Michael Marder

Mr. Michael Marder

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Milan StoilovMilan Stoilov
Milan Stoilov
LSLea Stoilov
Lea Stoilov
Norbert EnklingNorbert Enkling
Norbert Enkling
HSHelmut Stark
Helmut Stark
JWJochen Winter
Jochen Winter
Dominik KrausDominik Kraus
Dominik Kraus
The objective of this study was to evaluate the impacts of different sandblasting procedures in acid etching of Ti6Al4V surfaces on osteoblast cell behavior, regarding various physicochemical and topographical parameters. Furthermore, differences in osteoblast cell behavior between cpTi and Ti6Al4V SA surfaces were evaluated. Sandblasting and subsequent acid etching of cpTi and Ti6Al4V discs was performed with Al2O3 grains of different sizes and with varying blasting pressures. The micro- and nano-roughness of the experimental SA surfaces were analyzed via confocal, atomic force and scanning electron microscopy. Surface free energy and friction coefficients were determined. hFOB 1.19 cells were seeded to evaluate adhesion, proliferation and osteoblastic differentiation for up to 12 d via crystal violet assays, MTT assays, ALP activity assays and Alizarin Red staining assays. Differences in blasting procedures had significant impacts on surface macro- and micro-topography. The crystal violet assay revealed a significant inverse relationship between blasting grain size and hFOB cell growth after 7 days. This trend was also visible in the Alizarin Red assays staining after 12 d: there was significantly higher biomineralization visible in the group that was sandblasted with smaller grains (F180) when compared to standard-grain-size groups (F70). SA samples treated with reduced blasting pressure exhibited lower hFOB adhesion and growth capabilities at initial (2 h) and later time points for up to 7 days, when compared to the standard SA surface, even though micro-roughness and other relevant surface parameters were similar. Overall, etched-only surfaces consistently exhibited equivalent or higher adhesion, proliferation and differentiation capabilities when compared to all other sandblasted and etched surfaces. No differences were found between cpTi and Ti6Al4V SA surfaces. Subtle modifications in the blasting protocol for Ti6Al4V SA surfaces significantly affect the proliferative and differentiation behavior of human osteoblasts. Surface roughness parameters are not sufficient to predict osteoblast behavior on etched Ti6Al4V surfaces.

2 May 2022 in Clinical Oral Implants Research
Verified
Journal Article
Open access
Norbert EnklingNorbert Enkling
Norbert Enkling
MMMichael Marder
Michael Marder
SBStefan Bayer
Stefan Bayer
WGWerner Götz
Werner Götz
MSMilan Stoilov
Milan Stoilov
DKDominik Kraus
Dominik Kraus
Objectives: Aim of this study was to compare the soft tissue response to implant abutments made of titanium, zirconia, zirconia veneered with feldspar ceramics and PEEK by various clinical, histological, microbiological, and molecular biological markers in an experimental model.Materials and Methods: A total of 40 experimental one‐piece healing abutments of four different materials were mounted on bone level implants in 20 volunteering patients (split‐mouth design). After a three‐month period of open healing, clinical parameters at the abutments were assessed and adjacent mucosa was sampled for inflammatory cytokine mRNA concentrations and histological analysis by a novel method. In addition, PISF samples were obtained for the analysis of periodonto‐pathogenic bacteria counts and active MMP‐8 levels. Marginal bone level change was measured by intra oral radiographs.Results: Abutments of the different materials did not exhibit significant differences regarding clinical parameters, pathogenic bacteria counts or pro‐inflammatory cytokine concentrations. Likewise, no significant differences were detected regarding soft tissue morphology or bone level change. Compared to titanium abutments, significantly less mononuclear inflammatory cells were detected in the mucosa at abutments made of zirconia veneered with feldspar ceramics.Conclusions: All examined abutment materials exhibited a similar soft tissue response compared to titanium and histological data did not reveal early signs of elevated inflammation caused by PEEK‐ and feldspar‐veneered zirconia abutments. Due to the short observation period and the small sample size, a final conclusion on the long‐term suitability of those abutment materials cannot be drawn. However, based on the presented data, we consider further studies on that subject as appropriate.

12 September 2023 in Journal of Functional Biomaterials
Verified
Journal Article
Open access
PDF file
Milan StoilovMilan Stoilov
Milan Stoilov
RSRamin Shafaghi
Ramin Shafaghi
HSHelmut Stark
Helmut Stark
MMMichael Marder
Michael Marder
Dominik KrausDominik Kraus
Dominik Kraus
Norbert EnklingNorbert Enkling
Norbert Enkling
(1) Background: Primary implant stability is vital for successful implant therapy. This study explores the influence of implant shape, length, and diameter on primary stability in different bone qualities. (2) Methods: Three implant systems (two parallel-walled and one tapered) with various lengths and diameters were inserted into polyurethane foam blocks of different densities (35, 25, 15, and 10 PCF) using standard drilling protocols. Primary stability was assessed through insertion torque (IT) and resonance frequency analysis (RFA). Optimal ranges were defined for IT (25 to 50 Ncm) and RFA (ISQ 60 to 80). A comparison of implant groups was conducted to determine adherence to the optimal ranges. (3) Results: Implant macro-design, -length, and -diameter and bone block density significantly influenced IT and RFA. Optimal IT was observed in 8/40 and 9/40 groups for the parallel-walled implants, while the tapered implant achieved optimal IT in 13/40 groups (within a 25–50 Ncm range). Implant diameter strongly impacted primary stability, with sufficient stability achieved in only one-third of cases despite the tapered implant’s superiority. (4) Conclusions: The findings highlight the need to adapt the drilling protocol based on diverse bone qualities in clinical practice. Further investigations should explore the impact of these adapted protocols on implant outcomes.

