Hypertension is a medical condition characterized by high blood pressure, and classifying it into its various stages is crucial to managing the disease. In this project, a novel method is proposed for classifying stages of hypertension using Photoplethysmography (PPG) signals and deep learning models, namely AvgPool_VGG-16. The PPG signal is a non-invasive method of measuring blood pressure through the use of light sensors that measure the changes in blood volume in the microvasculature of tissues. PPG images from the publicly available blood pressure classification dataset were used to train the model. Multiclass classification for various PPG stages were done. The results show the proposed method achieves high accuracy in classifying hypertension stages, demonstrating the potential of PPG signals and deep learning models in hypertension diagnosis and management.
Myelin plays a key role in sending the brain signal from one neuron to another. Without myelin, the brain signals cannot be transmitted properly, so the human brain cannot act according to the situation. Myelin segmentation and quantification is very important for children and adults. Even though many research works are being conducted about myelination, no work is available to segment and quantify myelin from conventional magnetic resonance images (MRI). Some quantitative MRI methods are available which need more time and cost. If it is possible to quantify myelin from conventional MRI, it will be very useful in the medical field. In this work, myelin volume is calculated from different slices of T1-IR-weighted magnetic resonance images that correspond to the basal ganglia and the cerebral peduncle regions of different datasets. The basal ganglia and the cerebral peduncles are the important regions of myelination.
1 April 2017 in Asian Journal of Pharmaceutical and Clinical Research
This paper demonstrates the performance of Erbium doped fiber amplifier(EDFA) and APD receiver in a dynamic wavelength division multiplexing(WDM) system. A four channel 10Gb/s system is taken into consideration and the performance of Erbium doped fiber Amplifier is assessed. The experimental setup consists of a transmitter, a receiver and two intermediate nodes. The transmitted system is tested for Bit Error Rate (BER) and Eye pattern at the receiver. The spectrum is also analysed for different length of fiber. Add Drop Experiment was carried on in which a laser source was switched on and off continuously to assess the transient response of WDM system. Then the Eye Pattern is analysed in which Erbium doped fiber Amplifier system will provide a clear open eye with no degradation of signal.