Huaqing Liu

Mr. Huaqing Liu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2019 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
GFG. Fan
G. Fan
HLHuaqing Liu
Huaqing Liu
ZWZ. Wu
Z. Wu
YLY. Li
Y. Li
CFC. Feng
C. Feng
SHShisheng He
Shisheng He
BACKGROUND AND PURPOSE: 3D reconstruction of a targeted area (“safe” triangle and Kambin triangle) may benefit the viability assessment of transforaminal epidural steroid injection, especially at the L5/S1 level. However, manual segmentation of lumbosacral nerves for 3D reconstruction is time-consuming. The aim of this study was to investigate the feasibility of deep learning–based segmentation of lumbosacral nerves on CT and the reconstruction of the safe triangle and Kambin triangle. MATERIALS AND METHODS: A total of 50 cases of spinal CT were manually labeled for lumbosacral nerves and bones using Slicer 4.8. The ratio of training/validation/testing was 32:8:10. A 3D U-Net was adopted to build the model SPINECT for automatic segmentations of lumbosacral structures. The Dice score, pixel accuracy, and Intersection over Union were computed to assess the segmentation performance of SPINECT. The areas of Kambin and safe triangles were measured to validate the 3D reconstruction. RESULTS: The results revealed successful segmentation of lumbosacral bone and nerve on CT. The average pixel accuracy for bone was 0.940, and for nerve, 0.918. The average Intersection over Union for bone was 0.897 and for nerve, 0.827. The Dice score for bone was 0.945, and for nerve, it was 0.905. There were no significant differences in the quantified Kambin triangle or safe triangle between manually segmented images and automatically segmented images (P > .05). CONCLUSIONS: Deep learning–based automatic segmentation of lumbosacral structures (nerves and bone) on routine CT is feasible, and SPINECT-based 3D reconstruction of safe and Kambin triangles is also validated.

12 January 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
SWShi-Jie Wang
Shi-Jie Wang
HLHuaqing Liu
Huaqing Liu
TYTao Yang
Tao Yang
MHMing-Quan Huang
Ming-Quan Huang
BZBo-Wen Zheng
Bo-Wen Zheng
RJRen Jie
Ren Jie
Improving the assessment of breast imaging reporting and data system (BI-RADS) 4 lesions and reducing unnecessary biopsies are urgent clinical issues. In this prospective study, a radiomic nomogram based on the automated breast volume scanner (ABVS) was constructed to identify benign and malignant BI-RADS 4 lesions and evaluate its value in reducing unnecessary biopsies. A total of 223 histologically confirmed BI-RADS 4 lesions were enrolled and assigned to the training and validation cohorts. A radiomic score was generated from the axial, sagittal, and coronal ABVS images. Combining the radiomic score and clinical-ultrasound factors, a radiomic nomogram was developed by multivariate logistic regression analysis. The nomogram integrating the radiomic score, lesion size, and BI-RADS 4 subcategories showed good discrimination between malignant and benign BI-RADS 4 lesions in the training (AUC, 0.959) and validation (AUC, 0.925) cohorts. Moreover, 42.5% of unnecessary biopsies would be reduced by using the nomogram, but nine (4%) malignant BI-RADS 4 lesions were unfortunately missed, of which 4A (77.8%) and small-sized (<10 mm) lesions (66.7%) accounted for the majority. The ABVS radiomics nomogram may be a potential tool to reduce unnecessary biopsies of BI-RADS 4 lesions, but its ability to detect small BI-RADS 4A lesions needs to be improved.

