Wireless wearable insoles are interesting tools to collect gait parameters during daily life activities. However, studies have to be performed specifically for each type of insoles on a big data set to validate the measurement in ecological situations. This study aims to assess the criterion validity and test-retest reliability of gait parameters from wearable insoles compared to motion capture system. Gait of 30 healthy participants was recorded using DSPro® insoles and a motion capture system during overground and treadmill walking at three different speeds. Criterion validity and test-retest reliability of spatio-temporal parameters were estimated with an intraclass correlation coefficient (ICC). For both systems, reliability was found higher than 0.70 for all variables (p < 0.001) except for minimum toe clearance (ICC < 0.50) with motion capture system during overground walking. Regardless of speed and condition of walking, Speed, Cadence, Stride Length, Stride Time and Stance Time variables were validated (ICC > 0.90; p < 0.001). During walking on treadmill, loading time was not validated during slow speed (ICC < 0.70). This study highlights good criterion validity and test-retest reliability of spatiotemporal gait parameters measurement using wearable insoles and opens a new possibility to improve care management of patients using clinical gait analysis in daily life activities.
Running is the basis of many sports and has highly beneficial effects on health. To increase the understanding of running, DSPro® insoles were developed to collect running parameters during tasks. However, no validation has been carried out for running gait analysis. The aims of this study were to assess the test–retest reliability and criterion validity of running gait parameters from DSPro® insoles compared to a motion-capture system. Equipped with DSPro® insoles, a running gait analysis was performed on 30 healthy participants during overground and treadmill running using a motion-capture system. Using an intraclass correlation coefficient (ICC), the criterion validity and test–retest reliability of spatiotemporal parameters were calculated. The test–retest reliability shows moderate to excellent ICC values (ICC > 0.50) except for propulsion time during overground running at a fast speed with the motion-capture system. The criterion validity highlights a validation of running parameters regardless of speeds (ICC > 0.70). This present study validates the good criterion validity and test–retest reliability of DSPro® insoles for measuring spatiotemporal running gait parameters. Without the constraints of a 3D motion-capture system, such insoles seem to be helpful and relevant for improving the care management of active patients or following running performance in sports contexts.