Angus H. Forster

Dr. Angus H. Forster

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2001 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
AFAngus H. Forster
Angus H. Forster
JHJ Hempenstall
J Hempenstall
ITI Tucker
I Tucker
TRThomas Rades
Thomas Rades

1 March 2001 in Journal of Pharmacy and Pharmacology
Verified
Journal Article
Closed access
PDF file
AFAngus H. Forster
Angus H. Forster
JHJohn Hempenstall
John Hempenstall
TRThomas Rades
Thomas Rades
Indomethacin, lacidipine, nifedipine and tolbutamide are poorly soluble in water and may show dissolution-related low oral bioavailability. This study describes the formulation and characterization of these drugs as glass solutions with the amorphous polymers polyvinylpyrrolidone (PVP) and polyvinylpyrrolidone-co-vinyl acetate by melt extrusion. The extrudates were compared with physical mixtures of drug and polymer. X-ray powder diffraction, thermal analysis, infrared spectroscopy, scanning electron microscopy, HPLC, moisture analysis and dissolution were used to examine the physicochemical properties and chemical stability of the glass solutions prepared by melt extrusion at a 1:1 drug/polymer ratio. Depending on the temperature used, melt extrusion produced amorphous glass solutions, with markedly improved dissolution rates compared with crystalline drug. A significant physicochemical interaction between drug and polymer was found for all extrudates. This interaction was caused by hydrogen bonding (H-bonding) between the carbonyl group of the pyrrole ring of the polymer and a H-donor group of the drug. Indomethacin also showed evidence of H-bonding when physical mixtures of amorphous drug and PVP were prepared. After storage of the extrudates for 4–8 weeks at 25°C/75% relative humidity (RH) only indomethacin/polymer (1:1) extrudate remained totally amorphous. All extrudates remained amorphous when stored at 25°C/< 10% RH. Differences in the physical stability of drug/polymer extrudates may be due to differences in H-bonding between the components.

1 May 2007 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
JPJames E. Patterson
James E. Patterson
MJMichael B. James
Michael B. James
AFAngus H. Forster
Angus H. Forster
RLRobert W. Lancaster
Robert W. Lancaster
JBJames M. Butler
James M. Butler
TRThomas Rades
Thomas Rades

1 September 2005 in Journal of Pharmaceutical Sciences
Verified
Journal Article
Closed access
PDF file
JPJames E. Patterson
James E. Patterson
MJMichael B. James
Michael B. James
AFAngus H. Forster
Angus H. Forster
RLRobert W. Lancaster
Robert W. Lancaster
JBJames M. Butler
James M. Butler
TRThomas Rades
Thomas Rades

1 June 2018 in Vaccine
Verified
Journal Article
Open access
Germain J FernandoGermain J Fernando
Germain J Fernando
JHJulian Hickling
Julian Hickling
CFCesar M. Jayashi Flores
Cesar M. Jayashi Flores
PGPaul Robert Griffin
Paul Robert Griffin
CAChristopher D. Anderson
Christopher D. Anderson
AFAngus H. Forster
Angus H. Forster
Injection using needle and syringe (N&S) is the most widely used method for vaccination, but requires trained healthcare workers. Fear of needles, risk of needle-stick injury, and the need to reconstitute lyophilised vaccines, are also drawbacks. The Nanopatch (NP) is a microarray skin patch comprised of a high-density array of microprojections dry-coated with vaccine that is being developed to address these shortcomings. Here we report a randomised, partly-blinded, placebo-controlled trial that represents the first use in humans of the NP to deliver a vaccine. Healthy volunteers were vaccinated once with one of the following: (1) NPs coated with split inactivated influenza virus (A/California/07/2009 [H1N1], 15 µg haemagglutinin (HA) per dose), applied to the volar forearm (NP-HA/FA), n = 15; (2) NPs coated with split inactivated influenza virus (A/California/07/2009 [H1N1], 15 µg HA per dose), applied to the upper arm (NP-HA/UA), n = 15; (3) Fluvax® 2016 containing 15 µg of the same H1N1 HA antigen injected intramuscularly (IM) into the deltoid (IM-HA/D), n = 15; (4) NPs coated with excipients only, applied to the volar forearm (NP-placebo/FA), n = 5; (5) NPs coated with excipients only applied to the upper arm (NP-placebo/UA), n = 5; or (6) Saline injected IM into the deltoid (IM-placebo/D), n = 5. Antibody responses at days 0, 7, and 21 were measured by haemagglutination inhibition (HAI) and microneutralisation (MN) assays. NP vaccination was safe and acceptable; all adverse events were mild or moderate. Most subjects (55%) receiving patch vaccinations (HA or placebo) preferred the NP compared with their past experience of IM injection with N&S (preferred by 24%). The antigen-vaccinated groups had statistically higher HAI titres at day 7 and 21 compared with baseline (p < 0.0001), with no statistical differences between the treatment groups (p > 0.05), although the group sizes were small. The geometric mean HAI titres at day 21 for the NP-HA/FA, NP-HA/UA and IM-HA/D groups were: 335 (189-593 95% CI), 160 (74-345 95% CI), and 221 (129-380 95% CI) respectively. A similar pattern of responses was seen with the MN assays. Application site reactions were mild or moderate, and more marked with the influenza vaccine NPs than with the placebo or IM injection. Influenza vaccination using the NP appeared to be safe, and acceptable in this first time in humans study, and induced similar immune responses to vaccination by IM injection.

