Non-destructive 3D micro-computed tomography (microCT) based finite element (microFE) models are used to estimate bone mechanical properties at tissue level. However, their validation remains challenging. Recent improvements in the quantification of displacements in bone tissue biopsies subjected to staged compression, using refined Digital Volume Correlation (DVC) techniques, now provide a full field displacement information accurate enough to be used for microFE validation. In this study, three specimens (two humans and one bovine) were tested with two different experimental set-ups, and the resulting data processed with the same DVC algorithm. The resulting displacement vector field was compared to that predicted by microFE models solved with three different boundary conditions (BC): nominal force resultant, nominal displacement resultant, distributed displacement. The first two conditions were obtained directly from the measurements provided by the experimental jigs, whereas in the third case the displacement field measured by the DVC in the top and bottom layer of the specimen was applied. Results show excellent relationship between the numerical predictions (x) and the experiments (y) when using BC derived from the DVC measurements (UX: y=1.07x-0.002, RMSE: 0.001mm; UY: y=1.03x-0.001, RMSE: 0.001mm; UZ: y=x+0.0002, RMSE: 0.001 mm for bovine specimen), whereas only poor correlation was found using BCs according to experiment set-ups. In conclusion, microFE models were found to predict accurately the vectorial displacement field using interpolated displacement boundary condition from DVC measurement.
1 August 2016 in Journal of the Mechanical Behavior of Biomedical Materials
Computational homogenisation approaches using high resolution images and finite element (FE) modelling have been extensively employed to evaluate the anisotropic elastic properties of trabecular bone. The aim of this study was to extend its application to characterise the macroscopic yield behaviour of trabecular bone. Twenty trabecular bone samples were scanned using a micro-computed tomography device, converted to voxelised FE meshes and subjected to 160 load cases each (to define a homogenised multiaxial yield surface which represents several possible strain combinations). Simulations were carried out using a parallel code developed in-house. The nonlinear algorithms included both geometrical and material nonlinearities. The study found that for tension-tension and compression-compression regimes in normal strain space, the yield strains have an isotropic behaviour. However, in the tension-compression quadrants, pure shear and combined normal-shear planes, the macroscopic strain norms at yield have a relatively large variation. Also, our treatment of clockwise and counter-clockwise shears as separate loading cases showed that the differences in these two directions cannot be ignored. A quadric yield surface, used to evaluate the goodness of fit, showed that an isotropic criterion adequately represents yield in strain space though errors with orthotropic and anisotropic criteria are slightly smaller. Consequently, although the isotropic yield surface presents itself as the most suitable assumption, it may not work well for all load cases. This work provides a comprehensive assessment of material symmetries of trabecular bone at the macroscale and describes in detail its macroscopic yield and its underlying microscopic mechanics.
20 July 2016 in Biomechanics and Modeling in Mechanobiology
The time-independent elastic properties of trabecular bone have been extensively investigated, and several stiffness–density relations have been proposed. Although it is recognized that trabecular bone exhibits time-dependent mechanical behaviour, a property of viscoelastic materials, the characterization of this behaviour has received limited attention. The objective of the present study was to investigate the time-dependent behaviour of bovine trabecular bone through a series of compressive creep–recovery experiments and to identify its nonlinear constitutive viscoelastic material parameters. Uniaxial compressive creep and recovery experiments at multiple loads were performed on cylindrical bovine trabecular bone samples (\(n = 19\)). Creep response was found to be significant and always comprised of recoverable and irrecoverable strains, even at low stress/strain levels. This response was also found to vary nonlinearly with applied stress. A systematic methodology was developed to separate recoverable (nonlinear viscoelastic) and irrecoverable (permanent) strains from the total experimental strain response. We found that Schapery’s nonlinear viscoelastic constitutive model describes the viscoelastic response of the trabecular bone, and parameters associated with this model were estimated from the multiple load creep–recovery (MLCR) experiments. Nonlinear viscoelastic recovery compliance was found to have a decreasing and then increasing trend with increasing stress level, indicating possible stiffening and softening behaviour of trabecular bone due to creep. The obtained parameters from MLCR tests, expressed as second-order polynomial functions of stress, showed a similar trend for all the samples, and also demonstrate stiffening–softening behaviour with increasing stress.
18 April 2016 in Biomechanics and Modeling in Mechanobiology
Trabecular bone has been previously recognized as time-dependent (viscoelastic) material, but the relationships of its viscoelastic behaviour with bone volume fraction (BV/TV) have not been investigated so far. Therefore, the aim of the present study was to quantify the time-dependent viscoelastic behaviour of trabecular bone and relate it to BV/TV. Uniaxial compressive creep experiments were performed on cylindrical bovine trabecular bone samples (\(\textit{n}\,{=}\,13\)) at loads corresponding to physiological strain level of 2000 \({\upmu }{\upvarepsilon }\). We assumed that the bone behaves in a linear viscoelastic manner at this low strain level and the corresponding linear viscoelastic parameters were estimated by fitting a generalized Kelvin–Voigt rheological model to the experimental creep strain response. Strong and significant power law relationships (\(r^2\,{=}\,0.73,\ p\,{<}\,0.001\)) were found between time-dependent creep compliance function and BV/TV of the bone. These BV/TV-based material properties can be used in finite element models involving trabecular bone to predict time-dependent response. For users’ convenience, the creep compliance functions were also converted to relaxation functions by using numerical interconversion methods and similar power law relationships were reported between time-dependent relaxation modulus function and BV/TV.
The creation of scaffolds for cartilage tissue engineering has faced significant challenges in developing constructs that can provide sufficient biomechanical support and offer suitable degradation characteristics. Ideally, such tissue-engineering techniques necessitate the fabrication of scaffolds that mirror the mechanical characteristics of the articular cartilage while degrading safely without damaging the regenerating tissues. The aim of this study was to create porous, biomechanically comparable 3D-printed scaffolds made from Poly(L-lactide-co-glycolide) 85:15 and to assess their degradation at physiological conditions 37 °C in pH 7.4 phosphate-buffered saline (PBS) for up to 56 days. Furthermore, the effect of scaffold degradation on the cell viability and proliferation of human bone marrow mesenchymal stem cells (HBMSC) was evaluated in vitro. To assess the long-term degradation of the scaffolds, accelerated degradation tests were performed at an elevated temperature of 47 °C for 28 days. The results show that the fabricated scaffolds were porous with an interconnected architecture and had comparable biomechanical properties to native cartilage. The degradative changes indicated stable degradation at physiological conditions with no significant effect on the properties of the scaffold and biocompatibility of the scaffold to HBMSC. Furthermore, the accelerated degradation tests showed consistent degradation of the scaffolds even in the long term without the notable release of acidic byproducts. It is hoped that the fabrication and degradation characteristics of this scaffold will, in the future, translate into a potential medical device for cartilage tissue regeneration.