Rende Xu

Dr. Rende Xu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
JXJunqiang Xue
Junqiang Xue
LCLu Chen
Lu Chen
HCHao Cheng
Hao Cheng
XSXiaoyue Song
Xiaoyue Song
YSYuekai Shi
Yuekai Shi
JGJunbo Ge
Junbo Ge
Acute myocardial infarction (AMI), one of the most severe and fatal cardiovascular diseases, remains the main cause of mortality and morbidity worldwide. The objective of this study is to investigate the potential biomarkers for AMI based on bioinformatics analysis. A total of 2102 differentially expressed genes (DEGs) were screened out from the data obtained from the gene expression omnibus (GEO) database. Weighted gene co-expression network analysis (WGCNA) explored the co-expression network of DEGs and determined the key module. The brown module was selected as the key one correlated with AMI. Gene Ontology and the Kyoto Encyclopedia of Genes and Genomes pathway enrichment analyses demonstrated that genes in the brown module were mainly enriched in ‘ribosomal subunit’ and ‘Ribosome’. Gene Set Enrichment Analysis revealed that ‘TNFA_SIGNALING_VIA_NFKB’ was remarkably enriched in AMI. Based on the protein–protein interaction network, ribosomal protein L9 (RPL9) and ribosomal protein L26 (RPL26) were identified as the hub genes. Additionally, the polymerase chain reaction (PCR) results indicated that the expression levels of RPL9 and RPL26 were both downregulated in AMI patients compared with controls, in accordance with the bioinformatics analysis. In summary, the identified DEGs, modules, pathways, and hub genes provide clues and shed light on the potential molecular mechanisms of AMI.

7 August 2020 in Journal of Nuclear Cardiology
Verified
Journal Article
Closed access
PDF file
CLChenguang Li
Chenguang Li
RXRende Xu
Rende Xu
KYKang Yao
Kang Yao
JZJie Zhang
Jie Zhang
SCShuguang Chen
Shuguang Chen
JGJunbo Ge
Junbo Ge

31 March 2025 in Theranostics
Verified
Journal Article
Open access
PDF file
YSYuekai Shi
Yuekai Shi
JCJieru Cai
Jieru Cai
LCLu Chen
Lu Chen
HCHao Cheng
Hao Cheng
XSXiaoyue Song
Xiaoyue Song
JGJunbo Ge
Junbo Ge
Background: Doxorubicin (DOX) is a widely employed chemotherapeutic drug, while its clinical use is limited by the lethal cardiotoxicity. Previous studies highlighted the critical role of cardiomyocyte ferroptosis in the pathogenesis of DOX-induced cardiotoxicity (DIC). Androgen-induced gene 1 (AIG1) is perceived as a key regulator of oxidative stress-mediated cell death. Nonetheless, it remains elusive whether AIG1 is involved in the progression of DOX-induced cardiomyocyte ferroptosis and cardiotoxicity.

17 May 2021 in Journal of Interventional Cardiology
Verified
Journal Article
Open access
PDF file
XSXiaoyue Song
Xiaoyue Song
QQQing Qin
Qing Qin
SCShufu Chang
Shufu Chang
RXRende Xu
Rende Xu
MFMingqiang Fu
Mingqiang Fu
JGJunbo Ge
Junbo Ge
Objectives. The present study aimed to investigate the short- and long-term clinical outcomes of self-made polyurethane-covered stents (PU-CS) in patients for the management of coronary artery perforation (CAP) during percutaneous coronary intervention (PCI). Background. Coronary artery perforation is reckoned as a serious complication in PCI and associated with considerable morbidity and mortality. Covered stents have been used for treating the life-threatening CAP during PCI. But in some catheterization laboratories, no commercial CS is immediately available when there is an urgent need for CS to rescue the coronary rupture site. Methods. We retrospectively identified 24 patients who underwent 31 self-made PU-CS implantations due to CAP in Zhongshan Hospital, Fudan University, from June 2015 to January 2020. Results. The total procedural success rate of CS to seal the perforation was 79.2. Nine patients (37.5) developed cardiac tamponade, of which 8 patients (33.3) underwent pericardiocentesis and 4 patients (16.7) underwent cardiac surgeries. Except for 4 cardiac death cases (16.7), none of myocardial infarction (MI), target lesion revascularization (TLR), and stent thrombosis (ST) was reported during hospital stay. Data from 22 patients (91.7) were available at 610.4±420.9 days of follow-up. Major adverse cardiac events (MACE) occurred in 6 patients (27.3), including 5 cases of cardiac death and one TLR case. Conclusions. Self-made PU-CS demonstrates high rates of successful delivery and sealing of severe CAP during PCI. Although the in-hospital mortality remains high after PU-CS implantation, the long-term follow-up shows favorable clinical outcomes, indicating the feasibility of PU-CS in treating CAP.

1 January 2020 in International Journal of Cardiology
Verified
Journal Article
Closed access
QQQing Qin
Qing Qin
SCShufu Chang
Shufu Chang
RXRende Xu
Rende Xu
MFMingqiang Fu
Mingqiang Fu
LCLu Chen
Lu Chen
JGJunbo Ge
Junbo Ge

2 July 2026 in JACC: Case Reports
Verified
Journal Article
Open access
ZDZhenzhen Ding
Zhenzhen Ding
SCShufu Chang
Shufu Chang
MWMengzhang Wu
Mengzhang Wu
QQQing Qin
Qing Qin
RXRende Xu
Rende Xu
JGJunbo Ge
Junbo Ge
Guidewire entrapment during percutaneous coronary intervention (PCI) is a rare but potentially life-threatening complication. Retrieval becomes particularly challenging when the guidewire is trapped beneath a deployed stent. A 72-year-old man with severe calcified left main artery disease underwent PCI. During stent deployment from the left main to the left anterior descending artery, a guidewire in the left circumflex artery became entrapped beneath the stent. After conventional retrieval techniques failed, a bailout strategy using multiple guidewires to entangle and extract the deployed stent was successfully performed. In selected high-risk scenarios, percutaneous retrieval of a deployed stent using a multiwire entanglement technique may be considered when conventional methods fail. Maintaining a high index of recognition for guidewire entrapment is essential throughout the procedure of PCI. Intentional coronary stent retrieval via a multiwire entanglement technique may serve as a feasible bailout strategy for entrapped guidewires.