Cheng-Zhong Peng

Prof. Cheng-Zhong Peng


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2016 in Head & Neck
Verified
Journal Article
Closed access
PDF file
CPCheng-Zhong Peng
Cheng-Zhong Peng
ZZZhengxian Zhang
Zhengxian Zhang
JLJibin Liu
Jibin Liu
HCHongyu Chen
Hongyu Chen
XTXiao Tu
Xiao Tu
ZXZhengmei Xue
Zhengmei Xue

10 April 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ZZZeng Zeng
Zeng Zeng
CPCheng-Zhong Peng
Cheng-Zhong Peng
JLJi-Bin Liu
Ji-Bin Liu
YLYi-Wen Li
Yi-Wen Li
HHHong-Feng He
Hong-Feng He
XSXiao-Gang Shen
Xiao-Gang Shen
To evaluate safety and efficacy of one- vs. two-session radiofrequency ablation (RFA) of parathyroid hyperplasia for patients with secondary hyperparathyroidism (SHPT) and to compare the outcome of both methods on hypocalcemia. Patients with secondary hyperparathyroidism underwent ultrasound guided RFA of parathyroid hyperplasia. Patients were alternately assigned to either group 1 (n = 28) with RFA of all 4 glands in one session or group 2 (n = 28) with RFA of 2 glands in a first session and other 2 glands in a second session. Serum parathyroid hormone (PTH), calcium, phosphorus and alkaline phosphatase (ALP) values were measured at a series of time points after RFA. RFA parameters, including operation duration and ablation time and hospitalization length and cost, were compared between the two groups. Mean PTH decreased in group 1 from 1865.18 ± 828.93 pg/ml to 145.72 ± 119.27 pg/ml at 1 day after RFA and in group 2 from 2256.64 ± 1021.72 pg/ml to 1388.13 ± 890.15 pg/ml at 1 day after first RFA and to 137.26 ± 107.12 pg/ml at 1 day after second RFA. Group 1’s calcium level decreased to 1.79 ± 0.31 mmol/L at day 1 after RFA and group 2 decreased to 1.89 ± 0.26 mmol/L at day 1 after second session RFA (P < 0.05). Multivariate analysis showed that hypocalcemia was related to serum ALP. Patients with ALP ≥ 566 U/L had lower calcium compared to patients with ALP < 566 U/L up to a month after RFA (P < 0.05). Group 1’s RFA time and hospitalization were shorter and had lower cost compared with Group 2. US-guided RFA of parathyroid hyperplasia is a safe and effective method for treating secondary hyperparathyroidism. Single-session RFA was more cost-effective and resulted in a shorter hospital stay compared to two sessions. However, patients with two-session RFA had less hypocalcemia, especially those with high ALP.

1 January 2022 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
HCHui-Hui Chai
Hui-Hui Chai
YZYu Zhao
Yu Zhao
ZZZeng Zeng
Zeng Zeng
RYRuizhong Ye
Ruizhong Ye
QHQiao-Hong Hu
Qiao-Hong Hu
CPCheng-Zhong Peng
Cheng-Zhong Peng
Chai HH, et al. Korean J Radiol. 2022 May;23(5):555-565. https://doi.org/10.3348/kjr.2021.0716

18 July 2022 in Frontiers in Public Health
Verified
Journal Article
Open access
HCHui-Hui Chai
Hui-Hui Chai
RYRui-Zhong Ye
Rui-Zhong Ye
LXLin-Fei Xiong
Lin-Fei Xiong
ZXZi-Ning Xu
Zi-Ning Xu
XCXuan Chen
Xuan Chen
CPCheng-Zhong Peng
Cheng-Zhong Peng
Background: Disability has become a global population health challenge. Due to difficulties in self-care or independent living, patients with disability mainly live in community-based care centers or institutions for long-term care. Nonetheless, these settings often lack basic medical resources, such as ultrasonography. Thus, remote ultrasonic robot technology for clinical applications across wide regions is imperative. To date, few experiences of remote diagnostic systems in rural care centers have been reported.Objective: To assess the feasibility of a fifth-generation cellular technology (5G)-based robot-assisted remote ultrasound system in a care center for disabled patients in rural China.Methods: Patients underwent remote robot-assisted and bedside ultrasound examinations of the liver, gallbladder, spleen, and kidneys. We compared the diagnostic consistency and differences between the two modalities and evaluated the examination duration, image quality, and safety.Results: Forty-nine patients were included (21 men; mean age: 61.0 ± 19.0 [range: 19–91] years). Thirty-nine and ten had positive and negative results, respectively; 67 lesions were detected. Comparing the methods, 41 and 8 patients had consistent and inconsistent diagnoses, respectively. The McNemar and kappa values were 0.727 and 0.601, respectively. The mean duration of remote and bedside examinations was 12.2 ± 4.5 (range: 5–26) min and 7.5 ± 1.8 (range: 5–13) min (p < 0.001), respectively. The median image score for original images on the patient side and transmitted images on the doctor side was 5 points (interquartile range: [IQR]: 4.7–5.0) and 4.7 points (IQR: 4.5–5.0) (p = 0.176), respectively. No obvious complications from the examination were reported.Conclusions: A 5G-based robot-assisted remote ultrasound system is feasible and has comparable diagnostic efficiency to traditional bedside ultrasound. This system may provide a unique solution for basic ultrasound diagnostic services in primary healthcare settings.

1 April 2024 in Radiology
Verified
Journal Article
Closed access
WYWenwen Yue
Wenwen Yue
TJTingting Jiang
Tingting Jiang
ZAZisheng Ai
Zisheng Ai
EDErya Deng
Erya Deng
HCHuihui Chai
Huihui Chai
HXHuixiong Xu
Huixiong Xu
US-guided radiofrequency ablation seems to be an efficacious and safe nonsurgical alternative for patients with secondary hyperparathyroidism receiving long-term dialysis treatment.

13 September 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
YZYu-Jing Zhou
Yu-Jing Zhou
LGLe-Hang Guo
Le-Hang Guo
XBXiao-Wan Bo
Xiao-Wan Bo
LSLiping Sun
Liping Sun
YZYi-Feng Zhang
Yi-Feng Zhang
HXHuixiong Xu
Huixiong Xu
Background: Rural general practitioners (GPs) have insufficient diagnostic information to deal with complex clinical scenarios due to the inequality in medical imaging resources in rural and remote communities. The objective of this study is to explore the value of a tele-mentored handheld ultrasound (tele-HHUS) system, allowing GPs to provide ultrasound (US) services in rural and remote communities. Methods: Overall, 708 patients underwent tele-HHUS examination between March and October 2021 and March and April 2022 across thirteen primary hospitals and two tertiary-care general hospitals. All US examinations were guided and supervised remotely in real time by US experts more than 300 km away using the tele-HHUS system. The following details were recorded: location of tele-HHUS scanning, primary complaints, clinical diagnosis, and US findings. The recommendations (referral or follow-up) based on clinical experience alone were compared with those based on clinical experience with tele-HHUS information. Results: Tele-HHUS examinations were performed both in hospital settings (90.6%, 642/708) and out of hospital settings (9.4%, 66/708). Leaving aside routine physical examinations, flank pain (14.2%, 91/642) was the most common complaint in inpatients, while chest distress (12.1%, 8/66) and flank discomfort (12.1%, 8/66) were the most common complaints in out-of-hospital settings. Additionally, the referral rate increased from 5.9% to 8.3% (kappa = 0.202; p = 0.000). Conclusions: The tele-HHUS system can help rural GPs perform HHUS successfully in remote and rural communities. This novel mobile telemedicine model is valuable in resource-limited areas.