25 August 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PJPia-Merete Jervøe-Storm
Pia-Merete Jervøe-Storm
MMMichael Marder
Michael Marder
MHMartin Hagner
Martin Hagner
IMIna Menn
Ina Menn
PMPhilipp Menn
Philipp Menn
SJSøren Jepsen
Søren Jepsen
The aim of this study was to examine the conditions of implants that had been in function for 5–17 years in stage III/IV periodontitis patients of a specialized periodontal practice. There were 83 patients (43 female/40 male, mean age 64.4 (9.69) years), with a total of 213 implants, who participated in the study. Assessments included periodontal and peri-implant probing depths, bleeding and plaque scores, and a radiographic examination. Smoking habits, participation in a supportive care program (SCP), and the Implant Disease Risk Assessment (IDRA) scores were recorded. A total of 44 patients presented with stage III periodontitis, and 39 with stage IV. In all, 85% of patients had adhered to regular SCP. On an implant/patient level, peri-implant health was found in 37.1.7% (79 implants)/24.1% (20 patients), peri-implant mucositis in 58.7% (125 implants)/66.3% (55 patients), and peri-implantitis in 4.2% (9 implants)/9.6% (8 patients). IDRA scores showed 30.5% of implants at moderate and 69.5% at high risk. The present long-term analysis shows a high prevalence of peri-implant disease in patients treated for advanced periodontitis. These findings underline the challenges involved in the long-term maintenance of oral health in stage III/IV periodontitis patients restored with dental implants.

Verified
Journal Article
Open access
PDF file
Milan StoilovMilan Stoilov
Milan Stoilov
RSRamin Shafaghi
Ramin Shafaghi
LSLea Stoilov
Lea Stoilov
HSHelmut Stark
Helmut Stark
MMMichael Marder
Michael Marder
Dominik KrausDominik Kraus
Dominik Kraus
Background: Primary implant stability is a critical factor for successful osseointegration and long-term implant success. This study investigates the impact of drilling protocol modifications on primary stability, considering different bone qualities and implant macro-designs, lengths, and diameters. Material and Methods: Three implant designs—two parallel-walled and one tapered—were tested with diameters ranging from 3.4 to 5.2 mm and lengths from 7.5 to 14.5 mm. Implants were placed in polyurethane foam blocks simulating different bone densities (10, 15, 25, and 35 PCF). A standard drilling protocol was used in all groups, with modifications based on bone quality: overpreparation in dense bone and underpreparation in softer bone. Primary stability was evaluated using insertion torque (IT). The optimal IT range was defined as 25–50 Ncm, based on clinical guidelines for immediate loading. The influence of drilling protocol adaptations on stability parameters was assessed. Results: Insertion torque was primarily influenced by bone density and implant diameter, with implant length playing a minor role. In dense bone (D1, D2), underpreparation improved torque values, especially in smaller implants, while overpreparation reduced them. The highest torques occurred with 5.2 mm implants, sometimes exceeding 80 Ncm. Standard protocols did not consistently achieve optimal torque across implant types. In soft bone (D3), underpreparation—particularly with tapered implants—was modestly beneficial. In very soft bone (D4), none of the protocols reliably reached the desired torque range. Conclusions: Adapting drilling protocols to bone density improves insertion torque, especially with wider implants and in denser bone. Underpreparation is generally more effective than overpreparation. However, in very soft bone, neither implant geometry nor drilling adaptations reliably achieve optimal primary stability, highlighting the need for additional strategies.

2 July 2023 in Clinical Oral Implants Research
Verified
Journal Article
Open access
PJPia-Merete Jervøe-Storm
Pia-Merete Jervøe-Storm
SJSøren Jepsen
Søren Jepsen
MMMichael Marder
Michael Marder
DKDominik Kraus
Dominik Kraus
MSMilan Stoilov
Milan Stoilov
Norbert EnklingNorbert Enkling
Norbert Enkling
Objectives: Previous studies have indicated a progressive internal bacterial colonization of implants and possible implications for peri‐implant bone loss. The aim of this study was to evaluate a decontamination protocol, two disinfectants, and a sealant for their ability to prevent such a colonization.Materials and Methods: Bacterial samples were harvested from the peri‐implant sulcus (external) and following abutment removal from the implant cavity (internal) during routine supportive peri‐implant care in 30 edentulous patients 2 years after they had obtained two implants. In a split‐mouth design, implants were randomly assigned to receive either internal decontamination alone (10% H2O2, brush) or additional placement of either sealant (GS), disinfectant agent (CHX‐varnish) or disinfectant gel (1% CHX‐gel), in the internal cavity before remounting of abutment/suprastructure. Twelve months later, internal and external sampling was repeated. Total bacterial counts (TBCs) were determined using real‐time PCR in a total of 240 samples (eight per patient).Results: Total bacterial counts in the internal cavity significantly reduced overall treatment modalities 1 year after the treatments (4.0 [2.3–6.9]‐fold reduction; p = .000). No significant differences between the four treatment types were found (p = .348). Comparison of internal and external sampling points revealed significant correlation (R2 = .366; p = .000) with systematically higher TBC counts in external samples.Conclusions: Within the limitations of the present study, it can be concluded that the use of disinfectant agents or a sealant did not show an additional benefit in the prevention of internal bacterial colonization of implants compared to a decontamination protocol alone.