Chen Chen

Dr. Chen Chen

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2020 in Arthritis Research & Therapy
Verified
Journal Article
Open access
PDF file
CCChen Chen
Chen Chen
YCYi Cheng
Yi Cheng
XZXiaoxia Zhu
Xiaoxia Zhu
YCYehua Cai
Yehua Cai
YXYu Xue
Yu Xue
MLMinrui Liang
Minrui Liang
S: Background: Ultrasound is a useful tool to evaluate and quantify skin lesions. Few studies have assessed the criterion validity of skin ultrasound in systemic sclerosis (SSc). The aims of the study were to investigate skin thickness and stiffness using ultrasound and shear wave elastography (SWE) in SSc and to validate skin ultrasound measurements against histological skin thickness. Methods: A total of 22 patients with diffuse cutaneous SSc (dcSSc), 22 with limited cutaneous SSc (lcSSc), and 22 age- and gender-matched healthy controls were enrolled. Skin thickness and stiffness were measured by B-mode ultrasound with SWE imaging on the bilateral fingers and hands. Additional ultrasound evaluation was carried out in 13 patients (9 dcSSc and 4 lcSSc) on their dorsal forearms, followed by skin biopsy conducted in the same skin areas. Correlations between ultrasound measurements and histological skin thickness and modified Rodnan skin score (mRSS) were investigated using Spearman’s correlation. Results: Compared with controls, ultrasound-measured skin thickness and skin stiffness were significantly higher in patients with SSc (p < 0.001) and even higher in those with dcSSc. No clear correlation could be established between ultrasound-determined skin thickness and stiffness at the same site. Ultrasound-measured skin thickness correlated well with histological skin thickness (r = 0.6926, p = 0.009). A weaker association was also observed between histological skin thickness and local mRSS (r = 0.5867, p = 0.050). Conclusions: Ultrasound is a reliable tool for quantifying skin involvement in SSc. Ultrasound-measured skin thickness showed good agreement with histological skin thickness.

17 June 2017 in Metabolic Brain Disease
Verified
Journal Article
Closed access
PDF file
CCChen Chen
Chen Chen
YZYue Zhang
Yue Zhang
HWHui Wu
Hui Wu
YSYi-Min Sun
Yi-Min Sun
YCYe-Hua Cai
Ye-Hua Cai
ZDZheng-Tong Ding
Zheng-Tong Ding

16 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
CCChen Chen
Chen Chen
YYYao Yu
Yao Yu
DCDongxu Chen
Dongxu Chen
CCCanguang Cai
Canguang Cai
YZYannan Zhou
Yannan Zhou
GGGuorong Gu
Guorong Gu
The study aims to develop a decision pathway based on HEAR score and 0 h high-sensitivity cardiac troponin T (hs-cTnT) to safely avoid a second troponin test for suspected non-ST elevation myocardial infarction (NSTEMI) in emergency departments. A HEAR score consists of history, electrocardiogram, age, and risk factors. A HEAR pathway is established using a Bayesian approach based on a predefined safety threshold of NSTEMI prevalence in the rule-out group. In total, 7131 patients were retrospectively enrolled, 582 (8.2%) with index visit NSTEMI and 940 (13.2%) with 180-day major adverse cardiovascular events (MACE). For patients with a low-risk HEAR score (0 to 2) and low 0 h hs-cTnT (<14 ng/L), the HEAR pathway recommends early discharge without further testing. After the HEAR pathway had been applied to rule out NSTEMI, the negative predictive value of index visit NSTEMI was 100.0% (95% CI, 99.8% to 100.0%) and false-negative rate of 180-day MACE was 0.40% (95% CI, 0.18% to 0.87%). Compared with the 0 h hs-cTnT < limit of detection (LoD) strategy (<5 ng/L), the HEAR pathway could correctly reclassify 1298 patients without MACE as low risk and lead to a 18.2% decrease (95% CI, 17.4–19.1%) in the need for a second troponin test. The HEAR pathway may lead to a substantial and safe reduction in repeated troponin test for emergency department patients with suspected NSTEMI.