Hong Wong

Dr. Hong Wong

Department of Civil and Environmental Engineering Imperial College London,Imperial College Road, London, SW7 2AZ, UK
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2021 in Resources, Conservation and Recycling
Verified
Journal Article
Closed access
Wahid FerdousWahid Ferdous
Wahid Ferdous
AMAllan Manalo
Allan Manalo
RSRafat Siddique
Rafat Siddique
PMPriyan Mendis
Priyan Mendis
YZYan Zhuge
Yan Zhuge
PSPeter Schubel
Peter Schubel

1 June 2006 in Cement and Concrete Research
Verified
Journal Article
Closed access
HWHong Wong
Hong Wong
MHM.K. Head
M.K. Head
NBN.R. Buenfeld
N.R. Buenfeld

1 October 2009 in Magazine of Concrete Research
Verified
Journal Article
Closed access
HWHong Wong
Hong Wong
MZM. Zobel
M. Zobel
NBN.R. Buenfeld
N.R. Buenfeld
RZRobert W. Zimmerman
Robert W. Zimmerman
Available experimental investigations on the effect of the aggregate–paste ‘interfacial transition zone' (ITZ) on mass transport properties of cement-based materials appear to be ambiguous. While some studies have found a deleterious effect of the ITZ, results from others seem to suggest otherwise. The present study examines the relative influences of ITZ and microcracking on the oxygen diffusivity, oxygen permeability and water sorptivity, to further enhance understanding of the links between microstructure and transport properties. Specimens of several neat cement pastes, mortars and concretes were prepared and tested. Variables include water/cement (w/c) ratio (0·3 and 0·5), binder type (CEM I and CEM II with 8% silica fume), curing period (3 and 90 days), aggregate volume fraction (0–70%) and preconditioning temperature (50°C and 105°C). 105°C drying was adapted to induce microcracking. Backscattered electron microscopy and image analysis were applied to characterise the microstructure, in particular the microcracks. It was observed that in all cases, the transport properties of mortars decreased with increasing ITZ fraction. Permeability was far more sensitive to the presence of microcracking and changes in total porosity, compared with diffusivity or sorptivity. However, no critical threshold sand content linked to an ITZ percolation effect was found, even in the deliberately damaged samples. Concretes have about the same diffusivity and sorptivity, but significantly higher permeability than mortars with the same volume fraction of aggregate, despite a lower ITZ fraction. It is argued that the higher permeability of concrete is attributable to more microcracking, and because the microcracks and paste are less tortuous than the equivalent mortar. It is also shown that conventional permeability testing is affected by the sample thickness-to-maximum aggregate size ratio, which may be another factor explaining the disparity between the measured permeability of concretes and mortars.

1 January 2016 in Cement and Concrete Research
Verified
Journal Article
Open access
HLH.X.D. Lee
H.X.D. Lee
HWHong Wong
Hong Wong
NBN.R. Buenfeld
N.R. Buenfeld

1 July 2010 in Corrosion Science
Verified
Journal Article
Closed access
HWHong Wong
Hong Wong
YZY.X. Zhao
Y.X. Zhao
AKA.R. Karimi
A.R. Karimi
NBN.R. Buenfeld
N.R. Buenfeld
WJW.L. Jin
W.L. Jin

27 February 2017 in Materials and Structures
Verified
Journal Article
Open access
PDF file
UAUeli Angst
Ueli Angst
MGMette R. Geiker
Mette R. Geiker
AMAlexander Michel
Alexander Michel
CGChristoph Gehlen
Christoph Gehlen
HWHong Wong
Hong Wong
NBNick Buenfeld
Nick Buenfeld
Although the steel–concrete interface (SCI) is widely recognized to influence the durability of reinforced concrete, a systematic overview and detailed documentation of the various aspects of the SCI are lacking. In this paper, we compiled a comprehensive list of possible local characteristics at the SCI and reviewed available information regarding their properties as well as their occurrence in engineering structures and in the laboratory. Given the complexity of the SCI, we suggested a systematic approach to describe it in terms of local characteristics and their physical and chemical properties. It was found that the SCI exhibits significant spatial inhomogeneity along and around as well as perpendicular to the reinforcing steel. The SCI can differ strongly between different engineering structures and also between different members within a structure; particular differences are expected between structures built before and after the 1970/1980s. A single SCI representing all on-site conditions does not exist. Additionally, SCIs in common laboratory-made specimens exhibit significant differences compared to engineering structures. Thus, results from laboratory studies and from practical experience should be applied to engineering structures with caution. Finally, recommendations for further research are made.