26 December 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
GFGuoxin Fan
Guoxin Fan
DWDongdong Wang
Dongdong Wang
YLYufeng Li
Yufeng Li
ZXZhipeng Xu
Zhipeng Xu
HWHong Wang
Hong Wang
XLXiang Liao
Xiang Liao
Background: The accurate preoperative identification of decompression levels is crucial for the success of surgery in patients with multi-level lumbar spinal stenosis (LSS). The objective of this study was to develop machine learning (ML) classifiers that can predict decompression levels using computed tomography myelography (CTM) data from LSS patients. Methods: A total of 1095 lumbar levels from 219 patients were included in this study. The bony spinal canal in CTM images was manually delineated, and radiomic features were extracted. The extracted data were randomly divided into training and testing datasets (8:2). Six feature selection methods combined with 12 ML algorithms were employed, resulting in a total of 72 ML classifiers. The main evaluation indicator for all classifiers was the area under the curve of the receiver operating characteristic (ROC-AUC), with the precision–recall AUC (PR-AUC) serving as the secondary indicator. The prediction outcome of ML classifiers was decompression level or not. Results: The embedding linear support vector (embeddingLSVC) was the optimal feature selection method. The feature importance analysis revealed the top 5 important features of the 15 radiomic predictors, which included 2 texture features, 2 first-order intensity features, and 1 shape feature. Except for shape features, these features might be eye-discernible but hardly quantified. The top two ML classifiers were embeddingLSVC combined with support vector machine (EmbeddingLSVC_SVM) and embeddingLSVC combined with gradient boosting (EmbeddingLSVC_GradientBoost). These classifiers achieved ROC-AUCs over 0.90 and PR-AUCs over 0.80 in independent testing among the 72 classifiers. Further comparisons indicated that EmbeddingLSVC_SVM appeared to be the optimal classifier, demonstrating superior discrimination ability, slight advantages in the Brier scores on the calibration curve, and Net benefits on the Decision Curve Analysis. Conclusions: ML successfully extracted valuable and interpretable radiomic features from the spinal canal using CTM images, and accurately predicted decompression levels for LSS patients. The EmbeddingLSVC_SVM classifier has the potential to assist surgical decision making in clinical practice, as it showed high discrimination, advantageous calibration, and competitive utility in selecting decompression levels in LSS patients using canal radiomic features from CTM.

25 October 2022 in Global Spine Journal
Verified
Journal Article
Open access
GFGuoxin Fan
Guoxin Fan
SYSheng Yang
Sheng Yang
JQJiaqi Qin
Jiaqi Qin
LHLongfei Huang
Longfei Huang
YLYufeng Li
Yufeng Li
XLXiang Liao
Xiang Liao
Study Design: Retrospective Cohort Study. Objectives: This study aimed to develop survival prediction models for spinal Ewing’s sarcoma (EWS) based on machine learning (ML). Methods: We extracted the SEER registry’s clinical data of EWS diagnosed between 1975 and 2016. Three feature selection methods extracted clinical features. Four ML algorithms (Cox, random survival forest (RSF), CoxBoost, DeepCox) were trained to predict the overall survival (OS) and cancer-specific survival (CSS) of spinal EWS. The concordance index (C-index), integrated Brier score (IBS) and mean area under the curves (AUC) were used to assess the prediction performance of different ML models. The top initial ML models with best performance from each evaluation index (C-index, IBS and mean AUC) were finally stacked to ensemble models which were compared with the traditional TNM stage model by 3-/5-/10-year Receiver Operating Characteristic (ROC) curves and Decision Curve Analysis (DCA). Results: A total of 741 patients with spinal EWS were identified. C-index, IBS and mean AUC for the final ensemble ML model in predicting OS were .693/0.158/0.829 during independent testing, while .719/0.171/0.819 in predicting CSS. The ensemble ML model also achieved an AUC of .705/0.747/0.851 for predicting 3-/5-/10-year OS during independent testing, while .734/0.779/0.830 for predicting 3-/5-/10-year CSS, both of which outperformed the traditional TNM stage. DCA curves also showed the advantages of the ensemble models over the traditional TNM stage. Conclusion: ML was an effective and promising technique in predicting survival of spinal EWS, and the ensemble models were superior to the traditional TNM stage model.

