as any branch/fenestration issues requiring additional manoeuvre or re-intervention. Any IVUS assessment that detected stenosis, kinking, or any geometrical issue of the TVVs were considered to be branch instability. All procedures were performed in ad hoc hybrid rooms. Eighty patients (69% males; median age 72 years; interquartile range 59, 77 years) from four aortic centres treated with F/B-EVAR between January 2019 and September 2021 were included: 70 BEVAR (21 off the shelf; 49 custom made), eight FEVAR (custom made), and two F/B-EVAR (custom made), for a total of 300 potential TVVs. Two TVVs (0.7%) were left unstented and excluded from the analysis. The TVVs could not be accessed with the IVUS catheter in seven cases (2.3%). Furthermore, 17 (5.7%) TVVs could not be examined due to a malfunction of the IVUS catheter. The technical success of the IVUS assessment was 91.9% (274/298), with no IVUS related adverse events. Seven TVVs (2.5%) showed signs of bSG instability by means of IVUS, leading to immediate revisions. The first post-operative CTA at least 30 days after the index procedure was available in 268 out of the 274 TVVs originally assessed by IVUS. In seven of the 268 TVVs (2.6%) a re-intervention became necessary due to bSG instability. This study suggests that IVUS is a safe and potentially valuable adjunct imaging technology for intra-operative detection of TVV instability. Further long term investigations on larger cohorts are required to validate these promising results and to compare IVUS with alternative technologies in terms of efficiency, radiation exposure, procedural time, and costs.

Verified
Journal Article
Open access
PDF file
Andrea XodoAndrea Xodo
Andrea Xodo
Mario D’OriaMario D’Oria
Mario D’Oria
BMBernardo Mendes
Bernardo Mendes
LBLuca Bertoglio
Luca Bertoglio
KMKevin Mani
Kevin Mani
RDRandall DeMartino
Randall DeMartino
The advent and refinement of complex endovascular techniques in the last two decades has revolutionized the field of vascular surgery. This has allowed an effective minimally invasive treatment of extensive disease involving the pararenal and the thoracoabdominal aorta. Fenestrated-branched EVAR (F/BEVAR) now represents a feasible technical solution to address these complex diseases, moving the proximal sealing zone above the renal-visceral vessels take-off and preserving their patency. The aim of this paper was to provide a narrative review on the peri-operative management of patients undergoing F/BEVAR procedures for juxtarenal abdominal aortic aneurysm (JAAA), pararenal abdominal aortic aneurysm (PRAA) or thoracoabdominal aortic aneurism (TAAA). It will focus on how to prevent, diagnose, and manage the complications ensuing from these complex interventions, in order to improve clinical outcomes. Indeed, F/BEVAR remains a technically, physiologically, and mentally demanding procedure. Intraoperative adverse events often require prolonged or additional procedures and complications may significantly impact a patient’s quality of life, health status, and overall cost of care. The presence of standardized preoperative, perioperative, and postoperative pathways of care, together with surgeons and teams with significant experience in aortic surgery, should be considered as crucial points to improve clinical outcomes. Aggressive prevention, prompt diagnosis and timely rescue of any major adverse events following the procedure remain paramount clinical needs.

31 December 2024 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Open access
GJGísli G. Jónsson
Gísli G. Jónsson
AZAlexander Hakon Zielinski
Alexander Hakon Zielinski
MBMárton Berczeli
Márton Berczeli
TRTimothy A Resch
Timothy A Resch
NDNuno Dias
Nuno Dias
DLDavid Lindström
David Lindström
Emergent complex abdominal aortic diseases are challenging to treat. During in situ laser fenestration (ISLF), aortic branches are covered and flow is restored with in situ fenestration of the stent graft, with promising midterm results. This study aimed to expand on the limited body of knowledge of midterm outcomes of ISLF in renovisceral aortic pathology in a multicentre setting. Retrospective pooled data on consecutive ISLF cases of visceral aortic stent grafts undertaken from 2018 - 2023 in three aortic centres were analysed. Technical success was defined as successful vascularisation with a bridging stent graft and acceptable final angiographic series without signs of endoleak related to the bridging stent graft. Target vessel instability was defined as an endoleak related to the bridging stent graft, disconnection, kink, stenosis, occlusion of bridging stent, re-intervention on bridging stent graft, or rupture or death related to the bridging stent graft. A total of 65 ISLFs were performed in 34 patients, with a mean age 74 years. The procedure was acute in 79%, and 35% were ruptures. Pre-stenting was performed on 56 target vessels (86%). Four patients (12%) died within 30 days; all presented with a rupture. Technical success was achieved in 61 of 65 (94%) ISLFs. All failed cannulations were in the renal arteries: three due to difficult angulations and one dissected during cannulation. Median follow up was 16 (interquartile range 5, 22) months. Cumulative survival at six months, one year, and two years was 88%, 80%, and 72%, respectively. In total, six (10%) target vessel instabilities were detected: two (3%) type III endoleaks, and four (7%) stent stenosis; all required re-lining. Freedom from target vessel instability at six months until the end of follow up was 89%. On the latest follow up scan, all successfully deployed ISLF bridging stents were patent (primary assisted patency 100%, 61 of 61) without signs of endoleak type 3. In situ laser fenestration is a promising tool for emergent endovascular procedures in complex anatomies.