Reza Monfaredi

Dr. Reza Monfaredi


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2018 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
RMReza Monfaredi
Reza Monfaredi
KCKevin Cleary
Kevin Cleary
KSKarun Sharma
Karun Sharma

1 January 2018 in Academic Radiology
Verified
Journal Article
Closed access
KCKevin Cleary
Kevin Cleary
SLSunghwan Lim
Sunghwan Lim
CJChanghan Jun
Changhan Jun
RMReza Monfaredi
Reza Monfaredi
KSKarun Sharma
Karun Sharma
DSDan Stoianovici
Dan Stoianovici

1 October 2018
Verified
Conference Paper
Open access
NPNiravkumar A Patel
Niravkumar A Patel
JYJiawen Yan
Jiawen Yan
DLDavid Levi
David Levi
RMReza Monfaredi
Reza Monfaredi
KCKevin Cleary
Kevin Cleary
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
This paper presents a body-mounted, four degree-of-freedom (4-DOF) parallel mechanism robot for image-guided percutaneous interventions. The design of the robot is optimized to be light weight and compact such that it could be mounted to the patient body. It has a modular design that can be adopted for assisting various image-guided, needle-based percutaneous interventions such as arthrography, biopsy and brachytherapy seed placement. The robot mechanism and the control system are designed and manufactured with components compatible with imaging modalities including Magnetic Resonance Imaging (MRI) and Computed Tomography (CT). The current version of the robot presented in this paper is optimized for shoulder arthrography under MRI guidance; a Z-shaped fiducial frame is attached to the robot, providing accurate and repeatable robot registration with the MR scanner coordinate system. Here we present the mechanical design of the manipulator, robot kinematics, robot calibration procedure, and preliminary bench-top accuracy assessment. The bench-top accuracy evaluation of the robotic manipulator shows average translational error of 1.01 mm and 0.96 mm in X and Z axes, respectively, and average rotational error of 3.06 degrees and 2.07 degrees about the X and Z axes, respectively.

11 August 2018 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
RMReza Monfaredi
Reza Monfaredi
IIIulian Iordachita
Iulian Iordachita
EWEmmanuel Wilson
Emmanuel Wilson
RSRaymond Sze
Raymond Sze
KSKarun Sharma
Karun Sharma
KCKevin Cleary
Kevin Cleary

13 August 2024 in Sensors
Verified
Journal Article
Open access
PDF file
RMReza Monfaredi
Reza Monfaredi
ACAlondra Concepcion-Gonzalez
Alondra Concepcion-Gonzalez
JJJose Acosta Julbe
Jose Acosta Julbe
EFElizabeth Fischer
Elizabeth Fischer
GHGabriel Hernandez-Herrera
Gabriel Hernandez-Herrera
COChima Oluigbo
Chima Oluigbo
This review systematically examines the recent research from the past decade on diverse path-planning algorithms tailored for stereotactic neurosurgery applications. Our comprehensive investigation involved a thorough search of scholarly papers from Google Scholar, PubMed, IEEE Xplore, and Scopus, utilizing stringent inclusion and exclusion criteria. The screening and selection process was meticulously conducted by a multidisciplinary team comprising three medical students, robotic experts with specialized knowledge in path-planning techniques and medical robotics, and a board-certified neurosurgeon. Each selected paper was reviewed in detail, and the findings were synthesized and reported in this review. The paper is organized around three different types of intervention tools: straight needles, steerable needles, and concentric tube robots. We provide an in-depth analysis of various path-planning algorithms applicable to both single and multi-target scenarios. Multi-target planning techniques are only discussed for straight tools as there is no published work on multi-target planning for steerable needles and concentric tube robots. Additionally, we discuss the imaging modalities employed, the critical anatomical structures considered during path planning, and the current status of research regarding its translation to clinical human studies. To the best of our knowledge and as a conclusion from this systematic review, this is the first review paper published in the last decade that reports various path-planning techniques for different types of tools for minimally invasive neurosurgical applications. Furthermore, this review outlines future trends and identifies existing technology gaps within the field. By highlighting these aspects, we aim to provide a comprehensive overview that can guide future research and development in path planning for stereotactic neurosurgery, ultimately contributing to the advancement of safer and more effective neurosurgical procedures.

12 September 2014 in Robotica
Verified
Journal Article
Closed access
PDF file
RMReza Monfaredi
Reza Monfaredi
SRS. Mehdi Rezaei
S. Mehdi Rezaei
ATAli Talebi
Ali Talebi
SUMMARY: This paper presents a new observer-based adaptive controller for handling an object withunknowngeometry, center of mass, and inertia using a cooperative robotic system. The cooperative robotic system comprises three Cartesian robots, where robots and the grasped object form a closed-loop kinematic chain. The unknown object is approximated by three virtual links of unknown lengths rigidly attached to one another at the object's center of mass (COM). Due to the unknown COM and unknown inertia of the object, the lengths and inertia of these virtual links are unknown, resulting in kinematic and dynamic uncertainties in the control system. A parameter estimator is proposed to estimate the object's COM to compensate for kinematic uncertainties of the system. Moreover, a new dynamic adaptation law is developed to cope with dynamic uncertainties of the object. The dynamic equations of the cooperative system are transformed from joint space into task space. These task space dynamics are transformed into object space by passively decomposing the dynamics into two decoupled systems, i.e.lockedandshapedsystems. An adaptive controller is developed for the locked system, and the shaped system is controlled by a composite controller based on a PD controller plus a stabilizing damping term. The stability of the proposed controllers is shown using the passivity concept and Lyapunov theorem. Simulation results show that the closed-loop position error asymptotically converges to zero. It is also shown that kinematic and dynamic adaptation parameters converge to real and bounded values respectively.