10 May 2024 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
GFGuoxin Fan
Guoxin Fan
YLYufeng Li
Yufeng Li
DWDongdong Wang
Dongdong Wang
JZJianjin Zhang
Jianjin Zhang
XDXiaokang Du
Xiaokang Du
XLXiang Liao
Xiang Liao
Background: The diagnosis of lumbar spinal stenosis (LSS) can be challenging because radicular pain is not often present in the culprit‐level localization. Accurate segmentation and quantitative analysis of the lumbar dura on radiographic images are key to the accurate differential diagnosis of LSS. The aim of this study is to develop an automatic dura‐contouring tool for radiographic quantification on computed tomography myelogram (CTM) for patients with LSS.Methods: A total of 518 CTM cases with or without lumbar stenosis were included in this study. A deep learning (DL) segmentation algorithm 3‐dimensional (3D) U‐Net was deployed. A total of 210 labeled cases were used to develop the dura‐contouring tool, with the ratio of the training, independent testing, and external validation datasets being 150:30:30. The Dice score (DCS) was the primary measure to evaluate the segmentation performance of the 3D U‐Net, which was subsequently developed as the dura‐contouring tool to segment another unlabeled 308 CTM cases with LSS. Automatic masks of 446 slices on the stenotic levels were then meticulously reviewed and revised by human experts, and the cross‐sectional area (CSA) of the dura was compared.Results: The mean DCS of the 3D U‐Net were 0.905 ± 0.080, 0.933 ± 0.018, and 0.928 ± 0.034 in the five‐fold cross‐validation, the independent testing, and the external validation datasets, respectively. The segmentation performance of the dura‐contouring tool was also comparable to that of the second observer (the human expert). With the dura‐contouring tool, only 59.0% (263/446) of the automatic masks of the stenotic slices needed to be revised. In the revised cases, there were no significant differences in the dura CSA between automatic masks and corresponding revised masks (p = 0.652). Additionally, a strong correlation of dura CSA was found between the automatic masks and corresponding revised masks (r = 0.805).Conclusions: A dura‐contouring tool was developed that could automatically segment the dural sac on CTM, and it demonstrated high accuracy and generalization ability. Additionally, the dura‐contouring tool has the potential to be applied in patients with LSS because it facilitates the quantification of the dural CSA on stenotic slices.

28 October 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
HLHuaqing Liu
Huaqing Liu
PCPeiyi Chen
Peiyi Chen
SZShuxian Zhou
Shuxian Zhou
BWBin Wei
Bin Wei
SDShuwen Deng
Shuwen Deng
LYLi Ye
Li Ye
Antibodies recognized as foreign can elicit anti-drug antibodies that compromise efficacy and safety, making humanness scoring, estimating how human-like a sequence appears, an early, repeated step in antibody development. Widely used scores reduce a variable domain to a single framework-dominated number, leaving the complementarity-determining regions (CDRs), grafted during humanization and diversified by generative models, weakly supervised and rarely audited. Here we introduce IgScope, a 23-million-parameter antibody language model trained from scratch that scores humanness at chain, IMGT-region, and residue resolution; a region-isolated attention module confines attention to within-region pairs, and chimeric-sequence training supplies region-level supervision. On 2.38 million held-out chains, masking all framework tokens leaves CDR accuracy unchanged, and back-mutated murine residues in human frameworks are detected at 93.4% accuracy. At the chain level, IgScope matches the strongest published correlation with clinical anti-drug-antibody incidence (r = − 0.567 , n = 217) and outperforms a same-protocol recomputation. Region-level scoring exposes what chain-level scoring conceals: antibodies designed de novo by four generative models pass whole-chain humanness (0.966–0.988), while their CDRs score far below natural (P < 1e-30) in every chain class. Quality control turns the same resolution to the mirror-image question: in humanized-mouse platforms, whose domains are human by design, IgScope scores the domain as human and, in HUGO-Nano chimeric VHHs, isolates only the FR2 signal of four camelid hallmark residues deliberately retained to stabilize the VHH. IgScope gives antibody humanization a verified foundation and generative design an audit.