17 March 2020 in PLOS Medicine
Verified
Journal Article
Open access
PDF file
AFAngus H. Forster
Angus H. Forster
KWKatey Witham
Katey Witham
ADAlexandra C I Depelsenaire
Alexandra C I Depelsenaire
MVMargaret Veitch
Margaret Veitch
JWJames Wells
James Wells
Germain J FernandoGermain J Fernando
Germain J Fernando
The Vaxxas high-density microarray patch (HD-MAP) consists of a high density of microprojections coated with vaccine for delivery into the skin. Microarray patches (MAPs) offer the possibility of improved vaccine thermostability as well as the potential to be safer, more acceptable, easier to use, and more cost-effective for the administration of vaccines than injection by needle and syringe (N&S). Here, we report a phase I trial using the Vaxxas HD-MAP to deliver a monovalent influenza vaccine that was to the best of our knowledge the first clinical trial to evaluate the safety, tolerability, and immunogenicity of lower doses of influenza vaccine delivered by MAPs. HD-MAPs were coated with a monovalent, split inactivated influenza virus vaccine containing A/Singapore/GP1908/2015 H1N1 haemagglutinin (HA). Between February 2018 and March 2018, 60 healthy adults (age 18–35 years) in Melbourne, Australia were enrolled into part A of the study and vaccinated with either: HD-MAPs delivering 15 μg of A/Singapore/GP1908/2015 H1N1 HA antigen (A-Sing) to the volar forearm (FA); uncoated HD-MAPs; intramuscular (IM) injection of commercially available quadrivalent influenza vaccine (QIV) containing A/Singapore/GP1908/2015 H1N1 HA (15 μg/dose); or IM injection of H1N1 HA antigen (15 μg/dose). After 22 days’ follow-up and assessment of the safety data, a further 150 healthy adults were enrolled and randomly assigned to 1 of 9 treatment groups. Participants (20 per group) were vaccinated with HD-MAPs delivering doses of 15, 10, 5, 2.5, or 0 μg of HA to the FA or 15 μg HA to the upper arm (UA), or IM injection of QIV. The primary objectives of the study were safety and tolerability. Secondary objectives were to assess the immunogenicity of the influenza vaccine delivered by HD-MAP. Primary and secondary objectives were assessed for up to 60 days post-vaccination. Clinical staff and participants were blind as to which HD-MAP treatment was administered and to administration of IM-QIV-15 or IM-A/Sing-15. All laboratory investigators were blind to treatment and participant allocation. Two further groups in part B (5 participants per group), not included in the main safety and immunological analysis, received HD-MAPs delivering 15 μg HA or uncoated HD-MAPs applied to the forearm. Biopsies were taken on days 1 and 4 for analysis of the cellular composition from the HD-MAP application sites. The vaccine coated onto HD-MAPs was antigenically stable when stored at 40°C for at least 12 months. HD-MAP vaccination was safe and well tolerated; any systemic or local adverse events (AEs) were mild or moderate. Observed systemic AEs were mostly headache or myalgia, and local AEs were application-site reactions, usually erythema. HD-MAP administration of 2.5 μg HA induced haemagglutination inhibition (HAI) and microneutralisation (MN) titres that were not significantly different to those induced by 15 μg HA injected IM (IM-QIV-15). HD-MAP delivery resulted in enhanced humoral responses compared with IM injection with higher HAI geometric mean titres (GMTs) at day 8 in the MAP-UA-15 (GMT 242.5, 95% CI 133.2–441.5), MAP-FA-15 (GMT 218.6, 95% CI 111.9–427.0), and MAP-FA-10 (GMT 437.1, 95% CI 254.3–751.3) groups compared with IM-QIV-15 (GMT 82.8, 95% CI 42.4–161.8), p = 0.02, p = 0.04, p < 0.001 for MAP-UA-15, MAP-FA-15, and MAP-FA-10, respectively. Higher titres were also observed at day 22 in the MAP-FA-10 (GMT 485.0, 95% CI 301.5–780.2, p = 0.001) and MAP-UA-15 (367.6, 95% CI 197.9–682.7, p = 0.02) groups compared with the IM-QIV-15 group (GMT 139.3, 95% CI 79.3–244.5). Results from a panel of exploratory immunoassays (antibody-dependent cellular cytotoxicity, CD4+ T-cell cytokine production, memory B cell (MBC) activation, and recognition of non-vaccine strains) indicated that, overall, Vaxxas HD-MAP delivery induced immune responses that were similar to, or higher than, those induced by IM injection of QIV. The small group sizes and use of a monovalent influenza vaccine were limitations of the study. Influenza vaccine coated onto the HD-MAP was stable stored at temperatures up to 40°C. Vaccination using the HD-MAP was safe and well tolerated and resulted in immune responses that were similar to or significantly enhanced compared with IM injection. Using the HD-MAP, a 2.5 μg dose (1/6 of the standard dose) induced HAI and MN titres similar to those induced by 15 μg HA injected IM. Australian New Zealand Clinical Trials Registry (ANZCTR.org.au), trial ID 108 ACTRN12618000112268/U1111-1207-3550.